IL PN BK DI8 DO4 2TX-PAC 2703994 PHOENIX CONTACT PROFINET bus coupler, 8 inputs, 24 V DC, 4 outputs, 24 V DC.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IL PN BK DI8 DO4 2TX-PAC 2703994 PHOENIX CONTACT PROFINET bus coupler, 8 inputs, 24 V DC, 4 outputs, 24 V DC..

IL PN BK DI8 DO4 2TX-PAC

2703994

PHOENIX_CONTACT

Available

Ship on today

PROFINET bus coupler, 8 inputs, 24 V DC, 4 outputs, 24 V DC, 500 mA, complete with I/O connectors

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

I/O systems - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The bus coupler for the PROFINET protocol has 4 digital outputs and 8 digital inputs. This package contains all the necessary Inline plugs for connecting the supply and the I/Os.

The Inline terminals can be labeled using pull-out labeling fields. The fields have insert cards that can be labeled individually to suit the application. Additionally, there is the ZBFM-6... Zack marker strip for labeling the terminal points.

Dimensions

Width80 mm
Height119.8 mm
Depth71.5 mm
Note on dimensionsSpecfications with connectors

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Net weight340 g
Note on weight specificationswith connectors
Mounting typeDIN rail mounting
Diagnostics messagesShort-circuit / overload of the digital outputs Yes
Sensor supply failure Yes
Failure of the actuator supply Yes

Interfaces

Fieldbus systemPROFINET
DesignationPROFINET
Connection methodRJ45 socket, auto negotiation
Transmission speed100 MBit/s (acc. to PROFINET standard)
Transmission physicsEthernet in RJ45 twisted pair
Fieldbus systemLokalbus
DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s / 2 MBit/s (Automatic detection, no combined system)

System limits of the bus coupler

Amount of process datamax. 488 Byte (Max. 244 bytes IN - max. 244 bytes OUT)
Number of supported devicesmax. 63 (per station)
Number of local bus devices that can be connectedmax. 61 (on board I/Os are two devices)
Number of devices with parameter channelmax. 16
Number of supported branch terminals with remote bus branch0

Power supply for module electronics

Connection methodSpring-cage connection
DesignationBus coupler supply UBC; Communications power UL (7.5 V) and the analog supply UANA (24 V) are generated from the bus coupler supply.
Supply voltage24 V DC (via Inline connector)
Supply voltage range19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current consumptiontyp. 138 mA (from UBK)
Power losstyp. 3 W (entire device)
Communications power UL7.5 V DC
Current consumption0.8 A
Power consumptiontyp. 1.7 W

Inline potentials

Communications power UL7.5 V DC ±5 %
Power supply at ULmax. 0.8 A DC
Main circuit supply UM24 V DC
Supply voltage range UM19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at UMmax. 8 A DC (Sum of UM + US; 4 A, maximum, when used in potentially explosive areas.)
Current consumption from UMmax. 8 A DC
Segment supply voltage US24 V DC
Supply voltage range US19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at USmax. 8 A DC (Sum of UM + US; 4 A, maximum, when used in potentially explosive areas.)
Current consumption from USmax. 8 A DC
I/O supply voltage UANA24 V DC
Supply voltage range UANA19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Power supply at UANAmax. 0.5 A DC

Digital inputs

Input nameDigital inputs
Connection methodInline connector
2, 3-wire
Number of inputs8
Typical response timeapprox. 500 µs
Protective circuitProtection against polarity reversal Polarity protection diode
Filter time3 ms
Input characteristic curveIEC 61131-2 type 1
Input voltage24 V DC
Input voltage range "0" signal-30 V DC ... 5 V DC
Input voltage range "1" signal15 V DC ... 30 V DC
Nominal input current at UINtyp. 3 mA
Typical input current per channeltyp. 3 mA
Delay at signal change from 0 to 15 ms
Delay at signal change from 1 to 05 ms

Digital outputs

Output nameDigital outputs
Connection methodInline connector
2, 3-wire
Number of outputs4
Protective circuitShort-circuit and overload protection Free running circuit
Output voltage24 V DC -1 V (At nominal current)
Nominal output voltage24 V DC
Maximum output current per channel500 mA
Maximum output current per module / terminal block2 A
Maximum output current per module2 A
Nominal load, inductive12 VA (1.2 H; 48 Ω)
Nominal load, lamp12 W
Nominal load, ohmic12 W

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2703994-IL PN BK DI8 DO4 2TX-PACEnglish144 KbytesPHOENIX CONTACT-2703994-IL PN BK DI8 DO4 2TX-PAC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or