MINI-PS- 48- 60DC/24DC/1 2866271 PHOENIX CONTACT DC/DC converters View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MINI-PS- 48- 60DC/24DC/1 2866271 PHOENIX CONTACT DC/DC converters

MINI-PS- 48- 60DC/24DC/1

2866271

PHOENIX_CONTACT

DC/DC converters

More details


Power Supplies (PS)

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $211.01
Unit price: $211.01

Quantity Price
1+$211.01
2+$185.43
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2866271
Packing unit1 pc
Catalog pagePage 257 (C-4-2017)
GTIN4017918960919
Weight per Piece (excluding packing)200.000 g
Custom tariff number85044030
Country of originCN (China)

Dimensions

Width22.5 mm
Height99 mm
Depth107 mm

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. permissible relative humidity (operation)≤ 95 % (at 25 °C, non-condensing)

Input data

Nominal input voltage range48 V DC ... 60 V DC
Input voltage range36 V DC ... 75 V DC
Frequency range DC0 Hz
Current consumption0.6 A (48 V DC)
0.5 A (60 V DC)
Inrush surge current< 15 A (typical)
Mains bufferingtyp. 15 ms (48 V DC)
typ. 20 ms (60 V DC)
Input fuse3.15 A (slow-blow, internal)

Output data

Nominal output voltage24 V DC ±1 %
Setting range of the output voltage (USet)22.5 V DC ... 28.5 V DC (> 24 V DC, constant capacity restricted)
Nominal output current (IN)1 A (-25 °C ... 60 °C)
Derating60 °C ... 70 °C (2.5%/K)
Connection in parallelYes, for assembling redundant systems and increasing efficiency
Connection in seriesyes
Residual ripple< 40 mVPP
Output power24 W
Typical response time< 0.5 s
Peak switching voltages nominal load< 50 mVPP(20 MHz)
Maximum power dissipation in no-load condition< 1.2 W
Power loss nominal load max.< 5 W

General

Net weight0.2 kg
Operating voltage displayGreen LED
Efficiency> 85 % (at 60 V DC and nominal values)
Insulation voltage input/output1.5 kV (type test)
1 kV (routine test)
Protection classII
Degree of protectionIP20
MTBF (IEC 61709, SN 29500)
> 1147000 h (40 °C)
Mounting positionhorizontal DIN rail NS 35, EN 60715
Assembly instructionsalignable: horizontally 0 mm, vertically 50 mm

Connection data, input

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3

Connection data, output

Connection methodPluggable screw connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Stripping length7 mm
Screw threadM3

Signaling

Output nameDC OK active
Output descriptionUOUT> 21.5 V: High signal
Maximum switching voltage≤ 24 V DC
Output voltage+ 24 V (Signal)
Continuous load current≤ 20 mA
Status display"DC OK" LED green
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.14
Tightening torque, min0.5 Nm
Tightening torque max0.6 Nm
Screw threadM3

Standards and Regulations

Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Noise emissionEN 55011 (EN 55022)
Noise immunityEN 61000-6-2:2005
Connection in acc. with standardCUL
Standards/regulationsEN 61000-4-2
Contact discharge8 kV (Contact discharge)
Standards/regulationsEN 61000-4-3
Frequency range80 MHz ... 3 GHz
Test field strength10 V/m
Standards/regulationsEN 61000-4-4
CommentsLevel 2 - asymmetrical cable to ground
Standards/regulationsEN 61000-6-3
EN 61000-4-6
Frequency range0.15 MHz ... 80 MHz (10 V)
Standards/regulationsEN 61000-4-11
Low Voltage DirectiveConformance with LV directive 2006/95/EC
Standard - Electrical safetyEN 60950-1/VDE 0805 (SELV)
Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installationsEN 50178/VDE 0160 (PELV)
Standard - Safe isolationDIN VDE 0100-410
DIN VDE 0106-101
UL approvalsUL/C-UL listed UL 508
UL/C-UL Recognized UL 60950-1
UL ANSI/ISA-12.12.01 Class I, Division 2, Groups A, B, C, D (Hazardous Location)
Rail applicationsEN 50121-4

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 25;
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.