Amp meter changeover switch, Connection method: Screw connection, Number of positions: 1, Function: 0 ‑ 1 ‑ 2 ‑ 3, Switching zones: 3, Switching program number: S0048, Rated continuous current: 20 A, Voltage: 690 V

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$39.17
6+$35.87
12+$35.00
17+$34.62
23+$34.35
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



General

Number of connections12
Colorsilver/black
Rotary switch function0 ‑ 1 ‑ 2 ‑ 3
Switching program numberS0048
Switching angle90 °

General

Rated continuous current20 A
Maximum load current20 A
Rated surge voltage6 kV
Rated insulation voltage690 V
Additional textValid for networks with grounded neutral point, overvoltage category III, pollution degree 3
Rated operating current according to AC-15 (switching of solenoid drives, contactors, valves, pulling electromagnets)5 A (220 - 240 V)
4 A (380 - 440 V)
Rated operating current according to AC-21A (switching of ohmic loads including small overloads)20 A
Rated operating current according to AC-22A (switching of mixed ohmic and inductive loads, including small overloads)20 A (220 - 500 V)
20 A (660 - 690 V)
Switching power according to AC-3 (squirrel-cage motors: direct starting, switching off motors during operation, star-delta startup (CH16B))3 kW (220 - 240 V; 3-phase, 3-pos.)
5.5 kW (380 - 440 V; 3-phase, 3-pos.)
5.5 kW (500 V; 3-phase, 3-pos.)
5.5 kW (660 - 690 V; 3-phase, 3-pos.)
0.6 kW (110 - 120 V; 1-phase, 2-pos.)
2.2 kW (220 - 240 V; 1-phase, 2-pos.)
3 kW (380 - 440 V; 1-phase, 2-pos.)
Switching power according to AC-4 (squirrel-cage motors: starting, reversing, plugging, inching)0.55 kW (220 - 240 V; 3-phase, 3-pos.)
1.5 kW (380 - 440 V; 3-phase, 3-pos.)
1.5 kW (500 V; 3-phase, 3-pos.)
1.5 kW (660 - 690 V; 3-phase, 3-pos.)
0.3 kW (110 - 120 V; 1-phase, 2-pos.)
0.75 kW (220 - 240 V; 1-phase, 2-pos.)
1.5 kW (380 - 440 V; 1-phase, 2-pos.)
Switching power according to AC-23A (frequent switching of motors or other highly inductive loads)3.7 kW (220 - 240 V; 3-phase, 3-pos.)
7.5 kW (380 - 440 V; 3-phase, 3-pos.)
7.5 kW (500 V; 3-phase, 3-pos.)
7.5 kW (660 - 690 V; 3-phase, 3-pos.)
0.75 kW (110 - 120 V; 1-phase, 2-pos.)
2.5 kW (220 - 240 V; 1-phase, 2-pos.)
3.7 kW (380 - 440 V; 1-phase, 2-pos.)
Breaking capacity150 A (220 - 240 V)
150 A (380 - 440 V)
80 A (660 - 690 V)
Ambient temperature (operation)-35 °C ... 55 °C (Open, at 100% load, with peaks up to 60°C)
IP immunity to short-circuiting with maximum backup fuse25 A
Additional textgL/gG characteristics
Rated short-time current resistance140 A
Additional text1 s current

Dimensions

Width48 mm
Length81.5 mm
Height48 mm
Hole diameter7 mm
Height29.00 mm
Installation depth52.50 mm

Ambient conditions

Ambient temperature (operation)-35 °C ... 55 °C (Open, at 100% load, with peaks up to 60°C)

Connection data

Conductor cross section solid min.0.5 mm²
Conductor cross section solid max.2.5 mm²
Conductor cross section AWG min.20
Conductor cross section AWG max.14
Conductor cross section flexible min.0.75 mm²
Conductor cross section flexible max.2.5 mm²
Min. AWG conductor cross section, flexible18
Max. AWG conductor cross section, flexible14
Conductor cross section / stranded with ferrule without plastic sleeve min.2.5 mm²
Conductor cross section / stranded with ferrule without plastic sleeve max.2.5 mm²
Conductor cross section / stranded with ferrule with plastic sleeve min.1.5 mm²
Conductor cross section / stranded, with ferrule with plastic sleeve max.1.5 mm²
2 conductors with same cross section, solid min.0.5 mm²
2 conductors with same cross section, solid max.2.5 mm²
Two conductors with the same cross section, AWG solid min.20
Two conductors with the same cross section, AWG solid max.14
2 conductors with same cross section, stranded min.0.75 mm²
2 conductors with same cross section, stranded max.2.5 mm²
Two conductors with the same cross section, AWG stranded, min.18
Two conductors with the same cross section, AWG stranded, max.14
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, minimum2.5 mm²
2 conductors with the same cross section/stranded, with ferrule and without plastic sleeve, maximum2.5 mm²
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, minimum1.5 mm²
2 conductors with the same cross section/stranded, with ferrule and plastic sleeve, maximum1.5 mm²

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-3069704-RS20-US-S0048-0304-014H-001English128 KbytesPHOENIX CONTACT-3069704-RS20-US-S0048-0304-014H-001

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or