ZS-HLDC41 223618 OMRON Advanced sensors, multitasking PNP Amplifier View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ZS-HLDC41 223618 OMRON Advanced sensors, multitasking PNP Amplifier

ZS-HLDC41

223618

OMRON

Available

Ship on today

Advanced sensors, multitasking PNP Amplifier

More details


Monitoring Products Measurement

Measurement sensors - Laser displacement sensor - OMRON

Measurement sensors - Laser displacement sensor - ZS-HL - OMRON

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



ZS-HL Laser displacement sensor
The scalable high-precision laser measurement sensor
The ZS laser sensor family provides outstanding measurement performance on all kind of materials. Its huge range of sensor heads and scalable concept makes it a versatile platform for all high precision sensing applications.
• Highest resolution and dynamic sensing range for all surfaces
• Modular and scalable platform concept for up to 9 sensors
• Easy to use, install and maintain for all user levels
• Fast response time of 110 μs
• Multi-tasking capability – manages up to 4 measurement tools in one controller
Ordering information
Sensors
ZS-HL-series sensor heads
Optical system Sensing distance Beam shape Beam diameter Resolution*1
Order code
Regular reflective models 20±1 mm Line beam 1.0 mm × 20 μm 0.25 μm ZS-HLDS2T
25±2 mm 2.2 mm × 45 μm 0.6 μm ZS-HLDS2VT Diffuse reflective models 50±5 mm 1.0 mm × 30 μm 0.25 μm ZS-HLDS5T
100±20 mm 3.5 mm × 60 μm 1 μm ZS-HLDS10
600±350 mm 16 mm × 0.3 mm 8 μm ZS-HLDS60
1500±500 mm 40 mm × 1.5 mm 500 μm ZS-HLDS150
*1 Refer to the table of ratings and specifications for details.
ZS-HL-series sensor heads (for nozzle gaps) also compatible with ZS-L controller
Optical system Sensing distance Beam shape Beam diameter Resolution*1
Order code
Regular reflective models 10±0.5 mm Line beam 900x25 μm 0.25 μm ZS-LD10GT
15±0.75 mm ZS-LD15GT
*1 Refer to the table of ratings and specifications for details.
ZS-L-series sensor heads
Optical system Sensing distance Beam shape Beam diameter Resolution*1
Order code
Regular reflective models 20±1 mm Line beam 900 × 25 μm 0.25 μm ZS-LD20T Spot beam 25 μm dia. ZS-LD20ST
40±2.5 mm Line beam 2000 × 35 μm ZS-LD40T Diffuse reflective models 50±5 mm Line beam 900 × 60 μm 0.8 μm ZS-LD50
Spot beam 50 μm dia. ZS-LD50S
80±15 mm Line beam 900 × 60 μm 2 μm ZS-LD80
130±15 mm Line beam 600 × 70 μm 3 μm ZS-LD130
200 ±50 mm Line beam 900 × 100 μm 5 μm ZS-LD200
350 ±135 mm Spot beam 240 μm dia. 20 μm ZS-LD350S
*1 This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of samples to average is set to 128 and the measuring mode is set to the high-resolution mode. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode.
ZS-HL-series sensor controllers Multi-controllers
Supply voltage Control outputs Order code
24 VDC NPN outputs ZS-HLDC11
PNP outputs ZS-HLDC41
ZS-HLDC41A
(incl. USB cable + Smart monitor)
Accessories (sold separately)
Controller link
Item Order code
Controller link ZS-XCN
Panel mount adapter
Model Order code
For 1st controller ZS-XPM1
For expansion (from 2nd controller on) ZS-XPM2
Cables for connecting to a Personal Computer
Type Quantity Order code
RS-232C 1 ZS-XRS2
USB 1 ZS-XUSB2
Supply voltage Control outputs Order code
24 VDC NPN outputs ZS-MDC11
PNP outputs ZS-MDC41
Data storage units
Supply voltage Control outputs Order code
24 VDC NPN outputs ZS-DSU11
PNP outputs ZS-DSU41
Extension cables for sensor heads
Cable length Quantity Order code
1m 1 ZS-XC1A
4m 1 ZS-XC4A
5m 1 ZS-XC5B*1,*2
8m 1 ZS-XC8A
10 m 1 ZS-XC10B*1
*1 Up to two ZS-XC_B cables can be connected (22 m max.).
*2 A robot cable (ZS-XC5BR) is also available.
376
ZS-HL Laser displacement sensor
Logging software
Item Order code
Smart monitor zero professional ZS-SW11E
Memory card
Model Order code
64 MB F160-N64S(S)
128 MB QM300-N128S
256 MB F160-N256S
Safety precautions for using laser equipment
Laser Label Indications
Attach the following warning label to the side of the
ZS-L-series Sensor Head.
Specifications
Sensor heads
ZS-HL-series sensor heads
Item ZS-HLDS2T ZS-HLDS2VT ZS-HLDS5T ZS-HLDS10 ZS-HLDS60 ZS-HLDS150
Applicable controllers ZS-HLDC series
Optical system Regular reflection
Diffuse reflec- tion
Regular reflection
Regular reflection
Diffuse reflec- tion
Regular reflection
Diffuse reflec- tion
Diffuse reflec- tion
Diffuse reflec- tion
Measuring center distance 20 mm 5.2 mm 25 mm 44 mm 50 mm 94 mm 100 mm 600 mm 1,500 mm Measuring range ±1 mm ±1 mm ±2 mm ±4 mm ±5 mm ±16 mm ±20 mm ±350 mm ±500 mm Light source Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Clas Visible semiconductor laser
(wavelength 658 nm, 1 mW max.,
Class 2)
Beam shape Line beam
Beam diameter*1
1.0 mmx20 μm 2.2 mmx45 μm 1.0 mmx30 μm 3.5 mmx60 μm 0.3 mmx16 mm 1.5 mmx40 mm
Linearity*2
±0.05% F.S. ±0.2 %F.S. ±0.1% F.S. ±0.07 %F.S. (250 mm to
750 mm)
±0.1% F.S. (750 mm to
950 mm)
±0.2 %F.S.
Resolution*3
0.25 μm
(No. of samples to average: 256)
0.5 μm
(No. of samples to average: 128)
0.25 μm
(No. of samples to average: 512)
1 μm
(No. of samples to average: 64)
8 μm (average 64) (at 250 mm)
40 μm (average 64) (at 600 mm)
500 μm
(average 64)
Temperature characteristic*4 0.01% F.S./°C 0.1% F.S./°C 0.01% F.S./°C
Sampling cycle 110 μs (high-speed mode), 500 μs (standard mode), 2.2 ms (high-precision mode), 4.4 ms (high-sensitivity mode)
Indicators NEAR
indicator
Lits near the measurement center, and nearer than the measurement center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
FAR indicator Lits near the measurement center, and further than the measurement center distance inside the measuring range.
Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Operating ambient illumination
Illumination on received light surface 3,000 lx or less (incandescent light) Illumination on received light surface 1,000 lx or less (incan- descent light)
Illumination on received light surface 500 lx or less (incandes- cent light)
Ambient temperature Operating: 0 to 50°C, storage: –15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Degree of protection IP64 IP67 Cable length 0.5 m: IP66, cable length 2 m: IP67 IP66 (IEC60529)
Vibration resistance
(destructive)
10 to 150 Hz, 0.7 mm double amplitude, 80 min each in X, Y, and Z directions
Shock resistance (destructive) 150 m/s² 3 times each in six directions (up/down, left/right, forward/backward)
Materials Case: aluminum die-cast, front cover: glass
Cable length 0.5 m, 2 m 2 m 0.5 m, 2 m
Weight Approx. 350 g Approx. 600 g Approx. 800 g
*1 Defined as 1/e² (13.5%) of the center optical intensity in the measurement center distance. The beam diameter is sometimes influenced by the ambient conditions of the workpiece such as leaked light from the main beam.
*2 This is the error on the measured value with respect to an ideal straight line. Linear curve may change according to the workpiece. The following lists the workpieces
Model Diffusive reflection Mirror reflection
ZS-HLDS2T SUS block Glass ZS-HLDS5T/HLDS10 White alumina ceramic Glass ZS-HLDS60/HLDS150 White alumina ceramic –
ZS-HLDS2VT – Glass
*3 This is the “peak-to-peak” displacement conversion value of the displacement output in the measurement center distance when high-resolution mode and the average number in the table are set (For ZS-HLDS60, the maximum resolution at 250 mm is also included). The following lists the workpieces.
Model Diffusive reflection Mirror reflection
ZS-HLDS2T SUS block Glass ZS-HLDS5T White alumina ceramic Glass ZS-HLDS10 White alumina ceramic
ZS-HLDS60/HLDS150 White alumina ceramic –
ZS-HLDS2VT – Glass
*4 Value obtained when the sensor part and object part are fixed with an aluminum jig.
377
ZS-HL Laser displacement sensor
ZS-L-series sensor heads
Item ZS-LD20T ZS-LD20ST ZS-LD40T ZS-LD10GT ZS-LD15GT Applicable controllers ZS-HLDC/LDC series
Optical system Regular reflection Diffuse reflection Regular reflection Diffuse reflection Regular reflection Diffuse reflection Regular reflection Measuring center distance 20 mm 6.3 mm 20 mm 6.3 mm 40 mm 30 mm 10 mm 15 mm Measuring range ±1 mm ±1 mm ±1 mm ±1 mm ±2.5 mm ±2 mm ±0.5 mm ±0.75 mm Light source Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2)
Beam shape Line beam Spot beam Line beam
Beam diameter*1
Linearity*2
Resolution*3
900 x 25 μm 25 μm dia. 2,000 x 35 μm Approx. 25 x 900 μm
±0.1%F.S
0.25 μm 0.25 μm 0.4 μm 0.25 μm 0.25 μm
Temperature characteristic*4 0.04% FS/°C 0.04% FS/°C 0.02% FS/°C 0.04% FS/°C
Sampling cycle*5
Indicators NEAR
indicator
FAR
indicator
Operating ambient illumination
110 μs (high-speed mode), 500 μs (standard mode), 2.2 ms (high-precision mode), 4.4 ms (high-sensitivity mode)
Lights near the measuring center distance, and nearer than the measuring center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Lights near the measuring center distance, and further than the measuring center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Illumination on received light surface: 3,000 lx or less (incandescent light)
Ambient temperature Operating: 0 to 50°C, storage: -15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Degree of protection Cable length 0.5 m: IP66, cable length 2 m: IP67 IP40
Materials Case: Aluminum die-cast, front cover: Glass
Cable length 0.5 m, 2 m
Weight Approx. 350 g Approx. 400 g
Accessories Laser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (2), insure Locks (2), instruction sheet Laser safety labels (1 each for JIS/ EN),ferrite cores (2), insure locks (2)
*1 Defined as 1/e² (13.5%) of the center optical intensity at the actual measurement center distance (effective value). The beam diameter is sometimes influenced by the ambient conditions of the workpiece, such as leaked light from the main beam.
*2 This is the error in the measured value with respect to an ideal straight line. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection
mode of the ZS-LD20T/40T/50. Linearity may change according to the workpiece.
*3 This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of samples to average is set to 128 and the measuring mode is set to the high-resolution mode. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode.
*4 This is the value obtained at the measuring center distance when the Sensor and workpiece are fixed by an aluminum jig.
*5 This value is obtained when the measuring mode is set to the high-speed mode.
ZS-L-series sensor heads
Item ZS-LD50 ZS-LD50S ZS-LD80 ZS-LD130 ZS-LD200 ZS-LD350S Applicable controllers ZS-HLDC/LDC series
Optical system (reflection) Diffuse Regular Diffuse Regular Diffuse Regular Diffuse Regular Diffuse Regular Diffuse Measuring center distance 50 mm 47 mm 50 mm 47 mm 80 mm 78 mm 130 mm 130 mm 200 mm 200 mm 350 mm Measuring range ±5 mm ±4 mm ±5 mm ±4 mm ±15 mm ±14 mm ±15 mm ±12 mm ±50 mm ±48 mm ±135 mm Light source Visible semiconductor laser (wavelength: 650 nm, 1 mW max., JIS Class 2)
Beam shape Line beam Spot beam Line beam Line beam Line beam Spot beam
Beam diameter*1
Linearity*2
Resolution*3
900 x 60 μm 50 μm dia. 900 x 60 μm 600 x 70 μm 900 x 100 μm 240 μm dia.
±0.1%F.S. ±0.25%F.S. ±0.1%F.S. ±0.25%F.S. ±0.04%F.S.
0.8 μm 0.8 μm 2 μm 3 μm 5 μm 20 μm
Temperature characteristic*4 0.02% FS/°C 0.02% FS/°C 0.01% FS/°C 0.02% FS/°C 0.02% FS/°C 0.04% FS/°C
Sampling cycle*5
Indicators NEAR
indicator
FAR
indicator
110 μs (high-speed mode), 500 μs (standard mode), 2.2 ms (high-precision mode), 4.4 ms (high-sensitivity mode)
Lights near the measuring center distance, and nearer than the measuring center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Lights near the measuring center distance, and further than the measuring center distance inside the measuring range. Flashes when the measurement target is outside of the measuring range or when the received light amount is insufficient.
Operating ambient
Illumination on received light surface: 3,000 lx or less (incandescent light) Illumination on received
Illumination on received light surface:
illumination
Ambient temperature
Operating: 0 to 50°C, storage: –15 to 60°C (with no icing or condensation)
light surface: 2,000 lx or less 3,000 lx or less (incandescent light) (incandescent light)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Degree of protection Cable length 0.5 m: IP66, cable length 2 m: IP67
Materials Case: Aluminum die-cast, front cover: Glass
Cable length 0.5 m, 2 m
Weight Approx. 350 g
Accessories Laser labels (1 each for JIS/EN, 3 for FDA), ferrite cores (2), insure Locks (2), instruction sheet
*1 Defined as 1/e² (13.5%) of the center optical intensity at the actual measurement center distance (effective value). The beam diameter is sometimes influenced by the ambient conditions of the workpiece, such as leaked light from the main beam.
*2 This is the error in the measured value with respect to an ideal straight line. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode of the ZS-LD20T/40T/50. Linearity may change according to the workpiece.
*3 This is the peak-to-peak displacement conversion value in the displacement output at the measuring center distance in high-precision mode when the number of samples to average is set
to 128 and the measuring mode is set to the high-resolution mode. The standard workpiece is white aluminum ceramics in diffuse reflection mode and glass in the regular reflection mode.
*4 This is the value obtained at the measuring center distance when the sensor and workpiece are fixed by an aluminum jig.
*5 This value is obtained when the measuring mode is set to the high-speed mode.
378
ZS-HL Laser displacement sensor
Sensor controllers
ZS-HL-series sensor controllers
Item ZS-HLDC11 ZS-HLDC41
NPN/PNP NPN PNP
No. of samples to average 1, 2, 4, 8, 16, 32, 64, 128, 256, 512, 1,024, 2,048, or 4,096
Number of mounted sensors 1 per sensor controller
External
Connection method Serial I/O: connector, other: pre-wired (standard cable length: 2 m)
interface Serial I/O USB 2.0 1 port, full speed (12 Mbps max.), MINI-B
RS-232C 1 port, 115,200 bps. max.
Output Judgement output HIGH/PASS/LOW 3 outputs
NPN open collector, 30 VDC, 50 mA max., residual voltage 1.2 V max
HIGH/PASS/LOW: 3 outputs
PNP open collector, 50 mA max., residual voltage 1.2 V max
Linear output Selectable from 2 types of output, voltage or current (selected by slide switch on bottom).
Voltage output: .10 to 10 V, output impedance: 40 
Current output: 4 to 20 mA
Inputs Laser OFF,
ON: Short-circuited with 0 V terminal or 1.5 V or less
ON: Short-circuited to supply voltage or within 1.5 V of supply voltage.
ZERO reset timing, OFF: Open (leakage current: 0.1 mA max.)
RESET
OFF: Open (leakage current: 0.1 mA max.)
Functions Display: Measured value, threshold value, voltage/current, received light amount, and resolution/terminal block output
Sensing: Mode, gain, measurement object, head installation
Measurement point: Average, peak, bottom, thickness, step, and calculations
Filter: Smooth, average, and differentiation
Outputs: Scaling, various hold values, and zero reset
I/O settings: Linear (focus/correction), judgments (hysteresis and timer), non-measurement, and bank (switching and clear) System: Save, initialization, measurement information display, communications settings, key lock, language, and data load Task: Single task or multitask (up to 4)
Status indicators HIGH (orange), PASS (green), LOW (orange), LDON (green), ZERO (green), and ENABLE (green)
Segment display Main digital 8-segment red LED, 6 digits
Sub-digital 8-segment green LEDs, 6 digits
LCD 16 digitsx2 rows, color of characters: green, resolution per character: 5x8 pixel matrix
Setting inputs Setting keys Direction keys (UP, DOWN, LEFT, and RIGHT), SET key, ESC key, MENU key, and function keys (1 to 4)
Slide switch Threshold switch (2 states: High/Low), mode switch (3 states: FUN, TEACH, and RUN)
Power supply voltage 21.6 V to 26.4 VDC (including ripple)
Current consumption 0.5 A max. (when sensor head is connected)
Ambient temperature Operating: 0 to 50°C, storage: –15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Degree of protection IP20
Materials Case: Polycarbonate (PC)
Weight Approx. 280 g (excluding packing materials and accessories)
Accessories Ferrite core (1), instruction sheet
ZS-MDC11/MDC41 multi controllers
Basic specifications are the same as those for the sensor controllers. The following points, however, are different.
(1) Sensor heads cannot be connected.
(2) A maximum 9 of controllers can be connected. Control link units are required to connect controllers.
(3) Processing functions between controllers: Math functions
Controller link unit
Connection using the ZS-XCN
Controller link unit
Data storage units
Data storage unit
Multi-controller
Sensor controllers
Sensor controllers Model ZS-DSU11 ZS-DSU41
Number of mounted censor heads Cannot be connected
Number of connectable controllers 10 controllers max. (ZS-MDC: 1 controller, ZS-HLDC: 9 controllers max.)*1
Connectable controllers ZS-HLDC_ _ , ZS-MDC
External
Connection method Serial I/O: connector, other: pre-wired (standard cable length: 2 m)
interface Serial I/O USB 2.0 1 port, full speed (12 Mbps), MINI-B
RS-232C 1 port, 115,200 bps max.
Outputs 3 outputs: HIGH, PASS, and LOW
NPN open-collector, 30 VDC, 50 mA max., residual voltage: 1.2 V max.
Inputs ON: Short-circuited with 0V terminal or 1.5 V or less
OFF: Open (leakage current: 0.1 mA max.)
Data resolution 32 bits
3 outputs: HIGH, PASS, and LOW PNP open-collector, 50 mA max., residual voltage: 1.2 V max.
ON: Short-circuited to supply voltage or within 1.5 V of supply voltage
OFF: Open (leakage current: 0.1 mA max.)
Function Logging trigger functions Start and stop triggers can be set separately external triggers, data triggers (self-triggers), and time triggers
s Other functions External banks, alarm outputs, saved data format customization, and clock
Status indicators OUT (orange), PWR (green), ACCESS (orange), and ERR (red)
Segment display 8-segment green LEDs, 6 digits
LCD 16 digitsx2 rows, color of characters: green, resolution per character: 5x8 pixel matrix
Setting inputs Setting keys Direction keys (UP, DOWN, LEFT, and RIGHT), SET key, ESC key, MENU key, and function keys (1 to 4)
Slide switch Threshold switch (2 states: High/Low), mode switch (3 states: FUN, TEACH, and RUN)
379
ZS-HL Laser displacement sensor
Sensor controllers Model ZS-DSU11 ZS-DSU41
Power supply voltage 21.6 V to 26.4 VDC (including ripple)
Current consumption 0.5 A max.
Ambient temperature Operating: 0 to 50°C, storage: –15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Materials Case: Polycarbonate (PC)
Weight Approx. 280 g (excluding packing materials and accessories)
Accessories Ferrite core (1) instruction sheet, tools for data storage unit: CSV file converter for data storage unit, smart analyzer macro edition
(Excel macros for analysis of collected data)
*1 Control link units are required to connect controllers.
380

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoZS-H Controller, Analogue output and PNP digital outputs - OMRON - ZS-HLDC41 - 223618English261 Kbytespdf1-mostradoZS-H Controller, Analogue output and PNP digital outputs - OMRON - ZS-HLDC41 - 223618
pdf1-ZS-H Controller, Analogue output and PNP digital outputs - OMRON - ZS-HLDC41 - 223618English6 Mbytespdf1-mostradoZS-H Controller, Analogue output and PNP digital outputs - OMRON - ZS-HLDC41 - 223618
pdf2-mostradoZS-H Controller, Analogue output and PNP digital outputs - OMRON - ZS-HLDC41 - 223618English1 Mbytespdf1-mostradoZS-H Controller, Analogue output and PNP digital outputs - OMRON - ZS-HLDC41 - 223618

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or