ZW-XRS2 365159 OMRON Advanced sensors, RS232-PC ZW Cable 2m View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ZW-XRS2 365159 OMRON Advanced sensors, RS232-PC ZW Cable 2m

ZW-XRS2

365159

OMRON

Available

Ship on today

Advanced sensors, RS232-PC ZW Cable 2m

More details


Monitoring Products Measurement

Measurement sensors - Laser displacement sensor - OMRON

Measurement sensors - Laser displacement sensor - ZX2 - OMRON

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



ZW Confocal fiber sensor
Ultra-compact, lightweight sensor measures any material
Ordering information
The ZW confocal fiber displacementsensor delivers stable, non-contact,in-line
measurementof heights, thicknesses and other dimensions. It solves the problems of traditional laser triangulation sensors: deviation between different material and
inclination tolerance. The compact sensing head has no electronic parts to eliminate problems of installation space and mutual interference, electrical/magnetic noise,
temperature rise and mechanical positioning.
• Minimum resolution: 0.01 μm
• Ultra-compact sensing head: 24 × 24 mm weighs only 105 g
• High flexibility robotic cable from sensor to controller, extends32 m
• Mount sensing head one time: no need to re-tune for changing materials
• Separate amplifier provides white LED light source, spectroscope and processor to convert reflected color light to distance
• Automation Software Sysmac Studio simplifies system operation and setting
Sensor heads
TypeMeasuring rangeSpot diameterStatic resolutionOrder code*1
Straight type7±0.3 mm18 μm dia.0.01 μm*2/0.25 μm
ZW-S07
20±1 mm 40 μm dia.0.02 μm*2/0.25 μm ZW-S20
30±3 mm 60 μm dia.0.06 μm*2/0.25 μm ZW-S30
40±6 mm 80 μm dia.0.08 μm*2/0.25 μm ZW-S40
Right-angle type 7±0.3 mm18 μm dia.0.25 μmZW-SR07
20±1 mm 40 μm dia.0.25 μmZW-SR20
40±6 mm 80 μm dia.0.25 μmZW-SR40
*1When ordering, specify the cable length (0.3 m, 2.0 m).
*2The high resolution types are subject to the export control restrictions
Controller with EtherCAT
Power supply Output typeOrder code
24 VDCNPNZW-CE10T/ZW-C10*1
PNPZW-CE15T/ZW-C15*1
*1The high resolution types are subject to the export control restrictions
Note: Controllers with binary outputs are also available (ZW-C10T/-C15T). Pleasecontact your OMRON sales representative for details.
Cable
ItemCable lengthOrder code
Sensor Head - Controller Extension Fiber Cable (flexible cable) (Fiber Adapter ZW-XFC provided)2 mZW-XF02R
5mZW-XF05R
10 m ZW-XF10R
20 m ZW-XF20R
30 m ZW-XF30R Fiber Adapter (between Sensor Head pre-wired cable and Extension Fiber Cable) –ZW-XFC
Parallelcablefor ZW-CE1@ 32-pole*1
2mZW-XCP2E
RS-232C Cable for personal computer2 mZW-XRS2
RS-232C Cable for PLC/programmable terminal 2 mZW-XPT2
*1A parallel cable for Controllers with binary outputs is also available (ZW-XCP2). Please contact yourOMRON sales representative for details.
Automation Software Sysmac Studio
Please purchase a DVD and required numberof licenses the first time you purchase the Sysmac Studio. DVDs and licenses are available individually. Each model of licenses does not include any DVD.
Product nameSpecifications Order code
Number of licensesMedia
Sysmac Studio
The Sysmac Studio provides an integrated development environment to set up,–
DVD SYSMAC-SE200D
Standard Edition
Ver.1.@@ *1
program, debug, and maintain NJ-series controllers and other machine auto- mation controllers, as well as EtherCAT slaves.
Sysmac Studio runs on the following OS.
Windows XP (ServicePack 3 or higher, 32-bit version)/Vista (32-bit version)/
7 (32-bit/64-bit version)
(Media only)
1 license*2
– SYSMAC-SE201L
Sysmac Studio
Measurement Sensor Edition
Ver.1.@@ *3
This softwareprovidesfunctions of the Measurement Sensor Edition. Refer to
Sysmac Catalog (P072) for details such as supported models and functions.
Sysmac Studio Measurement Sensor Edition is a limited license that provides selected functions requiredfor ZW-series Displacement Sensor settings. Because this product is a license only, you need the Sysmac Standard Edition DVD media to install it.
1 license – SYSMAC-ME001L
3 licenses – SYSMAC-ME003L
*1ZW-series is supported by Sysmac Studio version 1.05 or higher.
*2Multi licenses are available for the Sysmac Studio (3, 10, 30, or 50 licenses).
*3Setting Software Smart Monitor ZW is also available(ZW-SW101). Please contact yourOMRON representative for details.
384
ZW Confocal fiber sensor
Setting software Accessories
Item Order code
Smart Monitor ZW ZW-SW101
Recommended EtherCAT communications cables
Item Order code
Fiber Connector CleanerZW-XCL
Use Straight STP (shielded twisted-pair)cable of category 5 or higher with double shielding (braiding and aluminum foil tape) for EtherCAT.
Cable with connectors
Item Recommended manufacturerCable length (m)*1
Order code
Standard type
Cable with connectors on both ends (RJ45/RJ45) Wire gauge and number of pairs:
AWG27, 4-pair Cable
Cable Sheath material: LSZH*2
Cable color: Yellow *3
Rugged type
Cable with connectors on both ends (RJ45/RJ45) Wire gauge and number of pairs:
AWG22, 2-paircable
Rugged type
Cable with connectors on both ends (M12 Straight/RJ45) Wire gauge and number of pairs:
AWG22, 2-paircable
Rugged type
Cable with connectors on both ends (M12 Right-angle/RJ45) Wire gauge and number of pairs:
AWG22, 2-paircable
*1Standard type cables length 0.2, 0.3, 0.5, 1, 1.5, 2, 3, 5, 7.5, 10, 15 and 20m are available.
Rugged type cables length 0.3, 0.5, 1, 2, 3, 5, 10 and 15m are available.
OMRON0.3XS6W-6LSZH8SS30CM-Y
0.5 XS6W-6LSZH8SS50CM-Y
1XS6W-6LSZH8SS100CM-Y
2XS6W-6LSZH8SS200CM-Y
3XS6W-6LSZH8SS300CM-Y
5XS6W-6LSZH8SS500CM-Y OMRON0.3XS5W-T421-AMD-K
0.5 XS5W-T421-BMD-K
1XS5W-T421-CMD-K
2XS5W-T421-DMD-K
5XS5W-T421-GMD-K
10XS5W-T421-JMD-K OMRON0.3XS5W-T421-AMC-K
0.5 XS5W-T421-BMC-K
1XS5W-T421-CMC-K
2XS5W-T421-DMC-K
5XS5W-T421-GMC-K
10XS5W-T421-JMC-K OMRON0.3XS5W-T422-AMC-K
0.5 XS5W-T422-BMC-K
1XS5W-T422-CMC-K
2XS5W-T422-DMC-K
5XS5W-T422-GMC-K
10XS5W-T422-JMC-K
*2The lineup featuresLow Smoke Zero Halogen cables for in-cabinet use and PUR cables for out-of-cabinet use.
*3Cables colors are available in blue, yellow, or Green
Note:For details, refer to Cat.No.G019.
Cables/connectors
Wire gauge and number of pairs: AWG24, 4-pair cable
Industrial switching hubs for Ethernet
Number ofFailure detection Current
Order code
ItemRecommended manufacturerOrder code
ports
consumption
CablesHitachi Cable, Ltd. NETSTAR-C5E SAB 0.5  4P*1
Kuramo Electric Co.KETH-SB*1
SWCC Showa Cable Systems Co. FAE-5004*1
RJ45 connectorsPanduit CorporationMPS588-C*1
*1We recommend you to use above cable and connector together.
3 None 0.22 AW4S1-03B
5 None 0.22 AW4S1-05B SupportedW4S1-05C
Note:Industrial switching hubs are cannot be used for EtherCAT.
EtherCAT junction slaves
Wire gauge and number of pairs: AWG22, 2-pair cable
Number ofPower supply voltage Current
Order code
ItemRecommended manufacturerOrder code
Cables Kuramo Electric Co.KETH-PSB-OMR*1
ports
3 20.4 to 28.8 VDC
(24 VDC –15 to 20%)
consumption
0.08 A GX-JC03
RJ45 Assembly connector
Nihon Electric Wire&Cable Co.,Ltd. PNET/B*1
OMRONXS6G-T421-1*1
6 0.17 A GX-JC06
Note:1 Please do not connect EtherCAT junction slave with OMRON position control unit, Model CJ1W-NC_81/_82.
*1We recommend you to use above cable and connector together.
2 EtherCAT junction slaves cannot be used for EtherNet/IP™ and Ethernet.
Note:Connect both ends of cable shielded wires to the connector hoods.
385
ZW Confocal fiber sensor
Specifications
Sensor head
Item ZW-S07ZW-S20ZW-S30ZW-S40ZW-SR07 ZW-SR20 ZW-SR40
Measuring center distance7 mm 20 mm 30 mm 40 mm 7 mm 20 mm 40 mm Measuring range0.3 mm1 mm 3 mm 6 mm 0.3 mm1 mm 6 mm Static resolution *10.25 μm 0.25 μm 0.25 μm 0.25 μm 0.25 μm 0.25 μm 0.25 μm Linearity *2 0.8 μm 1.2 μm 4.5 μm 7.0 μm 1.1 μm 1.6 μm 9.3 μm Spot diameter *3 Near20 μm dia. 45 μm dia. 70 μm dia. 90 μm dia. 20 μm dia. 45 μm dia. 90 μm dia.
Center 18 μm dia. 40 μm dia. 60 μm dia. 80 μm dia 18 μm dia. 40 μm dia. 80 μm dia
Far20 μm dia. 45 μm dia. 70 μm dia. 90 μm dia 20 μm dia. 45 μm dia. 90 μm dia
Measuring cycle500 μs to 10 ms
Operating ambient illumination Illumination on object surface 10,000 lx or less: incandescent light
Ambient temperature rangeOperating: 0 to 50C, Storage: 15 to 60C (with no icing or condensation)
Ambient humidity range Operating and storage: 35% to 85% (with no condensation)
Degree of protectionIP40 (IEC60529)
Vibration resistance (destructive) 10 to 150 Hz, 0.35 mm single amplitude, 80 min each in X, Y, and Z directions
Shock resistance (destructive) 150 m/s2 3 times each in six directions(up/down, left/right, forward/backward)
Temperature characteristic *40.6 μm/C (0.45 μm/°C)
1.5 μm/C (1.0 μm/°C)
2.8 μm/C (2.0 μm/°C)
4.8 μm/C (3.8 μm/°C)
0.6 μm/C (0.45 μm/°C)
1.5 μm/C (1.0 μm/°C)
4.8 μm/C (3.8 μm/°C)
Materials Case:aluminum die-cast
Fiber cable sheat: PVC CalibrationROM: PC
Fiber cable length0.3 m, 2 m (Flex-resistant cable)
Fiber cable minimum bending radius20 mm
Insulation resistance (Calibration ROM) Between case and all terminals: 20 M (by 250 V megger) Dielectric strength (Calibration ROM)Between case and all terminals: 1,000 VAC, 50/60Hz, 1 min WeightApprox. 105 g (Chassis, fiber cable total)
Accessories included with sensor headInstruction sheet, Fixing screw (M2) for CalibrationROM, Precautions for correct use
*1. Capacity value when Omron standard mirror surface target is measured at the measurement center distance as the average of 4,096 times.
*2. Material setting for the Omron standard mirror surface target: Error from an ideal straight line when measuring on mirror surface.
The reference values for linearity when targets to measure other than the above are as in the table below
Item ZW-S07ZW-S20ZW-S30ZW-S40ZW-SR07 ZW-SR20 ZW-SR40
Glass1.0 μm 1.2 μm 4.5 μm 7.0 μm 1.1 μm 1.6 μm 9.3 μm SUS BA 1.2 μm 1.4 μm 5.5 μm 8.5 μm 1.2 μm 1.8 μm 9.3 μm White ceramic1.6 μm 1.7 μm 6.4 μm 9.5 μm 1.6 μm 1.9 μm 11.0 μm
*3. Capacity value defined by 1/e² (13.5%) of the center optical intensity in the measured area.
*4. Temperature characteristic at the measurement center distance when the sensor head and the target are fastened with an aluminum jig and the sensor head and the controller are set in the same temperature environment.
Figures in parentheses are converted value obtained by subtracting the effect of expansion or contraction of the aluminum jig itself.
Automation software Sysmac Studio
System requirements
Item Condition
Operating system (OS)*1,*2
Windows XP (ServicePack 3 or higher, 32-bit version)/Vista(32-bit version)/7(32-bit/64-bit version)
CPUWindows computers with Celeron540 (1.8 GHz) or faster CPU.
Core i5 M520 (2.4 GHz) or equivalent or faster recommended
Main memory2 GB min.
Recommended video memory/video card for using 3D motion trace
Video memory: 512 MB min.
Video card: Either of the following video cards:
• NVIDIA GeForce 200 Series or higher
• ATI RadeonHD5000 Series or higher
Hard disk At least 1.6 GB of available space
DisplayXGA 1024 × 768, 16 million colors.
WXGA 1280 × 800 min. recommended
Disk driveDVD-ROM drive
Communication portsUSB port corresponded to USB 2.0, or Ethernet port*3
Supported languagesJapanese, English, German, French, Italian, Spanish, simplified Chinese, traditional Chinese, Korean
*1Sysmac Studio operating system precaution: System requirements and hard disk space may vary with the system environment.
*2The following restrictions apply when Sysmac Studio is used with Microsoft Windows Vista or Windows 7.
Some Help files cannot be accessed.
The Help files can be accessedif the Help program distributed by Microsoft for Windows (WinHlp32.exe) is installed. Refer to the Microsoft homepage listed below or contact Microsoft for details on installing the file. (The download page is automatically displayed if the Help files are opened while the user is connected to the Internet.)
http://support.microsoft.com/kb/917607/en-us
*3Refer to the hardware manual for your Controller for hardware connection methods and cables to connect the computer and Controller.
386
ZW Confocal fiber sensor
Setting software Smart Monitor ZW ZW-SW101
System requirements
Item Condition
Operating System(OS)Windows 7 (32 or 64-bit version)
Windows XP (Service Pack3 or more, 32-bit version)
CPU Intel Pentium III, 850 MHz or more (2 GHz or more is recommended.)
Main memory 1 GB or more
Hard disk 50 MB or more
Display1024  768 dots or more, 16 million colors or more
Supported languages Japanese/English
Communication portEthernet port
Controller
Item ZW-CE10TZW-CE15T Input/Output type NPN PNP Number of connected sensor heads 1 per Controller
Sensor head compatibility Available
Light source for measurement White LED
Segment display
Main display11-segment red display, 6 digits
Sub-display 11-segment green display, 6 digits
LED display Status indicatorsHIGH (orange), PASS (green), LOW (orange), STABILITY (green), ZERO (green), ENABLE (green), THRESHOLD-H (orange), THRESHOLD-L (orange), RUN (green)
EtherCAT indicators L/A IN (Link Activity IN) (green), L/O OUT (Link Activity OUT) (green), ECAT RUN (green), ECAT ERR (red)
External interface
Ethernet 100BASE-TX, 10BASE-T, No-protocol communications (TCP/UDP), EtherNet/IPTM
EtherCAT EtherCAT-specific protocol 100BASE-TX
RS-232C 115,200 bps max.
Analog output
Analog voltage output
(OUT1V)
–10 to 10 V, output impedance: 100 
terminal block Analog current output
(OUT1A)
4 to 20 mA, maximum load resistance: 300 
32-pole extension connector
Judgment output
(HIGH1/PASS1/LOW1)
BUSY output (BUSY1) ALARM output (ALARM1) ENABLE output (ENABLE)
Transistor output system Output voltage: 21.6 to 30 VDC Load current: 50 mA or less
Residual voltage when turning ON: 1.2V or less
Leakage voltage when turning OFF: 0.1 mA or les
LED OFF input (LED OFF1)DC input system
ZERO RESET input (ZERO) TIMING output (TIMING1) RESET output (RESET1)
BankSelected bank output
(BANK_OUT 1 to 3)
Selected bank input
(BANK_SEL 1 to 3)
Input voltage: 24 VDC –10% (21.6 to 26.4 VDC) Input current: 7 mA Typ. (24 VDC)
Voltage/Current when turning ON: 19 V/3 mA or more
Voltage/Current when turning OFF: 5 V/1 mA or less
Transistor output system Output voltage: 21.6 to 30 VDC Load current: 50 mA or less
Residual voltage when turning ON: 1.2V or less
Leakage voltage when turning OFF: 0.1 mA or less
DC input system
Input voltage: 21.6 to 26 VDC Input current: 7 mA Typ. (24 VDC)
Voltage/Current when turning ON: 19 V/3 mA or more
Voltage/Current when turning OFF: 5 V/1 mA or less
Main functions
Exposure timeAuto/Manual
Measuring cycle500μs to 10 ms
Material settingStandard/Mirror/Diffusion surfaces
Measurement ItemHeight/Thickness/Calculation
Filtering Median/Average/Differentiation/High pass/Low pass/Band pass
OutputsScaling/Different holds/Zero reset/Logging for a measured value
DisplayMeasured value/Threshold value/Analog output voltage or current value/Judgment result/Resolution/Exposure time
Number of configurable banksMax. 8 banks
Task processMulti-task (up to 4 tasks per bank)
System Save/Initialization/Display measurement information/Communication settings/Sensor Head calibration/Key-lock/ Trigger-key input
RatingsPower supply voltage21.6 to 26.4VDC (including ripple)
Current consumption 600 mA max.
Insulation resistanceAcross all lead wires and controller case: 20 M(by 250 V megger)
Dialectic strength Across all lead wires and controller case: 1,000 VAC, 50/60 Hz, 1 min.
Environmen- tal
Degree of protectionIP20 (IEC60529)
Vibration resistance (destructive) 10 to 55 Hz, 0.35-mm single amplitude, 50 min each in X, Y, and Z directions Shock resistance (destructive) 150 m/s2, 3 times each in six directions(up/down, left/right, forward/backward) Ambient temperature Operating: 0 to 40C
Storage: –15 to 60C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Grounding D-type grounding (Grounding resistance of 100  or less) Note: For conventional Class D grounding
MaterialsCase: PC
387
ZW Confocal fiber sensor
Item ZW-CE10T ZW-CE15T Weight Approx. 750 g (main unit only), approx. 150 g (Parallel cable)
Accessories included with controller Instruction sheet, Member registration sheet, Parallel cable ZW-XCP2E
Note: Controllers with binary outputs are also available (ZW-C10T/-C15T). Pleasecontact your OMRON sales representative for details.
ZW series EtherCAT communications specifications
Item Specification
Communications standard IEC61158 Type12
Physical layer 100BASE-TX (IEEE802.3)
Connectors RJ45  2
ECAT IN: EtherCAT input
ECAT OUT: EtherCAT output
Communications media Category 5 or higher (cable with double, aluminum tape and braided shielding) is recommended.
Communications distance Distance between nodes: 100 m max.
Process data Variable PDO mapping
Mailbox (CoE)Emergency messages, SDO requests, SDO responses, and SDO information
Distributed clock Synchronization in DC mode.
LED displayL/A IN (Link/Activity IN)  1, AL/A OUT (Link/Activity OUT)  1, AECAT RUN  1, AECAT ERR  1
388

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoZW RS-232 cable for PC 365159 - OMRON - ZW-XRS2 - 365159English205 Kbytespdf1-mostradoZW RS-232 cable for PC 365159 - OMRON - ZW-XRS2 - 365159
pdf1-ZW RS-232 cable for PC 365159 - OMRON - ZW-XRS2 - 365159English0 bytespdf1-mostradoZW RS-232 cable for PC 365159 - OMRON - ZW-XRS2 - 365159
pdf2-mostradoZW RS-232 cable for PC 365159 - OMRON - ZW-XRS2 - 365159English1 Mbytespdf1-mostradoZW RS-232 cable for PC 365159 - OMRON - ZW-XRS2 - 365159

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review