PLC-INTERFACE for railway applications, consisting of basic ter - PHOENIX CONTACT - PLC-RPT- 24UC/21/RW - 2900318 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PLC-INTERFACE for railway applications, consisting of basic ter - PHOENIX CONTACT - PLC-RPT- 24UC/21/RW - 2900318






Ship on today

PLC-INTERFACE for railway applications, consisting of basic terminal block with push-in connection and plug-in miniature relay with power contact, range: 0.7 x UN to 1.25 x UN, temperature class TX: -40°C to +70°C, 1 PDT, input voltage 24 V DC

More details



* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

Price: $32.18
*This price is per unit and is the net value (not including taxes if applicable).
Up to 35% discount for registered clients.

Request a quote
How it Works

How does the quotation request work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with our price proposals
4 You can directly process the order for the quotation

There are several options for payment
- Credit card
- Wire Transfer
- PayPal

More info


Width6.2 mm
Height80 mm
Depth94 mm

Ambient conditions

Ambient temperature (operation)-40 °C ... 70 °C (Temperature class TX)
Ambient temperature (storage/transport)-40 °C ... 85 °C

Coil side

Nominal input voltage UN24 V DC
Input voltage range in reference to UN0.7 ... 1.25
Typical input current at UN9 mA
Typical response time4 ms
Typical release time4 ms
Coil voltage12 V DC
Protective circuitBridge rectifier Bridge rectifier
Free-wheeling diode Damping diode
Surge protection
RCZ filter
Wide-range electronics
Operating voltage displayYellow LED
Power dissipation for nominal condition0.22 W

Contact side

Contact type1 PDT
Contact materialAgSnO
Maximum switching voltage250 V AC/DC (Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules.)
Minimum switching voltage5 V (at 100 mA)
Min. switching current10 mA (at 12 V)
Maximum inrush currenton request
Limiting continuous current6 A
Interrupting rating (ohmic load) max.140 W (at 24 V DC)
20 W (at 48 V DC)
18 W (at 60 V DC)
23 W (at 110 V DC)
40 W (at 220 V DC)
1500 VA (for 250 V AC)
Switching capacity in acc. with DIN VDE 0660/IEC 609471 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.1 A (at 220 V, DC13)
3 A (at 24 V, AC15)
3 A (at 120 V, AC15)
3 A (at 230 V, AC15)


Test voltage relay winding/relay contact4 kVrms (50 Hz, 1 min.)
Operating mode100% operating factor
Degree of protectionRT III (Relay)
IP20 (Relay socket)
Mechanical service lifeApprox. 2 x 107 cycles
Flammability rating according to UL 94V0
Standards/regulationsEN 50155 (VDE 0115 part 200)
EN 50178
IEC 62103
EN 61373
EN 50121
Rated surge voltage/insulation6 kV
Rated insulation voltage250 V AC
Pollution degree2
Overvoltage categoryIII
Mounting positionany
Assembly instructionsIn rows with zero spacing

Connection data input side

Connection nameCoil side
Connection methodPush-in connection
Stripping length8 mm
Conductor cross section solid0.14 mm² ... 2.5 mm²
Conductor cross section flexible0.14 mm² ... 2.5 mm²
Conductor cross section AWG26 ... 14

PDF of PLC-INTERFACE for railway applications, consisting of basic ter - PHOENIX CONTACT - PLC-RPT- 24UC/21/RW - 2900318

PHOENIX CONTACT-2900318-PLC-RPT- 24UC/21/RWEnglish88 KbytesPHOENIX CONTACT-2900318-PLC-RPT- 24UC/21/RW

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait

* Required fields