G3PF-225B 24VDC G3PF0005M 242978 OMRON 25A 240VAC 1Screw Outlet View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

G3PF-225B 24VDC G3PF0005M 242978 OMRON 25A 240VAC 1Screw Outlet

G3PF-225B 24VDC

G3PF0005M

G3PF225BDC24

OMRON

Available Ship on today

25A 240VAC 1Salida Screws

25A 240VAC 1Screw Outlet

More details


Solid State Relays > G3PF

* Brand new product in its original packaging covered by the warranties and certifications provided by OMRON

Total price: $230.58
Unit price: $230.58

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Related products

More info



Features

“Intelligent” SSR with Built-in current transformer which enables Heater Burnout and SSR Shortcircuit Failure Detection.

The G3PF quickly detects heater burnout and SSR short-circuit failure, and information is provided to let you know which problem has occurred, which is ideal for applications where down time must be minimized.

  • Built-in Current Transformer (CT) helps reduce wiring steps.
  • Detects the burnout of any one of a group of heaters.
  • Detects the burnout of 3-phase heaters.
  • Detects SSR short-circuit failures.
  • Error detection level can be easily set with a switch.
  • Zero cross function.
  • Operation indicator.

Ordering information

Applicable output load1

Input terminals

Alarm output

Size in mm (H×W×D)

Order code

100 to 240 VAC

2 to 25 A

M3 terminals

1 output (Heater Burnout Detection,
SSR Short-circuit Failure Detection, Common)

100×45×110

G3PF-225B

2 to 35 A

100×55×130

G3PF-235B

200 to 480 VAC

2 to 25 A

100×45×110

G3PF-525B

2 to 35 A

100×55×130

G3PF-535B

100 to 240 VAC

2 to 25 A

Screwless clamp terminals (detachable)

2 outputs (Heater Burnout Detection,
SSR Short-circuit Failure Detection)

100×45×117

G3PF-225B-CTB

2 to 35 A

100×55×137

G3PF-235B-CTB

200 to 480 VAC

2 to 25 A

100×45×117

G3PF-525B-CTB

2 to 35 A

100×55×137

G3PF-535B-CTB

Specifications

Order code

G3PF-225B

G3PF-235B

G3PF-525B

G3PF-535

Rated load voltage

100 to 240 VAC (50/60 Hz)

200 to 480 VAC (50/60 Hz)

Operating voltage range

75 to 264 VAC, 50/60 Hz

180 to 528 VAC, 50/60 Hz

Applicable load current2

25 A (at 40°C)

35 A (at 40°C)

25 A (at 40°C)

35 A (at 40°C)

Minimum load current

2 A

Inrush current resistance

220 A (60 Hz, 1 cycle)

430 A (60 Hz, 1 cycle)

220 A (60 Hz, 1 cycle)

430 A (60 Hz, 1 cycle)

Operate time

1/2 of load power source cycle + 1 ms max.

Release time

1/2 of load power source cycle + 1 ms max.

Main circuit

Output ON voltage drop

1.6 V (RMS) max.

1.8 V (RMS) max.

Leakage current

10 mA max. (at 200 VAC)

20 mA max. (at 480 VAC)

Alarm output

Output ON voltage drop

1.5 V max.

Leakage current

1 mA max.

Isolation resistance

100 MΩ min. (at 500 VDC)

Dielectric strength

2,500 VAC, 50/60 Hz for 1 min.

Vibration resistance

Destruction: 10 to 55 to10 Hz, 0,35-mm single amplitude (0,7-mm double amplitude)

Shock resistance

Destruction: 294 m/s²

Ambient storage temperature

−30 to 70°C (with no icing or condensation)

Ambient operating temperature

−20 to 60°C (with no icing or condensation)

Ambient operating humidity

45% to 85%

Weight

Approx. 400 g

Approx. 630 g

Approx. 400 g

Approx. 630 g


1.The load current depends on the ambient temperature. Refer to datasheet for details.
2.The load current depends on the ambient temperature.

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.