CB E1 24DC/4A NO P 2800904 PHOENIX CONTACT Electronic device circuit breaker View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CB E1 24DC/4A NO P 2800904 PHOENIX CONTACT Electronic device circuit breaker

CB E1 24DC/4A NO P

2800904

PHOENIX_CONTACT

Electronic device circuit breaker

More details


Over Current Protection

* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT

Total price: $69.53
Unit price: $69.53

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Key Commercial Data

Orderkey2800904
Packing unit1 pc
Catalog pagePage 322 (C-4-2017)
GTIN4046356690744
Weight per Piece (excluding packing)35.500 g
Custom tariff number85362010
Country of originDE (Germany)

Dimensions

Height45 mm
Width12.3 mm
Depth52 mm
Complete module height90 mm
Complete module width12.3 mm
Complete module depth77.3 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 50 °C (non-condensing)
Ambient temperature (storage/transport)-40 °C ... 70 °C
Humidity test96 h, 95 % RH, 40 °C
Vibration (operation)3g (In accordance with IEC 60068-2-6, Test Fc)
Degree of protectionIP30 (Actuation area)

General

Installation instructionsWhen mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor).
Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC).
Parallel connection of multiple circuit breakers is not permitted.
Flammability rating according to UL 94V0
Mounting typeon base element
Colorgray
Number of positions1
Degree of pollution2
TypeMale

Electrical data

Fuse typeelectronic
Rated surge voltage0.5 kV
Operating voltage24 V DC
18 V DC ... 30 V DC
Nominal current IN4 A
Active current limitationtyp. 1.25 x IN
Closed circuit current I0typ. 8 mA (When switched on)
typ. 17 mA (With alarm output)
Power dissipation0.81 W (Nominal operation)
Temperature derating4 A (at 50 °C)
Tripping methodE (electronic)
Required backup fusenot required, integrated failsafe element
Dielectric strengthmax. 30 V DC (Load circuit)
Voltage drop100 mV (at IN)
Shutdown time load circuit200 ms (see time/current characteristic curve)
Undervoltage shutdown load circuit< 14 V (typ. OFF)
> 17 V (typ. ON)
Max. capacitive load load circuit20000 µF
Auxiliary type of contactfloating signal contact
Minimum auxiliary contact operating voltage10 V DC
Maximum auxiliary contact operating voltage30 V DC
Minimum auxiliary contact operating current10 mA
Maximum auxiliary contact operating current0.5 A

Standards and Regulations

Standards/specificationsUL 2367 UL recognized
UL 508 UL/C-UL listed
EMV EN 61000-6-3 Interference emission
EMV EN 61000-6-2 Noise immunity

Environmental Product Compliance

China RoHSEnvironmentally Friendly Use Period = 50
For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”

Classifications

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.