J7MN-3P-E63 234278 OMRON Low Voltage Switchgear, 0.4 to 0.63 A / 0.18kW Basculante View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

J7MN-3P-E63 234278 OMRON Low Voltage Switchgear, 0.4 to 0.63 A / 0.18kW Basculante

J7MN-3P-E63

234278

OMRON

Available

Ship on today

Low Voltage Switchgear, 0.4 to 0.63 A / 0.18kW Basculante

More details


Motor Circuit Protectors Protection Breaker

Low voltage switchgear - Motor protection circuit breakers - OMRON

Low voltage switchgear - Motor protection circuit breakers - J7MN - OMRON

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

QuantityPrice
1+$36.27
7+$32.94
13+$32.23
19+$31.86
25+$31.62
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



J7MN Motor protection circuit breakers
J7MN motor protection circuit breakers from 0.10 A to 100 A
J7MN starters protect motors against thermal overload and short circuit.
The J7MN can be equipped with additional auxiliary contacts, tripping indicator
(alarm), undervoltage release and/or shunt release. All models can be locked for safe maintenance.
• Rated operational currents of 32 A for the rocker type
• Rated operational currents of 32 A, 63 A and 100 A for the rotary types
• Switching capacity is 100 kA/415 V up-to 13 A and 50 kA/415 V up-to 100 A
• Electrical/mechanical link modules available up-to 11 kW motor protection units
• All components are finger proof
Ordering information
Rated
Suitable for motors
Current setting range Short-circuit breaking
Size in mm (H × W × D) Order code
current in A
3 ~ 400 V kW
Thermal
overload release A
Instantaneous
short-circuit release A
capacity at 3 ~ 400 V kA
0.16 – 0.10– 0.16 2.1 100 98 × 45 × 75 J7MN-3P-E16
0.25 0.06 0.16–0.25 3.3 100 J7MN-3P-E25
0.4 0.09 0.25–0.4 5.2 100 J7MN-3P-E4
0.63 0.18 0.4–0.63 8.2 100 J7MN-3P-E63
1 0.25 0.63–1 13 100 J7MN-3P-1
1.6 0.55 1–1.6 20.8 100 J7MN-3P-1E6
2.5 0.75 1.6–2.5 32.5 100 J7MN-3P-2E5
4 1.5 2.5–4 52 100 J7MN-3P-4
6 2.2 4–6 78 100 J7MN-3P-6
8 3 5–8 104 100 J7MN-3P-8
10 4 6–10 130 50 J7MN-3P-10
13 5.5 9–13 169 50 J7MN-3P-13
17 7.5 11–17 221 20 J7MN-3P-17
22 7.5 14–22 286 15 J7MN-3P-22
26 11 18–26 338 15 J7MN-3P-26
32 15 22–32 416 15 J7MN-3P-32
0.16 – 0.10–0.16 2.1 100 98 × 45 × 100 J7MN-3R-E16
0.25 0.06 0.16–0.25 3.3 100 J7MN-3R-E25
0.4 0.09 0.25–0.4 5.2 100 J7MN-3R-E4
0.63 0.18 0.4–0.63 8.2 100 J7MN-3R-E63
1 0.25 0.63–1 13 100 J7MN-3R-1
1.6 0.55 1–1.6 20.8 100 J7MN-3R-1E6
2.5 0.75 1.6–2.5 32.5 100 J7MN-3R-2E5
4 1.5 2.5–4 52 100 J7MN-3R-4
6 2.2 4–6 78 100 J7MN-3R-6
8 3 5–8 104 100 J7MN-3R-8
10 4 6–10 130 100 J7MN-3R-10
13 5.5 9–13 169 100 J7MN-3R-13
17 7.5 11–17 221 50 J7MN-3R-17
22 7.5 14–22 286 50 J7MN-3R-22
26 11 18–26 338 50 J7MN-3R-26
32 15 22–32 416 50 J7MN-3R-32
26 12.5 18–26 338 50 140 × 55 × 144 J7MN-6R-26
32 15 22–32 416 50 J7MN-6R-32
40 18.5 28–40 520 50 J7MN-6R-40
50 22 34–50 650 50 J7MN-6R-50
63 30 45–63 819 50 J7MN-6R-63
63 30 45–63 819 50 165 × 70 × 171 J7MN-9R-63
75 37 55–75 975 50 J7MN-9R-75
90 45 70–90 1170 50 J7MN-9R-90
100 – 80–100 1300 50 J7MN-9R-100
631
J7MN Motor protection circuit breakers
Accessories
Description Version For circuit breaker Order code
Transverse auxiliary contact block
Contact block 1 NO + 1 NC All J77MN-11F
2NO J77MN-20F
2NC J77MN-02F
Auxiliary contact block for left hand side mounting (max. 2 pc. per circuit breaker)
Contact block (9 mm) 1 NO + 1 NC All J77MN-11S
2NO J77MN-20S
2NC J77MN-02S
Signalling switch for left hand side mounting (max. 1 pc. per circuit breaker)
Signalling switch (18 mm) 1 NO + 1 NC any tripping condition J7MN-3P/-3R J77MN-TA-11S J7MN-6R/-9R J77MN-TB-11S
1 NO + 1 NC short circuit tripping condition All J77MN-T-11S
Undervoltage releases for right hand side mounting (max 1 pc. per circuit breaker)
AC 50 Hz AC 60 Hz
Trips the circuit breaker when the voltage is interrupted. Pre- vents the motor from being restarted accidentally when the voltage is restored, suitable for EMERGENCY STOP according to VDE 0113
24 V 28 V All J77MN-U-24
110–127 V 120 V J77MN-U-110
220–230 V 240–260 V J77MN-U-230
240 V 277 V J77MN-U-240
380–400 V 440–460 V J77MN-U-400
415–440 V 460–480 V J77MN-U-415
Shunt releases for right hand side mounting (max 1 pc. per circuit breaker)
AC 50 Hz AC 60 Hz
Trips the circuit breaker when the release coil is energized
Terminal block
24 V 28 V All J77MN-S-24
110–127 V 120 V J77MN-S-110
220–230 V 240–260 V J77MN-S-230
240 V 277 V J77MN-S-240
380–400 V 440–460 V J77MN-S-400
415–440 V 460–480 V J77MN-S-415
Terminal block Up to 600 V according to UL 489 not for transverse auxiliary contact block
J7MN-3R J77MN-TB32
J7MN-9R J77MN-TB100
Insulated 3-Phase Busbar System IP20
Description Connection type Version For Units (MPCB) Order code
3-phase busbars
modular spacing = 45 mm
Spade for 2 units J7MN-3P J7MN-3R J77MN-CPM-3-45-2S for 3 units J77MN-CPM-3-45-3S for 4 units J77MN-CPM-3-45-4S for 5 units J77MN-CPM-3-45-5S
Line side terminal 3-pole, connection from above
conductor cross-section solid or stranded 6–25 mm² with end sleeve 4–16 mm²
Spade acc. IEC/EN 60947-1, 60947-2,
60947-4-1 and VDE 0660
J7MN-3P J7MN-3R J77MN-BTC-63-SE
Line side terminal 3-pole, connection from above
conductor cross-section solid or stranded 6–25 mm² with end sleeve 4–16 mm²
Spade up to 600 V acc. UL 489 J7MN-3P J7MN-3R J77MN-BTC-63-SEV
Shrouds for unused terminals on busbar system Spade J7MN-3P J7MN-3R J77MN-TA-63S
632
J7MN Motor protection circuit breakers
Specifications
Type J7MN-3P J7MN-3R J7MN-6R J7MN-9R Number of poles 3 3 3 3
Max. rated current Inmax (= max. rated operational current Ie)
Permissible ambient temperature
A 32 32 63 100
Storage/transport –50 to 80°C
Operation –20 to 60°C
Rated operational voltage Ue V 690
Rated frequency Hz 50/60
Rated insulation voltage Ui V 690
Rated impulse withstand voltage Uimp
kV 6
Utilization category IEC 60 947-2 (circuit breaker) A
IEC 60 947-4-1 (motor starter) AC-3
Class According to IEC 60 947-4-1 10
Degree of protection According to IEC 60 529 IP20 IP20 IP20 IP20
Phase failure sensitivity According to IEC 60 947-4-1 Yes
Explosion protection According to EC Directive
94191EC
Yes
Isolator characteristics According to IEC 60 947-3 Yes
Main and EM. STOP switch characteristics
According to IEC 60 204-1 (VDE113)
Yes
Safe isolation between main and auxiliary circuits According to DIN VDE 0106
Part 101
Up to 400 V + 10% Yes
Up to 415 V + 5% Yes
Mechanical endurance Operating cycles 100,000 100,000 50,000 50,000
Electrical endurance 100,000 100,000 25,000 25,000
Max. operating frequency per 1/h 25 25 25 25
hour (motor starts)
633

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoMotor-protective circuit breaker, switch type, 3-pole, 0.4A-0.63A - OMRON - J7MN-3P-E63 - 234278English215 Kbytespdf1-mostradoMotor-protective circuit breaker, switch type, 3-pole, 0.4A-0.63A - OMRON - J7MN-3P-E63 - 234278
pdf2-mostradoMotor-protective circuit breaker, switch type, 3-pole, 0.4A-0.63A - OMRON - J7MN-3P-E63 - 234278English2 Mbytespdf1-mostradoMotor-protective circuit breaker, switch type, 3-pole, 0.4A-0.63A - OMRON - J7MN-3P-E63 - 234278

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or