MCR 3-way isolating amplifier, with configurable input/output, for electrical isolation and conversion of analog signals in the mV range, single-pos. as well as 2-pos. with spring-cage connection, pre-configured

More details


Overvoltage Protection Over Voltage

TRABTECH Power and Signal Quality - PHOENIX CONTACT

Surge protection for measurement and control technology - PHOENIX CONTACT

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$144.62
2+$140.70
3+$138.76
4+$137.52
6+$136.12
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width6.2 mm
Height93.1 mm
Depth102.5 mm

Ambient conditions

Ambient temperature (operation)-20 °C ... 65 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

Number of inputs1
Configurable/programmableYes, unconfigured
Voltage input signal-50 mV ... 50 mV
-60 mV ... 60 mV
-75 mV ... 75 mV
-80 mV ... 80 mV
-100 mV ... 100 mV
-120 mV ... 120 mV
-150 mV ... 150 mV
-200 mV ... 200 mV
-240 mV ... 240 mV
-300 mV ... 300 mV
-500 mV ... 500 mV
-600 mV ... 600 mV
-750 mV ... 750 mV
-800 mV ... 800 mV
-1 V ... 1 V
-1.2 V ... 1.2 V
-1.5 V ... 1.5 V
-2 V ... 2 V
-2.4 V ... 2.4 V
-3 V ... 3 V
0 mV ... 50 mV
0 mV ... 60 mV
0 mV ... 75 mV
0 mV ... 80 mV
0 mV ... 100 mV
0 mV ... 120 mV
0 mV ... 150 mV
0 mV ... 200 mV
0 mV ... 240 mV
0 mV ... 300 mV
0 mV ... 500 mV
0 mV ... 600 mV
0 mV ... 750 mV
0 mV ... 800 mV
0 V ... 1 V
0 V ... 1.2 V
0 V ... 1.5 V
0 V ... 2 V
0 V ... 2.4 V
0 V ... 3 V
Max. input voltageapprox. 3 V DC
Input resistance of voltage inputapprox. 10 kΩ

Output data

Number of outputs1
Configurable/programmableYes, unconfigured
Voltage output signal0 V ... 10 V
2 V ... 10 V
0 V ... 5 V
1 V ... 5 V
-10 V ... 10 V (The bi-polar output can be used only for bi-polar input signals.)
-5 V ... 5 V (The bi-polar output can be used only for bi-polar input signals.)
Current output signal0 mA ... 20 mA
4 mA ... 20 mA
Load/output load voltage output≥ 10 kΩ
Load/output load current output< 500 Ω (at 20 mA)

Power supply

Nominal supply voltage24 V DC
Supply voltage range19.2 V DC ... 30 V DC
Max. current consumption< 25 mA
Power consumption< 450 mW (Current output)

Connection data

Connection methodSpring-cage connection
Conductor cross section solid min.0.2 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.24
Conductor cross section AWG max.12
Conductor cross section flexible min.0.2 mm²
Conductor cross section flexible max.2.5 mm²
Stripping length8 mm
Connection method2-wire

General

No. of channels1
Maximum transmission error≤ 0.2 %
< 0.4 % (Without adjustment)
Maximum temperature coefficient< 0.01 %/K
Temperature coefficient, typical< 0.002 %/K
Limit frequency (3 dB)100 Hz / 30 Hz switchable
Step response (10-90%)3.5 ms (At 100 Hz)
Electrical isolationBasic insulation according to EN 61010
Overvoltage categoryII
Pollution degree2
Rated insulation voltage50 V AC/DC
Test voltage, input/output/supply1.5 kV (50 Hz, 1 min.)
Electromagnetic compatibilityConformance with EMC Directive 2004/108/EC
Noise emissionEN 61000-6-4
Noise immunityEN 61000-6-2 When being exposed to interference, there may be minimal deviations.
Colorgreen
Housing materialPBT
Mounting positionany
Assembly instructionsThe T connector can be used to bridge the supply voltage. It can be snapped onto a 35 mm DIN rail according to EN 60715.
ConformanceCE-compliant
ATEXEx II 3 G Ex nA IIC T4 Gc X
UL, USA / CanadaUL 508 Recognized
Class I, Div. 2, Groups A, B, C, D T5 applied for
GLGL EMC 2 D

EMC data

DesignationElectromagnetic RF field
Standards/regulationsEN 61000-4-3
Typical deviation from the measuring range final value6 %
DesignationFast transients (burst)
Standards/regulationsEN 61000-4-4
Typical deviation from the measuring range final value6 %
DesignationConducted interferences
Standards/regulationsEN 61000-4-6
Typical deviation from the measuring range final value6 %

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2810793-MINI MCR-SL-SHUNT-UI-SP-NCEnglish156 KbytesPHOENIX CONTACT-2810793-MINI MCR-SL-SHUNT-UI-SP-NC

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or