ZG2-WDC41A 257544 OMRON Advanced sensors, advanced multifunction laser ZG2 PNP + Controller Software View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

ZG2-WDC41A 257544 OMRON Advanced sensors, advanced multifunction laser ZG2 PNP + Controller Software

ZG2-WDC41A

257544

OMRON

Available

Ship on today

Advanced sensors, advanced multifunction laser ZG2 PNP + Controller Software

More details


Monitoring Products Measurement

Measurement sensors - Profile sensor - OMRON

Measurement sensors - Profile sensor - ZG2 - OMRON

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



ZG2 Profile sensor
Easy profile measurement – “teach&go”
The ZG2 enables precise shape measurement on challenging materials and surfaces. An easy and intuitive user interface enables efficient installation, setup and operation. A built-in LCD monitor indicates the measurement result in real time.
• Easy to use – intuitive user interface
• Live – built-in LCD monitor for setup and immediate profile display
• Versatile – 18 measurement tools
• Accurate – 5 μm resolution (3 mm / 631 pixels)
• Wide profiles – up to 70 mm
Ordering information
Sensor heads
Optical method Sensing distance Resolution Order code
Heigt direction Width direction Hight direction Width direction
Diffuse reflective 21048 mm 70 mm 6 μm 111 μm ZG2-WDS70
Diffuse reflective 10012 mm 22 mm 2.5 μm 35 μm ZG2-WDS22
Diffuse reflective 503 mm 8 mm 1 μm 13 μm ZG2-WDS8T Regular reflective 20.5 mm 3 mm 0.25 μm 5 μm ZG2-WDS3VT
Note: - For details, refer the ratings and specifications table.
- Designate the cable length (0.5 m, 2 m) when ordering.
Sensor controllers
Power supply Output type Order code
24 VDC NPN ZG2-WDC11A*1
PNP ZG2-WDC41A
*1 Setup support software for PC is attached
Accessories (order separately)
Real-time parallel output unit
Output type Order code
Parallel mounting adaptor
Order code
NPN ZG-RPD11
PNP ZG-RPD41
For 1 unit ZS-XPM1
For 2 units or more ZS-XPM2
RS-232C cable
Connecting device Order code
For personal computer connection (2 m) ZS-XRS2
For PLC/PT connection (2 m) ZS-XPT2
Sensor head extension cable
Name Order code
3 m extension cable ZG2-XC3CR
8 m extension cable ZG2-XC8CR
15 m extension cable ZG2-XC15CR
25 m extension cable ZG2-XC25CR Digital equalizer (relay device) ZG2-XEQ
0.2 m digital equalizer connection cable ZG2-XC02D
Controller link unit
Item Order code
Controller link unit ZS-XCN
Memory card
Capacity Order code
128 MB F160-N1285
256 MB F160-N2565
393
ZG2 Profile sensor
Specifications
Sensor heads
Item ZG2-WDS70 ZG2-WDS22 ZG2-WDS8T ZG2-WDS3VT
Optical system Diffuse reflective Diffuse reflective
Regular reflective
Diffuse reflective
Regular reflective
Regular reflective
Diffuse reflective
Measurement range Height direction 210±48 mm
(In the high-precision mode)
100±12 mm 94±10 mm 50±3 mm 44±2 mm 22.3±0.5 mm 10.6±0.4 mm
Width direction (typical) 70 mm 22 mm 8 mm 3 mm
Resolution Height direction*1 6 μm 2.5 μm 1 μm 0.25 μm
Width direction 111 μm
(70 mm/631 pixels)
Linearity (in the height direction)*2 ±0.1% F.S.
35 μm
(22 mm/631 pixels)
13 μm
(8 mm/631 pixels)
5 μm
(3 mm/631 pixels)
Temperature characteristic*3 0.02% F.S./°C 0.03% F.S./°C 0.08% F.S./°C
Light source Type Visible semiconductor laser
Wavelength 658 nm 650 nm
Output 5 mW max. output, 1 mW max. exposure (without using optical instruments) 1 mW max.
Laser class Class 2M of EN60825-1 / IEC60825-1
Class IIIB of FDA (21CFR 1040.10 and 1040.11)
Class 2 of EN60825-1 / IEC60825-1
Class II of FDA (21CFR 1040.10 and 1040.11)
Beam shape (at measurement center distance)*4 120 μm × 75 mm (typical) 60 μm × 45 mm (typical) 30 μm × 24 mm (typical) 25 μm × 4 mm (typical)
LED STANDBY: Lights when laser irradiation preparation is complete (indication color: green) LD_ON: Lights when the laser is irradiating (indication color: green)
Measurement object Surface of non-transparent objects
Surface of non-transparent/transparent objects
Environmental resistance
Ambient light intensity Illumination on the photo-receiving face 7,000 lx max.: Incandescent lamp Ambient temperature Operating: 0 to 50°C, Storage: –15 to 60°C (with no icing or condensation) Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Degree of protection IP66 (IEC60529) IP67 (IEC60529)
Vibration resistance (destruction) 10 to 150 Hz with 0.35 mm single amplitude for 80 min each in X, Y, and Z directions
Shock resistance (destruction) 150 m/s², 3 times each in 6 directions (up / down, right / left, forward / backward)
Materials Case: Aluminum diecast, Front cover: Glass, Cable insulation : Heat-resistive polyvinyl chloride (PVC), Connector: Zinc alloy or brass
Cable length 0.5 m, 2 m (flexible cable)
Weight Approx. 650 g Approx. 500 g Approx. 300 g
Accessories Laser labels (EN : 2 labels, FDA : 3 labels), Ferrite core (1), Instruction manual
*1 Obtained by setting an Omron standard measurement object at the measurement center distance and determing the average height of the beam line. The conditions are given in the table below. However, satisfactory resolution cannot be attained in strong electromagnetic fields.The minimum resolution of the ZG2-WDS8T/WDS3VT is 0.25 ƒÊm, even when the average number of operations is increased. Resolution does not go any lower.
Model CCD Mode Average No. of operations Measurement object
Regular reflective Diffuse reflective
ZG2-WDS70/WDS22/WDS8T Standard mode 64 Omron standard white alumina ceramic object
ZG2-WDS3VT Standard mode Omron standard mirrored object Omron standard diffuse reflective object
*2 The tolerance for an ideal straight line obtained by determing the average height of an Omron standard measurement object for the beam line. The CCD high-resolution mode is used. Lin- earity varies depending on the measurement object.
Model Measurement object
Regular reflective Diffuse reflective
ZG2-WDS70/WDS22/WDS8T Omron standard white alumina ceramic object
ZG2-WDS3VT Omron standard mirrored object Omron standard diffuse reflective object
*3 A value attained by using an aluminum jig to secure the distance between the Sensor head and the measurement object. The CCD standard mode is used.
*4 Defined as 1/e2 (13.5%) of the center light intensity. This may be influenced when light leakage also exists outside the defined area and the reflectivity of the light around the measurement object is higher than that of the measurement object.
394
ZG2 Profile sensor
Sensor controllers
Item ZG2-WDC11/WDC11A ZG2-WDC41/WDC41A Input/output type NPN PNP
No. of connectable Sensor Heads 1 per Controller
No. of connectable Controllers 2
Measurement cycle *1
16 ms (high-precision mode), 8 ms (standard mode), 5 ms (high-speed mode)
Min. display unit 10 nm
Display range –999.99999 to 999.99999
Display LCD monitor 1.8-inch TFT color LCD (557x234 pixels)
LEDs • Judgment indicators for each task (indication color: orange): T1, T2, T3, T4
• Laser indicator (indication color: green): LD_ON
• Zero reset indicator (indication color: green): ZERO
• Trigger indicators (indication color: green): TRIG
External interface
Input/output signal lines
Analog outputs Select voltage or current (using the sliding switch on the bottom surface)
• Voltage output: 10 to 10 V, output impedance: 40 
• Current output: 4 to 20 mA, maximum load resistance: 300 
Judgment output
(ALL-PASSING/ERROR)
Trigger auxiliary output
(ENABLE/GATE)
NPN open collector
30 VDC, 50 mA max. Residual voltage: 1.2 V max.
PNP open collector
50 mA max.
Residual voltage: 1.2 V max.
Laser stop input (LD-OFF) ON: O V short or 1.5 V max.
ON: Power supply voltage short or
Zero reset input (ZERO) Measurement trigger input (TRIG) Bank switching input (BANK A, B)
OFF: Open (leakage current: 0.1 mA max.)
power supply voltage –1.5 V max. OFF: Open (leakage current: 0.1 mA max.)
Serial I/O USB2.0 1 port, full speed (12 Mbps), MINI-B
RS-232C 1 port, 115,200 bps max.
Parall output*2
Output 18 - terminal
Main functions No. of settings banks 16
Sensitivity adjustment Multi, High-speed multi, Auto, Fixed
Measurement items Height, 2-point Step, 3-point Step, Edge position, Edge width, Angle, Intersection coordinates, Intersection angle, Sectional area
(up to eight items can be measured simultaneously)
Auxiliary functions Filter, Laser power adjustment, Position correction (height, position, lope), Linked operation, Point of inflection measurement
Profiles saved 16 profiles (1 profile per bank)
Trigger modes External trigger/continuous
Ratings Power supply voltage 21.6 to 26.4 VDC (including ripple current)
Current consumption 0.8 A max. (per sensor head)
Insulation resistance 20 M at 250 V between lead wires and Controller case
Dielectric strength 1,000 VAC, 50 / 60 Hz for 1 min between lead wires and Controller case
Environmental resistance Ambient temperature Operating: 0 to 50°C, Storage: –15 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Degree of protection IP20 (IEC 60529)
Vibration resistance (destruction) Vibration frequency: 10 to 150 Hz, single amplitude: 0.35 mm, acceleration: 50 m/s²
Shock resistance (destruction) 150 m/s², 3 times each in 6 directions (up/down, right/left, forward/backward)
Material Case: Polycarbonate (PC),
Cable insulation : Heat-resistive polyvinyl chloride (PCV)
Cable length 2 m
Weight Approx. 300 g (including cable) (Packed state: Approx. 450 g)
Accessories ZG2-WDC_1: Large Ferrite Core (1 piece), Instruction Manual
ZG2-WDC_1A: Large Ferrite Core (1 piece), Small Ferrite Core (2 pieces), Instruction Manual, Setup Support Software (CD-ROM), USB cable (1 m)
*1 The image input periods listed here are for fixed/auto sensitivity. The image input period will be longer for multi-sensitivity, high-speed multi-sensitivity, or other settings. When the high- power mode is ON, the shortest image input period is 95 ms regardless of the setting of the CCD mode. Use the eco monitor in the RUN mode to determine the actual image input period.
*2 when ZG-RPD is mounted
395
ZG2 Profile sensor
Data storage unit
Item ZG2-DSU11 ZG2-DSU41
Input/output type NPN PNP
No. of connectable Controllers 2*1
Connectable controllers ZG2-WDC11/WDC41
External interface
Input/output signal lines
Inputting starting/
terminating logging
Judgment output
(HIGH/PASS/LOW/ERROR)
ON: O V short or 1.5 V max.
OFF: Open (ileakage current : 0.1 mA max.)
NPN open collector
30 VDC, 50 mA max.
Residual voltage : 1.2 V max.
ON: Power supply voltage short or power supply voltage
–1.5 V max.
OFF: Open (leakage current: 0.1 mA max.)
PNP open collector
50 mA max.
Residual voltage: 1.2 V max.
Serial I/O USB2.0 1 port, full speed (12 Mbps), MINI-B
RS-232C 1 port, 115,200 bps max.
Functions No. of logged Memory of the main unit Profiles saved: 5,120 profiles
data*2
Memory card (256 MB)*4
Measurement values saved: 65,000 values max.*3
Profiles saved: 35,328 profiles max. (256 profiles x 138 files)
Measurement values saved: 7,150,000 values max. (65,000 values x 110 files)
Logging trigger functions External triggers, data triggers (self-triggers), and time triggers
External banks functions 4096
Other functions Alarm output functions
Ratings Power supply voltage 21.6 to 26.4 VDC (including ripple current)
Current consumption 0.5 A max.
Environmental resistance Ambient temperature Operating: 0 to 50°C, Storage: 0 to 60°C (with no icing or condensation)
Ambient humidity Operating and storage: 35% to 85% (with no condensation)
Material Case : Polycarbonate (PC)
Cable length 2 m
Weight Approx. 280 g
Accessories Ferrite Core (1 piece), Instruction Manual
*1 The controller link unit is necessary for linking.
*2 Data is saved in the memory of the main unit during logging. The data is automatically saved in a memory card after logging is completed. The maximum number of logging differs according to set conditions. For details, refer to the Users Manual.
*3 Measurement values for 65,000 measurements can be saved even when two sensor controllers are connected and each performs eight tasks.
*4 The value is the maximum number achieved in the following conditions:
• One sensor controller performs one measurement task.
• Either profiles or measurement values are logged.
396

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoZG Profile sensor controller, PNP, 24 VDC, Includes Smart Monitor ZG Software. - OMRON - ZG2-WDC4English178 Kbytespdf1-mostradoZG Profile sensor controller, PNP, 24 VDC, Includes Smart Monitor ZG Software. - OMRON - ZG2-WDC4
pdf2-mostradoZG Profile sensor controller, PNP, 24 VDC, Includes Smart Monitor ZG Software. - OMRON - ZG2-WDC4English814 Kbytespdf1-mostradoZG Profile sensor controller, PNP, 24 VDC, Includes Smart Monitor ZG Software. - OMRON - ZG2-WDC4

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or