MACX MCR-EX-SL-RPSSI-I-UP-SP 2924029 PHOENIX CONTACT Ex-i repeater power supply and input isolating amplifie.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MACX MCR-EX-SL-RPSSI-I-UP-SP 2924029 PHOENIX CONTACT Ex-i repeater power supply and input isolating amplifie..

MACX MCR-EX-SL-RPSSI-I-UP-SP

2924029

PHOENIX_CONTACT

Available

Ship on today

Ex-i repeater power supply and input isolating amplifier, HART Sends fed or active 0/4-20 mA signals from the Ex area to a load (active or passive) to the safe area. Electrical 3-way isolation; SIL 2, wide range power supply.

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$252.46
2+$246.56
3+$243.64
4+$243.15
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width17.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 60 °C (Any mounting position)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Maximum altitude≤ 2000 m
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Degree of protectionIP20

Input data

Signal inputActive current input, intrinsically safe
Current input signal4 mA ... 20 mA
Transmitter supply voltage> 16 V (20 mA)
> 15.3 V (22.5 mA)
Signal inputPassive current input, intrinsically safe
Current input signal0 mA ... 20 mA
4 mA ... 20 mA
Voltage drop< 3.5 V

Output data

Signal outputCurrent output
Voltage output signal1 V ... 5 V (internal resistance, 250 Ω, 0.1%)
Current output signal4 mA ... 20 mA (active)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Transmission Behavior1:1 to input signal
Load/output load current output< 600 Ω (20 mA)
< 525 Ω (22.5 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
≥ 22.5 mA (Cable short-circuit in the input)
Signal outputCurrent output (active and passive)
Voltage output signal0 V ... 5 V (internal resistance, 250 Ω, 0.1%)
Current output signal0 mA ... 20 mA (active)
4 mA ... 20 mA (active)
0 mA ... 20 mA (14 ... 26 V ext. source voltage)
4 mA ... 20 mA (14 ... 26 V ext. source voltage)
Load/output load current output< 600 Ω (20 mA)
< 525 Ω (22.5 mA)
Output ripple< 20 mVrms
Output behavior in the event of an error0 mA (Cable break in the input)
0 mA (Cable short-circuit in the input)

Power supply

DesignationRepeater power supply operation
Supply voltage range24 V ... 230 V AC/DC (-20 %/+10 %, 50/60 Hz)
Max. current consumption< 80 mA (24 V DC / 20 mA)
Power consumption< 1.6 W (24 V DC/ 20 mA)

Connection data

Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm
Connection methodPush-in connection

General

No. of channels1
Maximum transmission error< 0.1 % (of final value)
Transmission error, typical< 0.05 % (of final value)
Maximum temperature coefficient< 0.01 %/K
Step response (10-90%)< 600 µs (for 4 mA ... 20 mA step)
Status displayGreen LED (supply voltage)
Flammability rating according to UL 94V0
Pollution degree2
Overvoltage categoryII
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Emitted interferenceEN 61000-6-4
Housing materialPA 66-FR
Colorgreen
DesignationInput/output/power supply
Electrical isolation300 Vrms (Rated insulation voltage (overvoltage category II; pollution degree 2, safe isolation as per EN 61010-1))
2.5 kV (50 Hz, 1 min., test voltage)
DesignationInput/output
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
DesignationInput/power supply
Electrical isolation375 V (Peak value in accordance with EN 60079-11)
ConformanceCE-compliant, additionally EN 61326
ATEXEx II (1) G [Ex ia Ga] IIC/IIB
Ex II (1) D [Ex ia Da] IIIC
Ex II 3(1) G Ex nA [ia Ga] IIC/IIB T4 Gc
IECEx[Ex ia Ga] IIC/IIB
[Ex ia Da] IIIC
Ex nA [ia Ga] IIC/IIB T4 Gc
UL, USA / CanadaClass I Div 2; IS for Class I, II, III Div 1
Functional Safety (SIL)SIL 2

Data communication (bypass)

HART functionYes
Protocols supportedHART

Safety data

OperationRepeater power supply operation
Max. output voltage Uo25.2 V
Max. output current Io93 mA
Max. output power Po587 mW
GroupIIC
Max. external inductivity Lo2 mH
Max. external capacity Co107 nF
GroupIIB
Max. external inductivity Lo4 mH
Max. external capacity Co820 nF
Safety-related maximum voltage Um253 V AC/DC (Supply terminals)
OperationSignal conditioner operation
Input voltage Ui≤ 30 V
Input current Ii≤ 150 mA
Max. internal inductance Linegligible
Max. internal capacitance Cinegligible

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value1 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value1 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value1 %

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2924029-MACX MCR-EX-SL-RPSSI-I-UP-SPEnglish150 KbytesPHOENIX CONTACT-2924029-MACX MCR-EX-SL-RPSSI-I-UP-SP

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or