F39-LJ3 189910 OMRON Security Product, mounting bracket F3SJ-A intermediate side View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

F39-LJ3 189910 OMRON Security Product, mounting bracket F3SJ-A intermediate side

F39-LJ3

189910

OMRON

Available

Ship on today

Security Product, mounting bracket F3SJ-A intermediate side

More details


Safety

Safety. Safety limit switches - Multi-beam safety sensor - OMRON

Safety. Safety limit switches - Multi-beam safety sensor - F3S-TGR-CL (Accessories) - OMRON

* Brand new produt in its original packing covered by the warranties and certifications provided by OMRON

QuantityPrice
1+$52.72
6+$48.32
11+$47.29
16+$46.75
22+$46.36
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



F3SJ-A Safety sensors
Advanced type for complex safety solutions
The F3SJ-A-family is a type 4 safety light curtain with a optical resolution of 14 mm
and 30 mm. An operating range of up to 9 m and protective heights up to 2,495 mm are provided with no dead zone.
• Detection heigth = sensor height
• Muting and blanking function available
• Series connection up to 4 Sets
• LED bar for easy alignment and diagnosis
• Type 4 sensor complying with EN 61496-1 and up to
PLe according EN ISO 13849-1
Ordering information
Application Detection capability Beam gap Operating range Protective height (mm) Order code
Finger protection Dia. 14 mm 9 mm 0.2 to 9 m 245 to 1,631 F3SJ-A P14
Hand/arm protection Dia. 30 mm 25 mm 0.2 to 9 m 245 to 1,620 F3SJ-A P30
0.2 to 7 m 1,745 to 2,495
Safety light curtain model list
F3SJ-A14 series (9 mm gap), F3SJ-A14 TS series (9 mm gap) F3SJ-A30 series (25 mm gap)
Number of beams Protective height (mm)*1
Order code
Number of beams Protective height (mm)*1
Order code
26 245 F3SJ-A0245P14
28 263 F3SJ-A0263P14
34 317 F3SJ-A0317P14
42 389 F3SJ-A0389P14
50 461 F3SJ-A0461P14
60 551 F3SJ-A0551P14
68 623 F3SJ-A0623P14
76 695 F3SJ-A0695P14
80 731 F3SJ-A0731P14
88 803 F3SJ-A0803P14
96 875 F3SJ-A0875P14
108 983 F3SJ-A0983P14
116 1,055 F3SJ-A1055P14
124 1,127 F3SJ-A1127P14
132 1,199 F3SJ-A1199P14
140 1,271 F3SJ-A1271P14
*1 Protective height (mm) = Total sensor length
10 245 F3SJ-A0245P30
12 295 F3SJ-A0295P30
16 395 F3SJ-A0395P30
19 470 F3SJ-A0470P30
21 520 F3SJ-A0520P30
22 545 F3SJ-A0545P30
23 570 F3SJ-A0570P30
25 620 F3SJ-A0620P30
29 720 F3SJ-A0720P30
32 795 F3SJ-A0795P30
35 870 F3SJ-A0870P30
37 920 F3SJ-A0920P30
38 945 F3SJ-A0945P30
41 1,020 F3SJ-A1020P30
44 1,095 F3SJ-A1095P30
45 1,120 F3SJ-A1120P30
48 1,195 F3SJ-A1195P30
51 1,270 F3SJ-A1270P30
56 1,395 F3SJ-A1395P30
65 1,620 F3SJ-A1620P30
70 1,745 F3SJ-A1745P30
75 1,870 F3SJ-A1870P30
80 1,995 F3SJ-A1995P30
90 2,245 F3SJ-A2245P30
95 2,370 F3SJ-A2370P30
100 2,495 F3SJ-A2495P30
*1 Protective height (mm) = Total sensor length
474
F3SJ-A Safety sensors
Accessories (sold separately)
Single-end connector cable (2 cables per set, for emitter and receiver)
For wiring with safety circuit such as single safety relay, safety relay unit, and safety controller.
Appearance Cable length Specifications Order code
0.5 m M12 connector (8-pin) F39-JCR5A
3 m F39-JC3A
7 m F39-JC7A
10 m F39-JC10A
15 m F39-JC15A
20 m F39-JC20A
Setting Tools
Appearance Type Remarks Order code
“SD Manager”
Setting support software for the F3SJ
Accessories:
SD Manager CD-ROM (1),
F39-CN1 branch connector (1), Connector cap (1),
2-m Dedicated cable (1),
0.3-m Dedicated cable with plug (1), Instruction manual
F39-GWUM
Sensor Mounting Brackets (Sold separately)
Appearance Specifications Application Remarks Order code
Standard mounting bracket
(for top/bottom)
(provided with the F3SJ) 2 for an emitter,
2 for a receiver, total of 4 per set
F39-LJ1
Flat side mounting bracket Use these small-sized brackets when perform- 2 for an emitter,
F39-LJ2
ing side mounting with standard mounting
2 for a receiver,
brackets, so that they do not protrude from the total of 4 per set detection surface.
Free-location mounting bracket
(also used as standard inter- mediate bracket)
Use these brackets for mounting on any place without using standard bracket.
Two brackets per set
F39-LJ3
F3SN Intermediate bracket
Replacement spacers
When replacing the F3SN with the F3SJ, the mounting hole pitches in the Intermediate Brackets are not the same. This Spacer is placed between the mounting holes to mount the F3SJ.
1 set with
2 pieces
F39-LJ3-SN
Top/bottom bracket B (mounting hole pitch 19 mm)
Mounting bracket used when replacing exist- ing area sensors (other than F3SN or F3WN) with the F3SJ.
For front mounting.
Suitable for mounting hole pitch of 18 to 20 mm.
2 for an emitter,
2 for a receiver, total of 4 per set
F39-LJ4
Bracket for replacing
Mounting bracket used when an F3SN with
2 for an emitter,
F39-LJ5
short-length F3SN
protective height of 300 mm or less is replaced 2 for a receiver,
by an F3SJ.
total of 4 per set
Space-saving mounting bracket
Use these brackets to mount facing inward. Length is 12 mm shorter than the standard F39-LJ1 bracket.
2 for an emitter,
2 for a receiver, total of 4 per set
F39-LJ8
Top/bottom bracket C (mounting hole pitch
13 mm)
Mounting bracket used when replacing exist- ing area sensors having a mounting pitch of
13 mm with the F3SJ.
2 for an emitter,
2 for a receiver, total of 4 per set
F39-LJ11
475
F3SJ-A Safety sensors
Laser pointer
Appearance Output Order code
Laser pointer for F3SJ F39-PTJ
Specifications
F3SJ-A P14/P30
Model F3SJ-A
P14 F3SJ-A_
P30
Sensor type Type 4 safety light curtain
Version Ver. 2
Setting tool connection Connectable
Safety category Safety purpose of category 4, 3, 2, 1, or B
Detection capability Opaque objects 14 mm in diameter Opaque objects 30 mm in diameter
Beam gap (P) 9 mm 25 mm
Number of beams (n) 26 to 180 10 to 100
Protective height (PH) 245 to 1,631 mm 245 to 2,495 mm
Lens diameter Diameter 5 mm
Operating range 0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm min.) (Depending on the setting tool, the detection distance can be shortened to 0.5 m.)
Response time
(under stable light incident condition)
ON to OFF 1 set, 0245 to 983: 11 ms to 17.5 ms max.
1,055 or higher: 20 ms to 25 ms max.
OFF to ON 1 set, 0245 to 983: 44 ms to 70 ms max.
1,055 or higher: 80 ms to 100 ms max.
1 set: 10 ms to 17.5 ms max.
1 set: 40 ms to 70 ms max.
Startup waiting time 2 s max. (2.2 s max. for series connection)
Power supply voltage (Vs) 24 VDC±20% (ripple p-p10% max.)
Current consumption
(no load)
Emitter To 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA max.,
151 to 180 beams: 153 mA max., 201 to 234 beams: 165 mA max.
Receiver To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,
151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max.
Light source (emitted wavelength) Infrared LED (870 nm)
Effective aperture angle (EAA) Based on IEC 61496-2.Within±2.5° for both emitter and receiver when the detection distance is 3 m or over
Safety outputs (OSSD) Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), allowable capacity load 2.2 F, leak current 1 mA max.
(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
Auxiliary output 1 (Non-safety output)
Auxiliary output 2
(Non-safety output. Function for Basic System.)
External indicator output
(Non-safety output)
One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max.
One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension), leak current 1 mA max.
Available indicators
Incandescent lamp: 24 VDC, 3 to 7 W
LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.
(To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.)
Output operation mode Receiver Safety output 1, 2: ON when receiving light
Auxiliary output 1: Inverse of safety output signals (Operation mode can be changed with the setting tool.)
External indicator output 1: Inverse of safety output signals for a basic system (Operation mode can be changed with the setting tool.), ON when muting/override for a muting system (Operation mode can be changed with the setting tool.)
Emitter Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached (Operation mode can be changed with the setting tool.)
External indicator output 2: ON when lock-out for a basic system (Operation mode can be changed with the setting tool.) ON when muting/override for a muting system (Operation mode can be changed with the setting tool.)
476
F3SJ-A Safety sensors
Model F3SJ-A
P14 F3SJ-A
_P30
Input voltage Test input, interlock selection input, reset input, and muting input are all
ON voltage: 9 to 24 V (Vs) (sink current: 3 mA max.), OFF voltage: 0 to 1.5 V, or open
External device monitoring input
ON voltage: 9 to 24 V (Vs) (sink current: 5 mA max.), OFF voltage: 0 to 1.5 V, or open
Indicator Emitter Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensity
Error mode indicators (red LED × 3): Blink to indicate error details
Power indicator (green LED × 1): ON while power is on
Interlock indicator (yellow LED × 1): ON while under interlock, blinks at lockout.
External device monitoring indicator (muting input 1 indicator), Blanking/test indicator (muting input 2 indicator) (green LED × 2): ON/flash according to function
Receiver Light intensity level indicators (green LED × 2, orange LED × 3): ON based on the light intensity
Error mode indicators (red LED × 3): Blink to indicate error details
OFF output indicator (red LED × 1): ON when safety output is OFF, blinks at lockout. ON output indicator (green LED × 1): ON while safety output is ON
Muting error indicator, Blanking/test indicator (green LED × 2): ON/flash according to function
Mutual interference prevention function Interference light prevention algorithm, sensing distance change function
Series connection Time division emission by series connection
Number of connections: up to 4 sets (F3SJ-A only) F3SJ-E, F3SJ-B and F3SJ-TS cannot be connected. Total number of beams: up to 400 beams
Maximum cable length for 2 sets: no longer than 15 m
Test function Self test (at power-ON and at power distribution) External test (emission stop function by test input)
Safety-related functions Start interlock, restart interlock (Must be set with a setting tool when the muting function is used.) External device monitor
Muting (Lamp burnout detection, override function included. F39-CN6 key cap for muting is required.) Fixed blanking (must be set by a setting tool)
Floating blanking (must be set by a setting tool)
Connection method Connector method (M12, 8-pin)
Protection circuit Output short-circuit protection, and power supply reverse polarity protection
Ambient temperature Operating: –10 to 55°C (no icing), Storage: –30 to 70°C
Ambient humidity Operating: 35% to 85% (no condensation), Storage: 35% to 95%
Operating ambient light intensity Incandescent lamp: receiving-surface light intensity of 3,000 lx max., Sunlight: receiving-surface light intensity of 10,000 lx max.
Insulation resistance 20 M min. (at 500 VDC) Withstand voltage 1,000 VAC 50/60 Hz, 1 min Degree of protection IP65 (IEC 60529)
Vibration resistance Malfunction: 10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps in X, Y, and Z directions
Shock resistance Malfunction: 100 m/s2, 1,000 times each in X, Y, and Z directions
Material Casing (including metal parts on both ends): Aluminum, zinc die-cast
Cap: ABS resin, Optical cover: PMMA resin (acrylic), Cable: Oil resistant PVC
Weight (packaged) Calculate using the following expressions:
(1) For F3SJ-A _14, weight (g) = (protective height) x 1.7 + 
(2) F3SJ-A _30, weight (g) = (protective height) x 1.5 + 
The values for  are as follows:
Protected height 245 to 596 mm: = 1,100 protected height 1,660 to 2,180 mm: = 2,400
Protected height 600 to 1,130 mm: = 1,500 protected height 2,195 to 2,500 mm: = 2,600
Protected height 1,136 to 1,658 mm: = 2,000
Accessories Test rod (*1), instruction manual, standard mounting bracket (F39-LJ1 bracket for top/bottom mounting), mounting brackets
(intermediate) (*2), error mode label, User's Manual (CD-ROM)
*1. The F3SJ-A@@@@55 is not included.
*2. Number of intermediate brackets depends on protective height of F3SJ.
For protective height from 600 to 1,130 mm: 1 set for each of the emitter and receiver is included
For protective height from 1,136 to 1,658 mm: 2 sets for each of the emitter and receiver are included For protective height from 1,660 to 2,180 mm: 3 sets for each of the emitter and receiver are included For protective height from 2,195 to 2,500 mm: 4 sets for each of the emitter and receiver are included
Applicable standards IEC 61496-1, EN 61496-1 UL 61496-1, Type 4 ESPE (Electro-Sensitive Protective Equipment)
IEC 61496-2, CLC/TS 61496-2, UL 61496-2, Type 4 AOPD (Active Opto-electronic Protective Devices) IEC 61508-1 to -3, EN 61508-1 to -3 SIL3
IEC 13849-1: 2006, EN ISO 13849-1: 2008 (PLe, Cat.4)
UL 508, UL 1998, CAN/CSA C22.2 No.14, CAN/CSA C22.2 No.0.8
477
F3SJ-A Safety sensors
Response Time
Model Protected height (mm) Number of beams Response time ms (ON to OFF) Response time ms (OFF to ON)
F3SJ-A 14 Series 245 to 263 26 to 28 11 44
281 to 389 30 to 42 12 48
407 to 497 44 to 54 13 52
515 to 605 56 to 66 14 56
623 to 731 68 to 80 15 60
767 to 983 84 to 108 17.5 70
1,055 to 1,271 116 to 140 20 80
1,343 to 1,559 148 to 172 22.5 90
1,631 180 25 100
F3SJ-A 30 Series 245 to 395 10 to 16 10 40
420 to 720 17 to 29 11 44
745 to 1,045 30 to 42 12 48
1,070 to 1,295 43 to 52 13 52
1,395 to 1,620 56 to 65 14 56
1,745 to 1,995 70 to 80 15 60
2,120 to 2,495 85 to 100 17.5 70
Note: Use the following expressions for series connection.
• For 2-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit – 1 (ms), Response time (OFF to ON): Response time calculated by the above × 4 (ms)
• For 3-set series connection: Response time (ON to OFF):
Response time of the 1st unit + Response time of the 2nd unit + Response time of 3rd unit – 5 (ms), Response time (OFF to ON): Response time calculated by the above × 5 (ms)
For models with the “-TS” suffix, multiply the response time obtained by the above × 5 (ms), or use 200 ms, whichever is less.)
• For 4-set series connection:
Response time (ON to OFF): Response time of the 1st unit + Response time of the 2nd unit + Response time of the 3rd unit + Response time of the 4th unit – 8 (ms) Response time (OFF to ON): Response time calculated by the above × 5 (ms)
Cable extension length
Total cable extension length must be no greater than the lengths described below.
When the F3SJ and an external power supply are directly connected, or when the F3SJ is connected to a G9SA-300-SC.
Condition 1 set 2 sets 3 sets 4 sets
Using incandescent lamp for auxiliary output and external indicator output
45 m 40 m 30 m 20 m
Not using incandescent lamp 100 m 60 m 45 m 30 m
When connected to the F3SP-B1P
Condition 1 set 2 sets 3 sets 4 sets Using incandescent lamp for external indicator output 2 40 m 30 m 25 m 20 m Using incandescent lamp for external indicator output 1 60 m 45 m 30 m 20 m Using incandescent lamp for auxiliary output 1
Not using incandescent lamp 100 m 60 m 45 m 30 m
Note: Keep the cable length within the rated length. Failure to do so is dangerous as it may prevent safety functions from operating normally.
478
F3SJ-A Safety sensors
Connections
Basic Wiring Diagram
PNP Output
Wiring when using manual reset mode, external device monitoring.
(Gray) Communication line (+) (Pink)
Communication
line (−)
S1 : External test switch (connect to 0 V if a switch is not required) S2 : Interlock/lockout reset switch
KM1, KM2 : Safety relay with force-guided contact (G7SA) or magnetic contactor
K1, K2 : Load or PLC, etc. (for monitoring)
*1. Use a switch for small loads (input specifications: 24 V, 1.8 mA).
*2. F3SJ operates even when K1 and K2 are not connected.
K2 S1 S2
KM1
K1
KM1 KM2
*2 *1 *1
KM2 *2
+24 VDC Power
0 V supply
479

Datasheet - PDF

Title:Language:Size:Type:
pdf1-mostradoFree location mounting brackets for F3SJ set of 2 - OMRON - F39-LJ3 - 189910English340 Kbytespdf1-mostradoFree location mounting brackets for F3SJ set of 2 - OMRON - F39-LJ3 - 189910
pdf1-Free location mounting brackets for F3SJ set of 2 - OMRON - F39-LJ3 - 189910English16 Mbytespdf1-mostradoFree location mounting brackets for F3SJ set of 2 - OMRON - F39-LJ3 - 189910

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or