MACX MCR-EX-T-UI-UP 2865654 PHOENIX CONTACT Freely programmable Ex-i temperature transducer with analog outp.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-EX-T-UI-UP 2865654 PHOENIX CONTACT Freely programmable Ex-i temperature transducer with analog outp..

MACX MCR-EX-T-UI-UP

2865654

PHOENIX_CONTACT

Available

Ship on today

Freely programmable Ex-i temperature transducer with analog output and 1 limit value relay, standard configuration, resistance thermometer in 2-, 3-, or 4-wire technology, thermocouples, galvanic isolation, wide-range power supply, screw connection, SIL

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$368.09
2+$360.34
3+$359.46
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width17.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)typ. 5 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Shock15g, according to IEC 60068-2-27
Vibration (operation)5g, accordance to IEC 60068-2-6
Degree of protectionIP20

Input data

Sensor types (RTD) that can be usedPt, Ni, Cu sensors: 2, 3, 4-wire
Sensor types that can be used (TC)B, E, J, K, N, R, S, T, L, U, CA, DA, A1G, A2G, A3G, MG, LG
Temperature measuring range-250 °C ... 2500 °C (Range depending on the sensor type)
Input signal range0 Ω ... 50 kΩ
Potentiometer resistance range0 Ω ... 50 kΩ
Input signal range-1000 mV ... 1000 mV

Output data

Max. voltage output signal± 11 V
Current output signal4 mA ... 20 mA (in the case of SIL; further free configuration without SIL)
Max. current output signal22 mA
Load/output load voltage output≥ 10 kΩ
Load/output load current output≤ 600 Ω (20 mA)
Behavior in the event of a sensor erroraccording to NE 43 or freely configurable
Output nameSwitching output
Contact type1 PDT
Contact materialAgSnO2, hard gold-plated
Maximum switching voltage30 V AC (30 V DC)
Maximum inrush current0.5 A (30 V AC)
1 A (30 V DC)
Mechanical service life1 x 105 cycles

Power supply

Supply voltage range24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Typical current consumption< 50 mA (24 V DC)
Power consumption< 1.5 W

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3
Connection methodScrew connection
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm

General

Maximum transmission error0.1 % (E.g., at Pt 100, 300 K min. span)
Maximum temperature coefficient0.01 %/K
Step response (0–99%)typ. 1000 ms (With SIL)
typ. 700 ms (Without SIL)
Status displayGreen LED (supply voltage, PWR)
Red LED, flashing (line, sensor error, ERR)
Red LED (module error, ERR)
Yellow LED (switching output)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryII
Housing materialPA 66-FR
Colorgreen
DesignationInput/output/power supply
Electrical isolation2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/switching output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationOutput/supply
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category II; pollution degree 2, safe isolation as per EN 61010-1))
ConformanceCE-compliant
ATEXEx II (1) G [Ex ia Ga] IIC
Ex II (1) D [Ex ia Da] IIIC
Ex II 3 G Ex nA nC ic IIC T4 Gc X
IECEx[Ex ia Ga] IIC
[Ex ia Da] IIIC
Ex nA nC ic IIC T4 Gc X
UL, USA / CanadaUL 508 Listed
Functional Safety (SIL)SIL 2

Safety data

Max. internal inductance Linegligible
Max. internal capacitance Ci44 nF
Max. output voltage Uo6 V
Max. output current Io7.4 mA
Max. output power Po11 mW
GroupIIC
Max. external inductivity Lo100 mH
Max. external capacity Co1.3 µF
GroupIIC
Max. external inductivity Lo10 mH
Max. external capacity Co1.7 µF
GroupIIC
Max. external inductivity Lo1 mH
Max. external capacity Co2.6 µF
GroupIIB
Max. external inductivity Lo100 mH
Max. external capacity Co6.8 µF
GroupIIB
Max. external inductivity Lo10 mH
Max. external capacity Co9.2 µF
GroupIIB
Max. external inductivity Lo1 mH
Max. external capacity Co15 µF
Safety-related maximum voltage Um253 V AC/DC

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value2 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value2 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value2 %

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2865654-MACX MCR-EX-T-UI-UPEnglish145 KbytesPHOENIX CONTACT-2865654-MACX MCR-EX-T-UI-UP

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or