IB IL SGI 2/P-PAC 2884907 PHOENIX CONTACT Inline analog strain gauge input terminal, complete with accessori.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

IB IL SGI 2/P-PAC 2884907 PHOENIX CONTACT Inline analog strain gauge input terminal, complete with accessori..

IB IL SGI 2/P-PAC

2884907

PHOENIX_CONTACT

Available

Ship on today

Inline analog strain gauge input terminal, complete with accessories (plug and labeling field), two precise inputs, 4, 6-conductor connection method

More details


AUTOMATION Industrial Automation - PHOENIX CONTACT

Control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Note

Utilization restrictionEMC: class A product, see manufacturer's declaration in the download area

Dimensions

Width48.8 mm
Height136 mm
Depth71.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 55 °C
Ambient temperature (storage/transport)-25 °C ... 85 °C
Permissible humidity (operation)10 % ... 95 % (according to DIN EN 61131-2)
Permissible humidity (storage/transport)10 % ... 95 % (according to DIN EN 61131-2)
Air pressure (operation)70 kPa ... 106 kPa (up to 3000 m above sea level)
Air pressure (storage/transport)70 kPa ... 106 kPa (up to 3000 m above sea level)
Degree of protectionIP20

General

Mounting typeDIN rail
Net weight220 g
Operating modeProcess data operation with 3 words, PCP with 1 word
Diagnostics messagesFailure of the power supply at UANA Error message in the process data
Failure of or insufficient communications power UL I/O error message sent to the bus coupler
Peripheral fault Error message in the process data

Interfaces

DesignationInline local bus
Connection methodInline data jumper
Transmission speed500 kBit/s
Transmission physicsCopper

Serial interface

DesignationV.24 (RS-485) serial interface
NetworkYes
AddressingAddress 1 = Measured gross/net value
Address 2 = Measured tare value
Termination resistor120 Ω
Transmission protocolSTX/ETX

Inline potentials

Communications power UL7.5 V DC
Current consumption from ULmax. 100 mA
typ. 85 mA
I/O supply voltage UANA24 V DC
Current consumption from UANAmax. 100 mA
25 mA (in case of typical load of 350 Ohm per channel)
7 mA (for no-load operation without strain gauge or display)
80 mA (For a maximum load of 55 Ω and display)
Power consumptiontyp. 1.2 W (Device in nominal operation)
max. 3.2 W (Device with maximum load)

Contacts

DescriptionFloating N/O contact
Quantity2 (Ka1-Kb1, Ka2-Kb2)
Contact resistance< 1 Ω (typical)
Typical response timetyp. 100 ms

Analog inputs

Description of the inputInput channels for strain gauge
Number of inputs2
Connection method6 or 4-wire, twisted pair shielded cable
Bridge difference UdMeasuring range specified by selecting the characteristic
Bridge voltage U05 V
Characteristics±1 mV/V, ±2 mV/V, ±3 mV/V, ±3.33 mV/V, ±4 mV/V, ±5 mV/V
Measured value representation15 bits + sign bit (process data); 15 bits + sign bit and measured display value in the ASCII character set (PCP)
Process data updatetyp. 100 ms (12.5 ms, depends on the configuration)

Analog outputs

Type of protectionShort-circuit protection of the voltage outputs
Protective circuit/componentYes, at least 1 minute through temperature monitoring
Output descriptionVoltage output
Number of outputs2
Impedance> 55 Ω (per channel)
Output voltagetyp. 5 V
Output currentmax. 90 mA (per channel)
Maximum output currentmax. 90 mA (per channel)

Standards and Regulations

Test sectionLogic/analog I/O (digital isolator) 500 V AC 50 Hz 1 min.
RS-485/analog I/O (isolating distance) 500 V AC 50 Hz 1 min.
N/O contact Ka1 - Kb1 / analog I/O (isolating distance) 500 V AC 50 Hz 1 min.
N/O contact Ka2 - Kb2 / analog I/O (isolating distance) 500 V AC 50 Hz 1 min.
Functional earth ground/analog I/O (isolating distance) 500 V AC 50 Hz 1 min.
Logic/RS-485 (digital isolator) 500 V AC 50 Hz 1 min.
N/O contact Ka1 - Kb1 / RS-485 (isolating distance) 500 V AC 50 Hz 1 min.
N/O contact Ka2 - Kb2 / RS-485 (isolating distance) 500 V AC 50 Hz 1 min.
Functional earth ground/RS-485 (isolating distance) 500 V AC 50 Hz 1 min.
Logic / N/O contact Ka1 - Kb1 (optocoupler) 500 V AC 50 Hz 1 min.
N/O contact Ka2 - Kb2/N/O contact Ka1 - Kb1 (isolating distance) 500 V AC 50 Hz 1 min.
Functional earth ground / N/O contact Ka1 - Kb1 (isolating distance) 500 V AC 50 Hz 1 min.
Logic / N/O contact Ka2 - Kb2 (optocoupler) 500 V AC 50 Hz 1 min.
Functional earth ground / N/O contact Ka2 - Kb2 (isolating distance) 500 V AC 50 Hz 1 min.
Logic/functional earth ground (isolating distance) 500 V AC 50 Hz 1 min.
Protection classIII, IEC 61140, EN 61140, VDE 0140-1

[email protected]

[email protected] 4.027250303
[email protected] 4.127250303
[email protected] 5.027250303
[email protected] 5.127242601
[email protected] 6.027242601
[email protected] 7.027242601
[email protected] 8.027242601

ETIM

ETIM 2.0EC001431
ETIM 3.0EC001596
ETIM 4.0EC001596
ETIM 5.0EC001596

UNSPSC

UNSPSC 6.0143172015
UNSPSC 7.090143201404
UNSPSC 1143172015
UNSPSC 12.0143201404
UNSPSC 13.243201404

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2884907-IB IL SGI 2/P-PACEnglish148 KbytesPHOENIX CONTACT-2884907-IB IL SGI 2/P-PAC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or