OS32C-CBL-10M 349179 OMRON Security Product, Cable OS32C ES power supply 10m View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

OS32C-CBL-10M 349179 OMRON Security Product, Cable OS32C ES power supply 10m

OS32C-CBL-10M

349179

OMRON

Available

Ship on today

Security Product, Cable OS32C ES power supply 10m

More details


Safety

Safety. Safety sensors - Safety laser scanner - OMRON

Safety. Safety sensors - Safety laser scanner - OS32C - OMRON

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



OS32C Safety sensors
OS32C Safety laser scanner
• Type 3 safety laser scanner complies with IEC61496-1/-3
• 70 sets of safety zone and warning zone combinations are available, supporting complicated changes in working environments
• A safety radius up to 4 m and warning zone(s) radius up to 10 m can be set
• 8 Individual sector indicators and various LED indications allow the user to determine scanner status at a glance
• Reference boundary monitoring function prevents unauthorized changes in the scanner position
• Configurable minimum object resolution of 30, 40, 50 or 70 mm, for hand and arm detection applications
Ordering information
Description Max. operating range Order code
Description Remarks Order code
OS32C with back location cable entry 3 m OS32C-BP
4m OS32C-BP-4M
Configuration tool CD-ROM
OS supported:
included
OS32C with side location cable entry*1
OS32C with back location cable entry EtherNet/IP capable for status measure- ment data reporting
OS32C with side location cable entry*1
EtherNet/IP capable for status measure- ment data reporting
3m OS32C-SP1
4m OS32C-SP1-4M
3m OS32C-BP-DM
4m OS32C-BP-DM-4M
3m OS32C-SP1-DM
4m OS32C-SP1-DM-4M
Windows 2000, XP, Vista, Windows 7
*1 Each connector is located on the left as viewed from the back of the I/O block.
Specifications
Sensors
Sensor type Type 3 safety laser scanner
Safety category Category 3, performance level d (ISO13849-1: 2006)
Detection capability Configurable Non-transparent with a diameter of 30, 40, 50 or 70 mm (1.8% reflectivity or greater)
Monitoring zone Monitoring zone set count: (Safety zone + 2 warning zones) × 70 sets
Operating range Safety Zone: 4.0 m (min. obj. resolution of 70mm, only OS32C-_-4M types)
3.0 m (min. obj. resolution of 50 mm or 70 mm)
2.5 m (min. obj. resolution of 40 mm)
1.75 m (min. obj. resolution of 30 mm) Warning Zone: 10.0 m (15.0 m for OS32C-_-4M types)
Detection angle 270°
Response time Response time from ON to OFF: From 80 ms (2 scans) to 680 ms (up to 17 scans)*1
Response time from OFF to ON: Response time from ON to OFF + 100 ms to 60 s (configurable)
Line voltage 24 VDC +25%/–30% (ripple p-p 2.5 V max.)
Power consumption Normal operation: 5 W max., 4 W typical (without output load)*2
Standby mode: 3.75 W (without output load)
Safety output (OSSD) PNP transistor × 2, load current of 250mA max., residual voltage of 2 V max., load capacity of 2.2 μf max., leak current of 1 mA max.*2,*3,*4
Auxiliary output (Non-safety) NPN/PNP transistor × 1, load current of 100 mA max., residual voltage of 2 V max., leak current of 1 mA max.*3,*4,*5
Warning output (Non-safety) NPN/PNP transistor × 1, load current of 100 mA max., residual voltage of 2 V max., leak current of 1 mA max.*3,*4,*5
Output operation mode Auto start, start interlock, start/restart interlock
Input External Device Monitoring (EDM) ON: 0 V short (input current of 50 mA), OFF: Open Start ON: 0 V short (input current of 20 mA), OFF: Open Zone select ON: 24 V short (input current of 5 mA), OFF: Open Stand-by ON: 24 V short (input current of 5 mA), OFF: Open
Connection type Power cable: 18-pin mini-connector (pigtail) Communication cable: M12, 4-pin connector
Connection with PC Communication: EtherNet/IP
Indicators RUN indicator: Green, STOP indicator: Red, Interlock indicator: Yellow, Warning output indicator: Orange, Status/diagnostic display: 2 × 7-segment LEDs, Intrusion indicators: Red LED × 8
Enclosure rating IP65 (IEC60529)
Dimensions (W × H × D) 133.0 × 104.5 × 142.7 mm (except cable)
Weight (Main Unit only) 1.3 kg
Approvals Certified by: TÜV Rheinland, UL
Major standards: IEC61496-1/-3 (Type 3), IEC61508 (SIL2), ISO13849-1:2008 (Category 3, performance level d), UL508, UL1998
*1 Pollution Tolerance will add 6 ms to each scan time.
*2 Rated current of OS32C is 1.025 A max. (OS32C 210 mA + OSSD A load + OSSD B load + auxiliary output load + warning output load + functional Inputs). Where functional inputs are: EDM input ... 50 mA, Start input ... 20 mA, Standby input ... 5 mA, Zone X input ... 5 mA × 8 (eight zone set select inputs).
*3 Output voltage is input voltage – 2.0 VDC.
*4 Total consumption current of 2 OSSDs, auxiliary output, and warning output must not exceed 700 mA.
*5 Output polarity (NPN/PNP) is configurable via the configuration tool.
489
OS32C Safety sensors
Accessories (sold separately)
Power cable
Appearance Description Remarks Order code
Cable length: 3 m One cable is required per sensor OS32C-CBL-03M Cable length: 10 m OS32C-CBL-10M Cable length: 20 m OS32C-CBL-20M
Cable length: 30 m OS32C-CBL-30M
Ethernet cable
Appearance Description Remarks Order code
Cable length: 2 m Required for configuration and monitoring OS32C-ECBL-02M Cable length: 5 m OS32C-ECBL-05M
Cable length: 15 m OS32C-ECBL-15M
Note: An ethernet cable with an M12, 4-pin connector is required.
Mounting brackets
Appearance Description Remarks Order code
Bottom/side mounting bracket Bottom/side mounting bracket × 1, unit mounting screws × 4 sets
OS32C-BKT1
XY axis rotation mounting bracket XY axis rotation mounting bracket × 1, unit mounting screws × 6 sets,
bracket mounting screws × 1 set
(must be used with OS32C-BKT1)
OS32C-BKT2
Simple mounting bracket Simple mounting brackets × 2, unit mounting screws × 4 sets*1
OS32C-BKT3
Protective cover for window OS32C-BKT4
Mounting stand When using a mounting stand, use an OS32C
with side location cable entry (OS32C-SP1).
The OS32C with back location cable entry (OS32C-BP)
cannot be mounted.
Use with mounting brackets (OS32C-BKT1 and OS32C-BKT2).
OS32C-MT
Hardware kit for mounting stand Mounting screws × 3 sets
Use this when mounting a bracket to the mounting stand.
OS32C-HDT
*1 There are eight OS32C mounting screws: four screws for singular use, and four screws for protective cover for window.
490
OS32C Safety sensors
Miscellaneous
Appearance Description Remarks Order code
Scan window Spare for replacement OS32C-WIN-KT
Sensor block without I/O block
Max. operating range: 3 m
Spare for replacement OS32C-SN
Sensor block without I/O block
Max. operating range: 4 m
OS32C-SN-4M
Sensor block without I/O block for EtherNet/IP Max. operating range: 3 m
Spare replacement for EtherNet/IP OS32C-SN-DM
Sensor block without I/O block for EtherNet/IP Max. operating range: 4 m
OS32C-SN-DM-4M
I/O block With cable access from the back
Spare for replacement OS32C-CBBP
With cable access from the left side
Spare for replacement OS32C-CBSP1
Window cleaning kit, anti-static cleaner Accessory WIN-CLN-KT
Connection
Basic connection with single OS32C unit
Category 3, performance level d (ISO13849-1)
Functional earth (Green)
24 VDC (White)
0 VDC (Brown)
Standby input (Violet)
Zone select 1 (Orange/White) Zone select 2 (Orange/Black) Zone select 3 (Gray)
Zone select 4 (Pink)
Zone select 5 (White/Black) Zone select 6 (Tan)
Zone select 7 (Orange)
Zone select 8 (Blue/White) Start (Black)
Auxiliary output (Blue)
Warning output (Red/Black) EDM (Brown/White)
Safety output B (Yellow) Safety output A (Red)
PE
0V
S3
*4 S2
*4 S2
*4 S2
*4 S2
*4 S2
*4 S2
*4 S2
*4 S2
*3 S1
*2 ED1 ED2
ED1
*1
ED2
*1
E1
+24V
ED1
ED2
M1
S1 : Start input
S2 : Zone select switch
S3 : Standby switch
ED1, ED2: Forced guided relay
M1 : 3-Phase motor
E1 : 24 VDC Power
OS32C configuration
– External Device Monitoring enabled
– Start/restart interlock
*1. External devices (ED1, ED2) are forced guide relays. (G7Z, G7SA, G7S, etc)
*2. If the External Device Monitoring is not used, connect brown/white wires to 0 V, and then turn OFF the
External Device Monitoring with the configuration software.
*3. Use NC-contact for a start input.
*4. For zone select switch setting, refer to OS32C Series user's manual.
Note: This wiring example is for category 3.
491

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoSafety laser scanner power and I/O cable, 10m - OMRON - OS32C-CBL-10M - 349179English263 Kbytespdf1-mostradoSafety laser scanner power and I/O cable, 10m - OMRON - OS32C-CBL-10M - 349179
pdf2-mostradoSafety laser scanner power and I/O cable, 10m - OMRON - OS32C-CBL-10M - 349179English632 Kbytespdf1-mostradoSafety laser scanner power and I/O cable, 10m - OMRON - OS32C-CBL-10M - 349179

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or