PLC-OPT- 36DC/110DC/3RW 2900392 PHOENIX CONTACT PLC-INTERFACE for railway applications, consisting of basic .. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-OPT- 36DC/110DC/3RW 2900392 PHOENIX CONTACT PLC-INTERFACE for railway applications, consisting of basic ..

PLC-OPT- 36DC/110DC/3RW

2900392

PHOENIX_CONTACT

10

Available

Ship on today

PLC-INTERFACE for railway applications, consisting of basic terminal block with push-in connection and integrated miniature solid-state relay, range: 0.7 x UN to 1.25 x UN, temperature range: -25°C to +70°C, 1 N/O contact, input: 36 V DC, output: 12 - 140 V DC/3 A

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
10+$47.26
20+$46.57
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dimensions

Width6.2 mm
Height80 mm
Depth86 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C
Ambient temperature (storage/transport)-40 °C ... 85 °C
Degree of protectionIP20

Input data

Nominal input voltage UN36 V DC
Input voltage range in reference to UN0.7 ... 1.25 (t < 1 s = 0.6 ... 1.4 x UN)
Switching threshold "0" signal in reference to UN< 0.4
Switching threshold "1" signal in reference to UN> 0.6
Typical input current at UN12 mA
Typical response time400 µs
Typical turn-off time100 µs
Operating voltage displayYellow LED
Type of protectionProtection against polarity reversal
Surge protection
Protective circuit/componentSeries polarity protection diode
Surge voltage protection> 150 V
Transmission frequency50 Hz

Output data

Output nominal voltage110 V DC
Output voltage range12 V DC ... 140 V DC (t < 1 s = 1.40 x UN)
Limiting continuous current3 A (see derating curve)
Surge voltage protection> 150 V
Voltage drop at max. limiting continuous current< 150 mV
Output circuit2-wire, floating
Type of protectionProtection against polarity reversal
Surge protection
Protective circuit/componentParallel polarity protection diode

Connection data, input side

Connection nameInput side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

General

Test voltage input/output2.5 kVrms
Mounting positionany
Assembly instructionsIn rows with zero spacing
Operating mode100% operating factor
Flammability rating according to UL 94V0
DesignationAir clearances and creepage distances between the power circuits
Standards/regulationsIEC 60664
EN 50178
IEC 62103
Rated surge voltage/insulation4 kV / basic insulation
Rated insulation voltage160 V DC
Pollution degree2
Overvoltage categoryIII

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2900392-PLC-OPT- 36DC/110DC/3RWEnglish127 KbytesPHOENIX CONTACT-2900392-PLC-OPT- 36DC/110DC/3RW

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or