Hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 230 V AC input, 9 A output current, and adjustable overload shutdown.

More details


Programmable Logic Controllers Plcs

* Brand new produt in its original packing covered by the warranties and certifications provided by PHOENIX_CONTACT

QuantityPrice
1+$129.80
2+$126.17
4+$123.22
5+$122.39
7+$121.51
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Input data

Input nameDevice supply
Rated control circuit supply voltage US230 V AC (50/60 Hz)
Rated control supply current IS4 mA
Protective circuitSurge protection
Operating voltage displayGreen LED
Status displayYellow LED
IndicationRed LED
Input nameControl input right/left
Rated actuating voltage UC230 V AC
Rated actuating current IC7 mA
Switching threshold44 V AC (“0” signal)
85 V AC (“1” signal)
Typical turn-off time< 70 ms

Output data load output

Rated operating voltage Ue500 V AC
Operating voltage range42 V AC ... 550 V AC
Load current range1.5 A ... 9 A (see to derating)
Trigger characteristic in acc. with IEC 60947Class 10A
Rated operating current at AC-519 A
Rated operating current at AC-53a6.5 A
Leakage current0 mA
Protective circuitSurge protection

Output data reply output

NoteConfirmation: floating change-over contact, signal contact
Contact type1 PDT

Connection data, control circuit

Connection nameControl circuits
Connection methodScrew connection
Stripping length8 mm
Screw threadM3
Conductor cross section solid0.2 mm² ... 2.5 mm²
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Conductor cross section AWG24 ... 14
Torque0.5 Nm ... 0.6 Nm

General

Switching frequency≤ 2 Hz (Load-dependent)
Mounting positionvertical (horizontal DIN rail, motor output below)
Assembly instructionsalignable, for spacing see derating
Operating mode100% operating factor
DesignationStandards/regulations
Standards/regulationsIEC 60947-1
EN 60947-4-2
IEC 61508
ISO 13849

Dimensions

Width22.5 mm
Height99 mm
Depth114.5 mm

Ambient conditions

Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Degree of protectionIP20

Datasheet - PDF

Title:Language:Size:Type:
PHOENIX CONTACT-2900578-ELR H5-I-SC-230AC/500AC-9English147 KbytesPHOENIX CONTACT-2900578-ELR H5-I-SC-230AC/500AC-9

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or