IL EIP BK DI8 DO4 2TX-PAC 2897758 PHOENIX CONTACT EtherNet/IP™ bus coupler, 8 inputs, 24 V DC, 4 outputs, 24.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IL EIP BK DI8 DO4 2TX-PAC 2897758 PHOENIX CONTACT EtherNet/IP™ bus coupler, 8 inputs, 24 V DC, 4 outputs, 24..

IL EIP BK DI8 DO4 2TX-PAC

2897758

PHOENIX_CONTACT

Available

Ship on today

EtherNet/IP™ bus coupler, 8 inputs, 24 V DC, 4 outputs, 24 V DC, 500 mA, complete with I/O connectors

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The bus coupler for the EtherNet/IP™ protocol has 4 digital outputs and 8 digital inputs. This package contains all the necessary Inline plugs for connecting the supply and the I/Os.

The Inline terminals can be labeled using pull-out labeling fields. The fields have insert cards that can be labeled individually to suit the application. Additionally, there is the ZBFM-6... Zack marker strip for labeling the terminal points.

Dimensions

Width80 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsSpecfications with connectors

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Net weight320 g
Note on weight specificationswith connectors
Mounting typeDIN rail
Diagnostics messagesShort-circuit / overload of the digital outputs Yes
Sensor supply failure Yes
Failure of the actuator supply Yes

Interfaces

Fieldbus systemEtherNet/IP™
DesignationEtherNet/IP™
Connection methodRJ45 socket, auto negotiation and auto crossing
Transmission speed10/100 MBit/s (half or full duplex (automatic detection))
Transmission physicsEthernet in RJ45 twisted pair
Permissible conductor cross section0.14 mm² ... 0.22 mm² (twisted pair)
Fieldbus systemLokalbus
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s / 2 MBit/s (Automatic detection, no combined system)

System limits of the bus coupler

DesignationSystem limits of the bus coupler
Amount of process datamax. 512 Byte (per station)
Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 61 (on board I/Os are two devices)
Number of devices with parameter channelmax. 8
Number of supported branch terminals with remote bus branch0

Power supply for module electronics

Connection methodSpring-cage connection
DesignationBus coupler supply UBC; Communications power UL (7.5 V) and the analog supply UANA (24 V) are generated from the bus coupler supply.
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Supply currenttyp. 70 mA
Current consumptionmax. 0.98 A (from UBK)
Power losstyp. 3 W (entire device)
Communications power UL7.5 V DC
Current consumption0.8 A
Power consumptiontyp. 1.7 W

Inline potentials

Communications power UL7.5 V DC ±5 %
Power supply at ULmax. 0.8 A DC
Main circuit supply UM24 V DC
Supply voltage range UM19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at UMmax. 8 A DC (Sum of UM + US)
Current consumption from UMmax. 8 A DC
Segment supply voltage US24 V DC
Supply voltage range US19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at USmax. 8 A DC (Sum of UM + US)
Current consumption from USmax. 8 A DC
I/O supply voltage UANA24 V DC
Supply voltage range UANA19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at UANAmax. 0.5 A DC

Digital inputs

Input nameDigital inputs
Connection methodInline connector
2, 3-wire
Number of inputs8 (EN 61131-2 type 1)
Typical response timeapprox. 500 µs
Protective circuitProtection against polarity reversal Suppressor diode
Input voltage24 V DC
Input voltage range "0" signal-30 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input current at UINtyp. 3 mA
Typical input current per channeltyp. 3 mA
Delay at signal change from 0 to 11.2 ms
Delay at signal change from 1 to 01.2 ms

Digital outputs

Output nameDigital outputs
Connection methodInline connector
2, 3-wire
Number of outputs4
Protective circuitShort-circuit and overload protection Free running circuit
Output voltage24 V DC -1 V (At nominal current)
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Maximum output current per module / terminal block2 A
Maximum output current per module2 A
Nominal load, inductive12 VA (1.2 H; 48 Ω)
Nominal load, lamp12 W
Nominal load, ohmic12 W

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2897758-IL EIP BK DI8 DO4 2TX-PACEnglish137 KbytesPHOENIX CONTACT-2897758-IL EIP BK DI8 DO4 2TX-PAC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or