SQ4-A21-P PANASONIC Safety Liquid Leak Sensor, standard liquids, Category 1, Plc, SIL1, PNP output, cable 2m View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

SQ4-A21-P PANASONIC Safety Liquid Leak Sensor, standard liquids, Category 1, Plc, SIL1, PNP output, cable 2m

SQ4-A21-P

PANASONIC

Safety Liquid Leak Sensor, standard liquids, Category 1, Plc, SIL1, PNP output, cable 2m

Liquid Detection Safety Sensor, Category 1, Ple, SIL1, PNP, 2m cable

SQ4-A21-P_Safety Liquid Leak Sensor [Control Category 4 PLe SIL3]_Safety Liquid Leak Sensor [Control Category 4 PLe SIL3] SQ4_Sensor [For standard liquid]

More details


Special Photoelectric Sensors - PANASONIC > SQ4 Leak detection photoelectric sensors. Pie SIL3 - PANASONIC

* Brand new product in its original packaging covered by the warranties and certifications provided by PANASONIC

* This article is restricted. Please ask us for a quotation and we will check if there are units available or we will offer you an alternative product.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Product NumberSQ4-A21-P
Part NumberSQ4-A21-P
ProductSafety Liquid Leak Sensor [Control Category 4 PLe SIL3]
DetailsSensor [For standard liquid]
Product nameSafety Liquid Leak Sensor [Control Category 4 PLe SIL3] SQ4

ItemSpecifications
Product NumberSQ4-A21-P
Part NumberSQ4-A21-P
CE marking directive complianceMachinery Directive, EMC Directive, RoHS Directive
Sensing objectWater (Standard liquid)
(Note) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition.
Sensing rangeWater (Standard liquid)
(Note) The agents mentioned above are examples. It may not be detected depending on viscosity the agent. Before using this device, check the detecting liquid and installation condition.
Power voltage12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less
Current consumption30 mA or less
Utilization categoryDC-12, DC-13
Detection output(Leakage detection)PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: Same as the supply voltage (between detection output and +V)
- Residual voltage: 2.5 V or less (at 50 mA source current)
Detection output(Leakage detection):Response time10 ms or less
Detection output(Leakage detection):Output operationON when normal condition or initial detection, OFF when detection leakage or wrong installation
Detection auxiliary output(Initial detection)PNP open-collector transistor
- Maximum source current: 50 mA
- Applied voltage: Same as the supply voltage (between detection auxiliary output and +V)
- Residual voltage: 2.5 V or less (at 50 mA source current)
Detection auxiliary output(Initial detection):Response time50 ms or less
Detection auxiliary output(Initial detection):Output operationON when normal condition, OFF when initial detection or accidental leakage
ProtectionIP65 / IP67 (IEC)
Ambient temperature-10 to +55 ℃ +14 to +131 ℉ (No dew condensation or icing allowed) (Note) Storage: -10 to +55 ℃ +14 to +131 ℉
(Note) Liquid being detected should be also kept within the rated ambient temperature range.
Ambient humidity35 to 85 % RH, Storage: 35 to 85 % RH
Emitting elementInfrared LED (modulated)
MaterialEnclosure: Polypropylene
Cable0.18 mm2 4-core PVC cabtyre cable, 2 m 6.562 ft long
WeightNet weight: 45 g approx
Gross weight: 110 g approx

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.