Product successfully added to your shopping cart
SF2C-H32-N
PANASONIC
1
Ultra-slim Safety Light Curtain Typ2 (PLc SIL1), Hand Protection, protective height 640 mm, NPN, cable-type 3m, IP67
Safety - PANASONIC > SF2B thru-beam safety sensors type 2 PLd SIL2, P - PANASONIC
* Brand new product in its original packaging covered by the warranties and certifications provided by PANASONIC
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Product Number | SF2C-H32-N |
Part Number | SF2C-H32-N |
Product | Ultra-slim Light Curtain [Type 2 PLc SIL1] |
Details | Hand protection type Min. sensing object ø25 mmø0.984 in(20 mm0.787 inbeam pitch) |
Product name | Ultra-slim Light Curtain [Type2 PLc SIL1] SF2C |
Item | Specifications |
---|---|
Product Number | SF2C-H32-N |
Part Number | SF2C-H32-N |
CE marking directive compliance | Machinery Directive, EMC Directive, RoHS Directive |
No. of beam channels | 32 |
Protective height | 640 mm25.197 in |
Current consumption:Large multipurpose indicator lights off | Emitter: 35 mA or less Receiver: 35 mA or less |
Current consumption:Large multipurpose indicator lights up | Emitter: 50 mA or less Receiver: 45 mA or less |
PFHD | 4.12 × 10-9 (Note) Probability of dangerous failure per hour. |
MTTFD | 100 years or more (Note) Mean time to dangerous failure. |
Net weight (Total of emitter and receiver) | 640 g approx. |
Applicable standards:International standard | IEC 61496-1 / 2 (Type 2), ISO 13849-1 (Category 2, PLc), IEC 61508-1 to 7 (SIL 1) |
Applicable standards:Japan | JIS B 9704-1 / 2 (Type 2), JIS B 9705-1 (Category 2), JIS C 0508 (SIL 1) |
Applicable standards:Europe (EU) | EN 61496-1 (Type 2), EN ISO 13849-1 (Category 2, PLc), EN 61508-1 to 7 (SIL 1), EN 55011, EN 50178, EN 61000-6-2 (Note) Regarding EU Machinery Directive, a Notified Body, TUV SUD, has certified with the type examination certificate. |
Applicable standards:North America | ANSI / UL 61496-1 / 2 (Type 2), ANSI / UL 508, CAN / CSA 61496-1 / 2 (Type 2), CAN / CSA C22.2 No.14, ANSI / RIA 15.06 (Note) With regard to the standards in US / Canada, TUV SUD, has certified for cTUVus Mark. |
Operating range | 0.1 to 3 m0.328 to 9.843 ft |
Beam pitch | 20 mm0.787 in |
Min. sensing object | ø25 mmø0.984 inopaque object |
Effective aperture angle | plus or minus 5℃ or less [for an operating range exceeding 3 m 9.843 ft (conforming to IEC 61496-2 / ANSI/UL 61496-2) ] |
Power voltage | 24 V DC plus or minus 20 % Ripple P-P 10 % or less |
Control output(OSSD) | - Maximum sink current: 200mA - Applied voltage: same as supply voltage (between the control output and -0V) - Residual voltage: 2.5V or less (sink current 200mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less |
Control output(OSSD):Operation mode | ON when all beam channels are received, OFF when one or more beam channels are interrupted (OFF also in case of any malfunction in the safety light curtain or the synchronization signal) |
Control output(OSSD):Protection circuit | Incorporated |
Response time | OFF response: 20 ms or less ON response: 80 to 100 ms |
Lockout output(SSD) | - Maximum sink current: 60mA - Applied voltage: same as supply voltage (between the lockout output and -0V) - Residual voltage: 2.5V or less (sink current 60mA, when using 10m length cable) - Leakage current: 200micro A or less (power supply OFF condition) - Maximum load capacity: 2.2micro F (No load to maximum output current) - Load wiring resistance: 3Ω or less |
Lockout output(SSD):Operation mode | ON during normal operation, OFF during lockout (Note) If the emitter enters a lockout state, and light from the emitter enters the receiver, lockout information will be transmitted and lockout output (SSD) will turn OFF. |
Lockout output(SSD):Protection circuit | Incorporated |
Interference prevention function | Incorporated |
Test input function | Incorporated |
Large multi-purpose indicator function | Incorporated |
Pollution degree | 3 |
Operating altitude | 2, 000 m6561.680 ftor less (Note) Do not use or store in an environment pressurized to atmospheric pressure or higher at an altitude of 0 m. |
Environmental resistance:Degree of protection | IP65, IP67 (IEC) |
Ambient temperature | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: - 25 to +60 ℃- 13 to +140 ℉ |
Ambient humidity | 30 to 85 % RH, Storage: 30 to 85 % RH |
Ambient illuminance | Incandescent light: 5,000 ℓx or less at the light-receiving face |
Insulation resistance | 20 MΩ , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
Vibration resistance | 10 to 55 Hz frequency, 0.75 mm0.030 indouble amplitude in X, Y and Z directions for two hours each |
Shock resistance | 300 m / s2acceleration (30 G approx.) in X, Y and Z directions three times each |
Emitting element | Infrared LED (Peak emission wavelength: 850 nm0.034 mil) |
Cable | 0.16 mm25-core heat-resistant PVC cable, 3 m 9.842 ft long |
Cable extension | Extension up to total 50m is possible for 0.3mm2or more, cable |
Material | Enclosure: Polycarbonate alloy Sensing surface: Polycarbonate alloy MS-SFC-1 (Standard mounting bracket): Stainless steel (SUS) |
Accessories | MS-SFC-1 (Standard mounting bracket): 1 set SF4C-TR25 (Test rod): 1 No. |
Title: | Type: | |
---|---|---|
Download general catalog |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.