MS2800S-EB-030-1000 247955 OMRON Safety light curtain, Basic, category 2, hand protection (30mm), 1000mm hei.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

MS2800S-EB-030-1000 247955 OMRON Safety light curtain, Basic, category 2, hand protection (30mm), 1000mm hei..

MS2800S-EB-030-1000

247955

OMRON

Available Ship on today

Safety light curtain, Basic, category 2, hand protection (30mm), 1000mm height, DC, 20m scan distance

More details


Discontinued or under quotations

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



MS4800/2800Safety sensors
Category 4 / 2 safety light curtain
The MS4800 and MS2800 family of safety light curtain provides simplicity in mounting, configuring, daily use and maintenanceby providing a:
• Sensing distance up to 20m for 30mm resolution and 7 m for 14mm resolution
•LED bar for easy alignment and diagnosis
• DIP-switch setupfor blanking,mutingand optical coding
• Category 4 / 2 sensor complying with EN 61496-1
• All-in-one M12 connection and mountingconcept with robust housing
• Multicascadable up to 3 sets
Ordering information
MS2800 Safety Category 2
Connection features Standard MasterSlave
Standard
Standalone operation
Master
Series connection, muting
Slave
Series connection only
MS2800S-MS2800FS-MS2800F-
Function SetBasic Advanced Basic Advanced
Basic
Interlock, restart, EDM,
2 optical channels, integrated alignment tool
Advanced
Muting, blanking (fixed/float- ing)
MS2800S-EB- MS2800S-EA- MS2800FS-EB- MS2800FS-EA- MS2800F-E-
Resolution 14 mm 30 mm 14 mm 30 mm 14 mm 30 mm 14 mm 30 mm 14 mm 30 mm
14 mm finger protectionMS2800S-EB-
MS2800S-EB-
MS2800S-EA-
MS2800S-EA-
MS2800FS-EB-MS2800FS-EB-MS2800FS-EA-MS2800FS-EA-
MS2800F-E-
MS2800F-E-
30 mm hand protection
Length
240 mm … 2120 mm in
40 mm increments
014-
280 … 1800
030-
280 … 2120
014-
280 … 1800
030-
280 … 2120
014-
280 … 1800
030-
280 … 2120
014-
280 … 1800
030-
280 … 2120
014-
240 … 1280
030-
280 … 2120
MS4800 Safety Category 4
Connection features Standard MasterSlave
Standard
Standalone operation
Master
Series connection, muting
Slave
Series connection only
MS4800S-MS4800FS-MS4800F-
Function SetBasic Advanced Basic Advanced
Basic
Interlock, restart, EDM,
2 optical channels, integrated alignment tool
Advanced Mut- ing, blanking (fixed/floating)
MS4800S-EB- MS4800S-EA- MS4800FS-EB- MS4800FS-EA- MS4800F-E-
Resolution 14mm30mm 14mm 30mm14mm 30mm14mm 30mm14mm 30mm
14 mm finger protectionMS4800S-EB-
MS4800S-EB-
MS4800S-EA-
MS4800S-EA-
MS4800FS-EB-MS4800FS-EB-MS4800FS-EA-MS4800FS-EA-
MS4800F-E-
MS4800F-E-
30 mm hand protection
Length
240 mm … 2120 mm in
40 mm increments
014-
280 ... 1800
030-
280 ... 2120
014-
280 ... 1800
030-
280 ... 2120
014-
280 ... 1800
030-
280 ... 2120
014-
280 ... 1800
030-
280 ... 2120
014-
240 ... 1280
030-
280 ... 2120
ExamplesMS2800S-EB-030-1000
Standalone operation
Basic functionset
30 mm resolution
1000 mm protective height
MS4800FS-EA-014-1200
Series connection model
Advanced function set
14 mm resolution
1200 mm protective height
MS4800F-E-014-600
Slave operation
14 mm resolution
600 mm protective height
480
MS4800/2800Safety sensors
Specifications
ModelMS4800_ -E_ -_ _ _ -_ _ _ _MS2800_ -E_ -_ _ _ -____ Sensor typeType 4Type2
Normal operating range
Reduced range (DIP-switch 6)
14 mm resolution: 0.3 - 7 m, 30 mm resolution: 0.3 - 20 m
14 mm resolution: 0.3 - 3 m, 30 mm resolution: 0.3 - 8 m
Beam pitch 14 mm resolution: 10 mm 30 mm resolution: 20 mm
Protective height 14 mm resolution: 280 - 1800 mm 30 mm resolution: 240 - 2120 mm
Detection capability14 mm resolution: 14 mm non-transparent 30 mm resolution: 30 mm non-transparent
Effective aperture angle (EAA) Within ±2,5°Within ±5,0°
for the emitter and receiver at a detection distance of at least 3m according to IEC61496-2
Light source Infrared LED's (880 nm), Power dissipation:180 mW, Class 1 per EN60825-1
Supply voltage (Vs)24 VDC ±20%, according EN/IEC60204, able to cover a drop of voltage of at least 20 msec OSSDTwo safety related PNP transistor output, load current 625 mA max.*1, short circuit protection Auxiliary output (non safety output)One PNP output sourcing 100mA @ 24VDC. This output follows the OSSD's
Output operation mode OSSD output: Light-ON
Test functionsSelf-test (after power ON and during operation)
Safety-related functionsAll versions: Auto reset/interlock with manual reset, EDM (external device monitoring) advanced versions only: fixed blanking, floating blanking, muting
Response time ON to OFF: 14 to 59 ms
Ambient light intensityIncandescent lamp: 3000 lx max. (light intensity on the receiver surface)
Ambient temperature Operating: -10°C to +55°C, storage: -25°C to +70°C (without icing or condensation)
Degree of protectionIP65 (IEC60529)
Connection method Flexible cable with M 12 connection: receiver: 8 pins, transmitter: 5 pins
MaterialsCase: Polyurethane powder painted aluminum, cap: polycarbonate, front window: acrylic, mounting brackets: cold rolled steel
Size (cross section) 39 x 50 mm
Receiver indicator lightsIndividual Beam Indicator (IBI), interlock, blanking activ, RUN and STOP state, error codes
Transmitter indicator lights ON, OFF, failure
AOPD (ESPE) Type4 acc. IEC 61496-1Type2 acc. IEC 61496-1
Suitable for safety control systemsCat. 4 acc. EN954-1, PLe acc. EN ISO 13849-1 Cat. 2 acc. EN954-1,PLc acc. EN ISO 13849-1
Safety Integrity Level SIL 3 according IEC 61508
PFH 5,9 x 10-8
*1Up to 12 m we recommend to use the F39-JMR cables,to use longer cables and a current of 625 mA the F39-JMR cables are necessary.
Connection example
Using a manual restart and an external device monitoring
Power supply
+24VDC GND
Fuse
Protective earth
*1
MTS requires a NC contact.If MTS is not used, please connect MTS and MTS Ret. Directly.
K2
K1 K1 *2
*2
The K1 andK2 coils mustbe suppressed. Please refer to the documentation of the relays or contactors for further reference.
EarthGND +24V DC
MTS Ret.
*1
MTSEarth GND+24V DC
K2*2
EDM Start Aux.OSSD1OSSD2
K1 andK2 forciblyguided relay’s expected
MS4800/MS2800
Transmitter
MS4800/MS2800
Receiver
481

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.