K8DS-PA1 387485 OMRON Monitoring Relays, Three Phase Asymmetry Sequence + Lost + 17.5mm phase 200-240AC View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

K8DS-PA1 387485 OMRON Monitoring Relays, Three Phase Asymmetry Sequence + Lost + 17.5mm phase 200-240AC

K8DS-PA1

387485

OMRON

Available

Ship on today

Monitoring Relays, Three Phase Asymmetry Sequence + Lost + 17.5mm phase 200-240AC

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



K8DS-PA 3-phase control
3-Phase voltage, phase sequence, loss and asymmetry
The K8DS-PA is the simplified 3-phase monitoring relay, 3-wire circuits with one unit. It can monitor voltage asymmetry with 3-phase sequence and loss at the same time.
• Greater resistance to inverter noise
•OneSPDT output relay, 5 A at 250 VAC (resistive load)
• World-wide power specifications supported by one unit (Set with a rotary switch)
• Relay statuscan be monitoredusing LED indicator
Ordering information
Rated input Order code
3-phase 3-wire mode 200, 220, 230, 240 VACK8DS-PA1
3-phase 3-wire mode 380, 400, 415, 480 VACK8DS-PA2
Specifications
Ambient operating temperature –20 to 60°C (with no condensation or icing) Storage temperature –25 to 65°C (with no condensation or icing) Altitude 2,000 m max.
Input frequency50/60 Hz (AC power supply)
Output relays
(1 × SPDT, normally closed operation)
Resistive load5 A at 250VAC or at 30 VDC Maximum contact voltage250VAC or 30 VDC Maximum contact current 5 A
Maximum switching capacity 1,250 VA, 150 W
Mechanical life10,000,000 operations
Electrical life 50,000 operations at 5 A, 250VAC or 30 VDC
Degree of protection Terminal section: IP20
Case material PC UL94 V-0
WeightApprox. 65 g
Rated input voltageK8DS-PA1 3-phase,3-wire mode: 200, 220, 230, 240 VAC
K8DS-PA2 3-phase, 3-wire mode: 380, 400, 415, 480 VAC
Asymmetry operation
(ASY.)
Operating value setting rangeAsymmetry rate: 2% to 22%
Operating value100% operation at set value
Asymmetry operating value = rated input voltage x asymmetry set value [%]
The asymmetry operation will function when the difference between the highest and lowest voltage phases equals or exceeds the asymmetry operating value
Reset (HYS.)Hysteresis 5% of operating value (fixed)
Resetting methodAutomatic reset
Operating time (T) Asymmetry0.1 to 30 s Phase-sequence0.1 s ±0.5 s Phase-loss 0.1 s max.
Power ON lock (LOCK) 1 s ±0.5 s
Overload capacity Continuous input: 500 V
Repeat accuracy Operating value±0.5% full scale (at 25°C and an ambient humidity of 65% at the rated power supply voltage, 50/60 Hz sine wave input)
Operating time±50 ms (at 25°C and 65% humidity, rated power supply voltage) IndicatorsPower (PWR): Green,Relay output (RY): Yellow, Alarm outputs (ALM): Red Applicable standards Conforming standards EN 60947-5-1
Installation environment (pollution level 2, installation category III)
EMC EN 60947-5-1
Safety standardsUL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA: C22.2No. 14, CCC: GB14048.5
Size (H × W × D)80 × 17.5 × 74 mm
650

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoOMRON - K8DS-PA1 - 387485English128 Kbytespdf1-mostradoOMRON - K8DS-PA1 - 387485
pdf2-mostradoOMRON - K8DS-PA1 - 387485English1 Mbytespdf1-mostradoOMRON - K8DS-PA1 - 387485

Reviews (0)