Changeover switch, with 0 position, Connection method: Screw connection, Number of positions: 1, Function: 1 ‑ 0 ‑ 2, Switching zones: 1, Switching program number: S0210, Rated continuous current: 20 A, Voltage: 690 V
Enclosures connectivity
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Number of connections | 4 |
---|---|
Color | silver/black |
Rotary switch function | 1 ‑ 0 ‑ 2 |
Switching program number | S0210 |
Switching angle | 60 ° |
Rated continuous current | 20 A |
---|---|
Maximum load current | 20 A |
Rated surge voltage | 6 kV |
Rated insulation voltage | 690 V |
Additional text | Valid for networks with grounded neutral point, overvoltage category III, pollution degree 3 |
Rated operating current according to AC-15 (switching of solenoid drives, contactors, valves, pulling electromagnets) | 5 A (220 - 240 V) |
4 A (380 - 440 V) | |
Rated operating current according to AC-21A (switching of ohmic loads including small overloads) | 20 A |
Rated operating current according to AC-22A (switching of mixed ohmic and inductive loads, including small overloads) | 20 A (220 - 500 V) |
20 A (660 - 690 V) | |
Switching power according to AC-3 (squirrel-cage motors: direct starting, switching off motors during operation, star-delta startup (CH16B)) | 3 kW (220 - 240 V; 3-phase, 3-pos.) |
5.5 kW (380 - 440 V; 3-phase, 3-pos.) | |
5.5 kW (500 V; 3-phase, 3-pos.) | |
5.5 kW (660 - 690 V; 3-phase, 3-pos.) | |
0.6 kW (110 - 120 V; 1-phase, 2-pos.) | |
2.2 kW (220 - 240 V; 1-phase, 2-pos.) | |
3 kW (380 - 440 V; 1-phase, 2-pos.) | |
Switching power according to AC-4 (squirrel-cage motors: starting, reversing, plugging, inching) | 0.55 kW (220 - 240 V; 3-phase, 3-pos.) |
1.5 kW (380 - 440 V; 3-phase, 3-pos.) | |
1.5 kW (500 V; 3-phase, 3-pos.) | |
1.5 kW (660 - 690 V; 3-phase, 3-pos.) | |
0.3 kW (110 - 120 V; 1-phase, 2-pos.) | |
0.75 kW (220 - 240 V; 1-phase, 2-pos.) | |
1.5 kW (380 - 440 V; 1-phase, 2-pos.) | |
Switching power according to AC-23A (frequent switching of motors or other highly inductive loads) | 3.7 kW (220 - 240 V; 3-phase, 3-pos.) |
7.5 kW (380 - 440 V; 3-phase, 3-pos.) | |
7.5 kW (500 V; 3-phase, 3-pos.) | |
7.5 kW (660 - 690 V; 3-phase, 3-pos.) | |
0.75 kW (110 - 120 V; 1-phase, 2-pos.) | |
2.5 kW (220 - 240 V; 1-phase, 2-pos.) | |
3.7 kW (380 - 440 V; 1-phase, 2-pos.) | |
Breaking capacity | 150 A (220 - 240 V) |
150 A (380 - 440 V) | |
80 A (660 - 690 V) | |
Ambient temperature (operation) | -35 °C ... 55 °C (Open, at 100% load, with peaks up to 60°C) |
IP immunity to short-circuiting with maximum backup fuse | 25 A |
Additional text | gL/gG characteristics |
Rated short-time current resistance | 140 A |
Additional text | 1 s current |
Width | 48 mm |
---|---|
Length | 62.5 mm |
Height | 48 mm |
Hole diameter | 7 mm |
Height | 29.00 mm |
Installation depth | 33.50 mm |
Ambient temperature (operation) | -35 °C ... 55 °C (Open, at 100% load, with peaks up to 60°C) |
---|
Conductor cross section solid min. | 0.5 mm² |
---|---|
Conductor cross section solid max. | 2.5 mm² |
Conductor cross section AWG min. | 20 |
Conductor cross section AWG max. | 14 |
Conductor cross section flexible min. | 0.75 mm² |
Conductor cross section flexible max. | 2.5 mm² |
Min. AWG conductor cross section, flexible | 18 |
Max. AWG conductor cross section, flexible | 14 |
Conductor cross section / stranded with ferrule without plastic sleeve min. | 2.5 mm² |
Conductor cross section / stranded with ferrule without plastic sleeve max. | 2.5 mm² |
Conductor cross section / stranded with ferrule with plastic sleeve min. | 1.5 mm² |
Conductor cross section / stranded, with ferrule with plastic sleeve max. | 1.5 mm² |
2 conductors with same cross section, solid min. | 0.5 mm² |
2 conductors with same cross section, solid max. | 2.5 mm² |
Two conductors with the same cross section, AWG solid min. | 20 |
Two conductors with the same cross section, AWG solid max. | 14 |
2 conductors with same cross section, stranded min. | 0.75 mm² |
2 conductors with same cross section, stranded max. | 2.5 mm² |
Two conductors with the same cross section, AWG stranded, min. | 18 |
Two conductors with the same cross section, AWG stranded, max. | 14 |
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, minimum | 2.5 mm² |
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, maximum | 2.5 mm² |
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, minimum | 1.5 mm² |
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, maximum | 1.5 mm² |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX TERMINAL BLOCKS EN.pdf | 69 Mbytes | |
PHOENIX CONTACT-3069710-RS20-US-S0210-0103-014H-001 | 124 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.