Axioline F digital output module, 4 relay outputs, N/O contacts, for nominal voltages up to 230 V AC and 220 V DC, 2-conductor connection technology (including bus base module and connectors), corresponds to standard IEC 61850-3

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Ethernet networks. Switches, routers, and antennas - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Product description

The module is intended for use within an Axioline F station.

It has four floating relay N/O contacts which are independent of one another.

Low-voltage and extra-low-voltage modules can be used side by side within an Axioline F station.

Dimensions

Width53.6 mm
Height126.1 mm
Depth54 mm
Note on dimensionsThe depth is valid when a TH 35-7.5 DIN rail is used (according to EN 60715).

Ambient conditions

Ambient temperature (operation)-25 °C ... 60 °C (Max. 6 A/channel for wall mounting on horizontal DIN rail; max. 4 A/channel for any mounting position)
-25 °C ... 50 °C (Max. 8 A/channel for wall mounting on horizontal DIN rail; max. 6 A/channel for any mounting position)
-25 °C ... 40 °C (Max. 8 A/channel for any mounting position)
Ambient temperature (storage/transport)-40 °C ... 85 °C
Permissible humidity (operation)5 % ... 95 % (non-condensing)
Permissible humidity (storage/transport)5 % ... 95 % (non-condensing)
Air pressure (operation)80 kPa ... 106 kPa (up to 2000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

Connection data

DesignationAxioline F connector
Connection methodPush-in connection
Note on connection methodPlease observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.1.5 mm²
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.1.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.16
Stripping length8 mm

General

Net weight222 g
Note on weight specificationswith connectors and bus base module
Mounting typeDIN rail
Pollution degree2

Interfaces

DesignationAxioline F local bus
Connection methodBus base module
Transmission speed100 MBit/s

Axioline potentials

Communications power UBus5 V DC (via bus base module)
Current consumption from UBusmax. 280 mA (all relays pick up)

Digital outputs

Output nameRelay output
Connection methodPush-in connection
2-wire
Number of outputs4
Nominal output voltage220 V DC
Maximum output current per channel8 A
Maximum output current per module32 A (external fuse)