K8AK-AW2 100-240VAC 378166 OMRON Monitoring relays, Max and Min current Single phase 100-240VAC 0,1-8A 2 SPDT View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

K8AK-AW2 100-240VAC 378166 OMRON Monitoring relays, Max and Min current Single phase 100-240VAC 0,1-8A 2 SPDT

K8AK-AW2 100-240VAC

378166

OMRON

Available

Ship on today

Monitoring relays, Max and Min current Single phase 100-240VAC 0,1-8A 2 SPDT

More details


* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



K8AK-AW 1-phase control
Single-phase current relay, window type
These single-phase current relays monitor over- and undercurrents. Manual resetting and automatic resetting are supported by one relay. The start-up lock and operating
time can be set separately. The relay warning status is easily monitored with the LED
indicator.
• Single-phase current window relay
• In 22.5 mm wide industrial housing
• Under and over control
• Supply voltages: 24 VAC/DC, 100 to 240 VAC
• Easy wiring with ferrules
Ordering information
Measuring current Supply voltage Order code
2 to 20 mA AC/DC,
10 to 100 mA AC/DC,
50 to 500 mA AC/DC
0.1 to 1 A AC/DC,
0.5 to 5 A AC/DC
10 to 100 A AC,
20 to 200 A AC
24 VAC/DC K8AK-AW1 24 VAC/DC
100 to 240 VAC K8AK-AW1 100-240 VAC
24 VAC/DC K8AK-AW2 24 VAC/DC
100 to 240 VAC K8AK-AW2 100-240 VAC
24 VAC/DC K8AK-AW3 24 VAC/DC
100 to 240 VAC K8AK-AW3 100-240 VAC
Accessories
Current transformer Input range Applicable relay Order code
10 to 100 A AC, 20 to 200 A AC K8AK-AW3 K8AC-CT200L
Note: The K8AK-AW3 is designed to be used in combination with the K8AC-CT200L (direct input not possible)
Specifications
Ambient operating temperature –20 to 60°C (with no condensation or icing) Storage temperature –25 to 65°C (with no condensation or icing) Operating voltage range 85% to 110% of rated operating voltage Rated power supply frequency 50/60 Hz±5 Hz (AC power supply)
Output relays
(1 × SPDT, normally closed operation)
Resistive load 5 A at 250 VAC or at 30 VDC Maximum contact voltage 250 VAC or 30 VDC Maximum contact current 5 A
Maximum switching capacity 1,250 VA, 150 W
Mechanical life 10,000,000 operations
Electrical life 50,000 operations at 5 A, 250 VAC or 30 VDC
Degree of protection Terminal section: IP20
Case material PC and ABS
Weight Approx. 150 g
Operating power Isolated power supply 2.0 VA/1.1 W max. at 24 VAC/DC, 4.6 VA max. at 100 to 240 VAC
Operate (SV) Operating value setting range 10% to 100% of maximum measuring current
Operating value 100% operation at set value
Reset (HYS.) Hysteresis 5% of operating value (fixed)
Resetting method Manual reset/automatic reset (switchable)
Manual reset: Turn OFF operating power for 1 s or longer
Operating time (T) 0.1 to 30 s
Operating power ON lock (LOCK) 0 to 30 s (The startup lock timer starts when the input has reached approximately 30% or more of the set value.) Note: Enabled only for overcurrent operation
Repeat error Operating value ±0.5% full scale (at 25°C and 65% humidity, rated power supply voltage, DC or 50/60 Hz sine wave input)
Operating time ±50 ms (at 25°C and 65% humidity, rated power supply voltage)
Input frequency range
K8AK-AW1/-AW2 DC input or AC input (45 to 65 Hz)
K8AK-AW3 AC input (45 to 65 Hz)
Overload capacity K8AK-AW1/-AW2 Continuous input at 120% of maximum input, 1 s at 150%
K8AK-AW3 Continuous input at 120%, 30 s at 200%, and 1 s at 600% with an OMRON CT (K8AC-CT200L) Indicators Power (PWR): Green LED, relay output (RY): Yellow LED, alarm outputs (ALM): Red LED Applicable standards Conforming standards EN 60947-5-1
Installation environment (pollution level 2, installation category III)
EMC EN 60947-5-1
Safety standards UL 508 (Recognition), Korean Radio Waves Act (Act 10564), CSA and CCC
Size in mm (H × W × D) 90 × 22.5 × 100
642

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoOMRON - K8AK-AW2 100-240VAC - 378166English144 Kbytespdf1-mostradoOMRON - K8AK-AW2 100-240VAC - 378166
pdf2-mostradoOMRON - K8AK-AW2 100-240VAC - 378166English1 Mbytespdf1-mostradoOMRON - K8AK-AW2 100-240VAC - 378166
pdf3-mostradoOMRON - K8AK-AW2 100-240VAC - 378166English2 Mbytespdf1-mostradoOMRON - K8AK-AW2 100-240VAC - 378166

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or