Inline analog strain gauge input terminal, without accessories, evaluating electronics with EC type approval
I/O
* Brand new product in its original packaging covered by the warranties and certifications provided by PHOENIX_CONTACT
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Width | 48.8 mm |
---|---|
Height | 120 mm |
Depth | 71.5 mm |
Note on dimensions | Dimensions with covering hood |
Ambient temperature (operation) | -25 °C ... 55 °C (Type approval according to DIN EN 45501 and OIML R76: -10°C ... 40°C) |
---|---|
Ambient temperature (storage/transport) | -25 °C ... 85 °C |
Permissible humidity (operation) | 10 % ... 95 % (according to DIN EN 61131-2) |
Permissible humidity (storage/transport) | 10 % ... 95 % (according to DIN EN 61131-2) |
Air pressure (operation) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Air pressure (storage/transport) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
Degree of protection | IP20 |
Net weight | 160 g |
---|---|
Mounting type | DIN rail |
Operating mode | Process data operation with 2 words, PCP with 2 words |
Diagnostics messages | Failure of the power supply at UANA Error message in the process data |
Failure of or insufficient communications power UL I/O error message sent to the bus coupler | |
Peripheral fault Error message in the process data | |
User error Error message in the process data |
Fieldbus system | Lokalbus |
---|---|
Designation | Inline local bus |
Connection method | Inline data jumper |
Transmission speed | 500 kBit/s |
Designation | RS-485 |
---|---|
Network | Yes |
Addressing | Address 0 = Broadcast, alternating display of measured gross/net value and measured tare value |
Address 1 = Measured gross/net value | |
Address 2 = Measured tare value | |
Address 3 ... 9 = reserved | |
Termination resistor | 120 Ω |
Transmission protocol | STX/ETX |
Communications power UL | 7.5 V DC |
---|---|
Current consumption from UL | typ. 80 mA |
max. 100 mA | |
I/O supply voltage UANA | 24 V DC |
Current consumption from UANA | max. 50 mA |
12 mA (For a typical load of 350 Ω and display) | |
43 mA (For a maximum load of 55 Ω and display) | |
Power consumption | typ. 1 W (Device in nominal operation) |
max. 2 W (Device with maximum load) |
Description | Lock of parameters |
---|---|
Quantity | 1 (PSa - PSb) |
Logic | PSa - PSb connected = Parameter locked |
Typical response time | < 100 ms |
Description of the input | Input channel for strain gauge |
---|---|
Number of inputs | 1 |
Connection method | 6-wire, twisted pair shielded cable |
Bridge difference Ud | Measuring range specified by selecting the characteristic |
Bridge voltage U0 | 5 V |
Characteristics | ±1 mV/V, ±2 mV/V, ±3 mV/V, ±3.33 mV/V, ±4 mV/V, ±5 mV/V |
Measured value representation | Process data: status bits and measured value including decimal places of the gross/net display |
Process data update | typ. 100 ms |
Type of protection | Short-circuit protection of the voltage outputs |
---|---|
Protective circuit/component | Yes, at least 1 minute through temperature monitoring |
Output description | Voltage output |
Number of outputs | 1 |
Impedance | > 55 Ω |
Output voltage | typ. 5 V ±2 % |
max. 5 V ±5 % | |
Output current | max. 90 mA |
Maximum output current | max. 90 mA |
Title: | Size: | Type: |
---|---|---|
PDF CATALOG PHOENIX AUTOMATION EN.pdf | 35 Mbytes | |
PHOENIX CONTACT-2700064-IB IL SGI 1/CAL | 122 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.