Combination of pluggable type 2 arrester and residual current circuit breaker(RCD switch) for 3-phase power supply networks (5-conductor system: L1, L2, L3,N, PE).

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$245.71
2+$239.95
3+$237.10
4+$236.55
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Height90 mm
Width121 mm
Depth76 mm
Horizontal pitch7 Div.

Ambient conditions

Degree of protectionIP20
Ambient temperature (operation)-25 °C ... 40 °C
Ambient temperature (storage/transport)-40 °C ... 60 °C
Altitude≤ 2000 m (amsl (above mean sea level))
Permissible humidity (operation)5 % ... 95 %

General

IEC power supply systemTN-S
TT
Housing materialPBT-FR
Flammability rating according to UL 94V-0
Colorlight gray
Mounting typeDIN rail: 35 mm
TypeDIN rail module, two-section, divisible
Number of positions4
Surge protection fault messageoptical
Direction of action3L-N & N-PE

Protective circuit

IEC test classificationII
T2
EN typeT2
Nominal voltage UN240/415 V AC (TN-S)
Maximum continuous operating voltage UC (L-N)350 V AC
Maximum continuous operating voltage UC (N-PE)264 V AC
Nominal frequency fN50 Hz (60 Hz)
Rated load current IL40 A
Residual current IPE≤ 1 µA
Max. discharge current Imax (8/20) µs30 kA
Nominal discharge current In (8/20) µs20 kA
Front of wave sparkover voltage at 6 kV (1.2/50) µs (N-PE)≤ 1.7 kV
Insulation resistance Riso> 5 MΩ (500 V DC)
Voltage protection level Up (L-N)≤ 2 kV
Voltage protection level Up (N-PE)≤ 2 kV
Response time tA (L-N)≤ 25 ns
Response time tA (N-PE)≤ 100 ns
Max. backup fuse with branch wiring63 A AC (MCB)
Short-circuit current rating ISCCR10 kA
Follow current quenching capacity Ifi (N-PE)100 A (264 V AC)

Connection, protective circuit

Connection nameConnection protective circuit
Connection methodScrew connection
Connection type INBiconnect screw terminal block
Connection type OUTBiconnect screw terminal block
Connection methodBiconnect terminal block
Tightening torque3.5 Nm
Stripping length15 mm
Conductor cross section flexible min.4 mm²
Conductor cross section flexible max.25 mm²
Conductor cross section solid min.4 mm²
Conductor cross section solid max.25 mm²
Conductor cross section AWG min.12
Conductor cross section AWG max.4
Conductor cross section AWG12 ... 4
Connection nameProtective ground connection
Connection methodScrew connection
Connection type INBiconnect screw terminal block
Connection type OUTBiconnect screw terminal block
Connection methodBiconnect terminal block
Screw threadM5
Tightening torque4.5 Nm
Stripping length16 mm
Conductor cross section flexible min.2.5 mm²
Conductor cross section flexible max.16 mm²
Conductor cross section solid min.2.5 mm²
Conductor cross section solid max.25 mm²
Conductor cross section AWG min.12
Conductor cross section AWG max.2
Conductor cross section AWG12 ... 4

Standards and Regulations

Standards/regulationsIEC 61643-11 2011
EN 61643-11 2012
EN 61008-1
IEC 60947-1
IEC 60947-3

RCD switch

Rated residual operating current IΔn30 mA
Rated making and breaking capacity Im1.5 kA
Rated residual making and breaking capacity IΔm2.5 kA
Rated impulse withstand voltage Uimp6 kV (1.2/50 µs)
Rated conditional short-circuit current Inc10 kA
Tripping time for IΔn≤ 300 ms
Tripping time for 5xIΔn≤ 40 ms
Switching cycles, max.20000
Utilization categoryAC 23 A
Insulation voltage Ui440 V

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2882802-VAL-CP-RCD-3S/40/0.03English313 KbytesPHOENIX CONTACT-2882802-VAL-CP-RCD-3S/40/0.03

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or