Compact signaling system for mobile phone networks to monitor digital values as well as to switch relay outputs remotely. Communication is via the ODP protocol to an ODP server using GPRS. Supply voltage range of 93 V ... 250 V AC.

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$637.42
2+$633.59
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width72 mm
Height90 mm
Depth62 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C (for derating, see technical documentation)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)0 % ... 95 %
Altitude2000 m
Degree of protectionIP30

General

Standards/regulationsEN 50121-4
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016)
Net weight257.4 g
Housing materialPolycarbonate
ConformanceCE-compliant
ATEXEx II 3 G Ex nA nC IIC T4 Gc X (Please follow the special installation instructions in the documentation!)
UL, USA / CanadacULus listed UL 508

Power supply

Supply voltage range93 V AC ... 250 V AC (48 Hz ... 62 Hz)
Typical current consumption30 mA (230 V AC)
10 mA (stand by)

Serial interface

Interface 1USB 2.0
Connection methodMini-USB type B, 5-pos.
Transmission length≤ 3 m (only for configuration and diagnostics)

Radio interface

Interface descriptionGSM
Frequency850 MHz (2 W (EGSM))
900 MHz (2 W (EGSM))
1800 MHz (1 W (EGSM))
1900 MHz (1 W (EGSM))
EDGEMultislot Class 10

Digital outputs

Output nameRelay output
Number of outputs4
Contact typeN/O contact
Minimum switching voltage5 V
Maximum switching voltage250 V AC
125 V DC
Limiting continuous current5 A
Switching capacity750 VA
Electrical service life150000 cycles (5 A / 30 V DC)
150000 cycles (3 A / 120 V AC)
30000 cycles (5 A/250 V AC)

Digital inputs

Description of the inputDigital input
Number of inputs4
Switching level "0" signal0 V AC ... 50 V AC
Switching level "1" signal90 V AC ... 250 V AC

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2903808-TC MOBILE I/O X300 ACEnglish245 KbytesPHOENIX CONTACT-2903808-TC MOBILE I/O X300 AC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or