FLM BK IB M12 DI 8 M12
2736301
PHOENIX_CONTACT
1
The INTERBUS bus coupler opens a local bus for up to 16 devices. Additional functions: easy plug and play installation, 8 digital inputs, channel-specific diagnostics, short-circuit and overload protection, M12 fast connection technology.
I/O
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Fieldline modular bus coupler for INTERBUS with eight digital inputs
Width | 70 mm |
---|---|
Height | 178 mm |
Depth | 50 mm |
Drill hole spacing | 168 mm |
Ambient temperature (operation) | -25 °C ... 60 °C |
---|---|
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (storage/transport) | 95 % |
Air pressure (operation) | 80 kPa ... 106 kPa (up to 2000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP65/IP67 |
Net weight | 280 g |
---|---|
Mounting type | Wall mounting |
Wall mounting, optionally on mounting plate |
Fieldbus system | INTERBUS |
---|---|
Designation | INTERBUS |
Connection method | M12 connector, B-coded |
Designation connection point | Copper cable |
Transmission speed | 500 kBit/s / 2 MBit/s |
Number of positions | 5 |
Designation | Local bus gateway |
---|---|
Connection method | M12 connector, B-coded |
Transmission speed | 500 kbaud/2 Mbaud, can be selected |
Max. number of local bus devices | 16 |
Max. length of local bus | 20 m |
Connection method | M12 connector |
---|---|
Designation | UL |
Supply voltage | 24 V DC |
Supply voltage range | 18 V DC ... 30 V DC (including ripple) |
Voltage supply UL | 24 V DC |
---|---|
Power supply at UL | max. 4 A |
Current consumption from UL | max. 100 mA (At 2 Mbaud) |
typ. 75 mA (At 2 Mbaud) | |
max. 100 mA (At 500 kBaud) | |
typ. 65 mA (At 500 kBaud) | |
Voltage supply US | 24 V DC |
Power supply at US | max. 4 A |
Current consumption from US | typ. 5 mA (plus power supply for sensors) |
max. 600 mA |
Input name | Digital inputs |
---|---|
Connection method | M12 connector |
2, 3, 4-wire | |
Number of inputs | 8 (double-occupancy) |
Protective circuit | Protection against polarity reversal |
Filter time | 3 ms |
Input characteristic curve | IEC 61131-2 type 1 |
Input voltage | 24 V DC |
Input voltage range "0" signal | -30 V DC ... 5 V DC |
Input voltage range "1" signal | 13 V DC ... 30 V DC |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2736301-FLM BK IB M12 DI 8 M12 | 130 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.