PLC-INTERFACE for railway applications, consisting of bas - PHOENIX CONTACT - PLC-RSP-230UC/21-21AU/RWF - 2968001 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-INTERFACE for railway applications, consisting of bas - PHOENIX CONTACT - PLC-RSP-230UC/21-21AU/RWF - 2968001






Ship on today

PLC-INTERFACE for railway applications, consisting of basic terminal block with spring-cage connection and plug-in miniature relay with multi-layer gold contact, range: 0.75 x UN to 1.15 x UN, nominal input frequency 16.7 Hz, 2 PDTs, input voltage 230 V AC

More details



* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

Price: $34.68
*This price is per unit and is the net value (not including taxes if applicable).
Up to 35% discount for registered clients.

Request a quote
How it Works

How does the quotation request work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with our price proposals
4 You can directly process the order for the quotation

There are several options for payment
- Credit card
- Wire Transfer
- PayPal

More info


Width14 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN230 V AC
Input voltage range in reference to UNsee diagram
Mains frequency16.67 Hz
Typical input current at UN4.8 mA (with AC)
Typical response time20 ms
Typical release time60 ms
Coil voltage110 V DC
Protective circuitBridge rectifier
Operating voltage displayYellow LED

Contact side

Contact type2 PDT
Contact materialAgNi, hard gold-plated
Maximum switching voltage30 V AC
36 V DC
Minimum switching voltage100 mV
Min. switching current1 mA
Maximum inrush current50 mA
Limiting continuous current50 mA
Interrupting rating (ohmic load) max.1.2 W (at 24 V DC)
Notethe following values are applicable if a gold layer is destroyed
Maximum switching voltage250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum switching voltage5 V AC/DC
Limiting continuous current6 A
Maximum inrush current8 A
Min. switching current10 mA
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
85 W (at 48 V DC)
60 W (at 60 V DC)
44 W (at 110 V DC)
60 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity in acc. with DIN VDE 0660/IEC 609472 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
2 A (at 24 V, AC15)
2 A (at 120 V, AC15)
2 A (at 250 V, AC15)


Test voltage relay winding/relay contact6 kV
Operating mode100% operating factor
Degree of protectionRT III (Relay)
IP20 (Relay socket)
Mechanical service lifeApprox. 3 x 107 cycles
Flammability rating according to UL 94V0
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsIEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulation6 kV/Basic isolation
Rated insulation voltage250 V AC
Pollution degree2
Overvoltage categoryIII
Mounting positionany
Assembly instructionsIn rows with zero spacing

Connection data input side

Connection nameCoil side
Connection methodSpring-cage connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

PDF of PLC-INTERFACE for railway applications, consisting of bas - PHOENIX CONTACT - PLC-RSP-230UC/21-21AU/RWF - 2968001

PHOENIX CONTACT-2968001-PLC-RSP-230UC/21-21AU/RWFEnglish82 KbytesPHOENIX CONTACT-2968001-PLC-RSP-230UC/21-21AU/RWF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait

* Required fields