150W Single Output Switching Power Supply
150W Single Output Switching Power Supply
150W Single Output Switching Power SupplyFeatures :
Features :
Features :
HLG-150Hseries
HLG-150Hseries
HLG-150Hseries
Universal AC input / Full range (up to 305VAC)
Universal AC input / Full range (up to 305VAC)
Universal AC input / Full range (up to 305VAC)
Built-in active PFC function
Built-in active PFC function
Built-in active PFC function
High efficiency up to 94%
High efficiency up to 94%
High efficiency up to 94%
Protections: Short circuit / Over current / Over voltage / Over temperature
Protections: Short circuit / Over current / Over voltage / Over temperature
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Cooling by free air convection
Cooling by free air convection
OCP point adjustable throughoutputcable or internalpotentiometer
OCP point adjustable throughoutputcable or internalpotentiometer
OCP point adjustable throughoutputcable or internalpotentiometer
IP67 / IP65 design for indoor or outdoor installations
IP67 / IP65 design for indoor or outdoor installations
IP67 / IP65 design for indoor or outdoor installations
Three in one dimming function (1D10Vdcor PWM signal or resistance)
Three in one dimming function (1D10Vdcor PWM signal or resistance)
Three in one dimming function (1D10Vdcor PWM signal or resistance)
Suitable for LED lighting and street lighting applications
Suitable for LED lighting and street lighting applications
Suitable for LED lighting and street lighting applications
Compliance to worldwide safety regulations for lighting
Compliance to worldwide safety regulations for lighting
Compliance to worldwide safety regulations for lighting
Suitable for dry / damp / wet locations
Suitable for dry / damp / wet locations
Suitable for dry / damp / wet locations
Type "HL" for use in class I, Division2 hazardous(Classified) location luminaires
Type "HL" for use in class I, Division2 hazardous(Classified) location luminaires
Type "HL" for use in class I, Division2 hazardous(Classified) location luminaires
7 years warranty(Note.10)
7 years warranty(Note.10)
7 years warranty(Note.10)F110
F110
F110MM SELVIP65 IP67
MM SELVIP65 IP67
MM SELVIP65 IP67Bauar t gepr u f t
Bauar t gepr u f t
Bauar t gepr u f t
Sicherheit egel mage
Sicherheit egel mage
Sicherheit egel mage
cdcs
cdcs
cdcs
bewacg
bewacg
bewacg
Type HL
Type HL
Type HL
www. tuv. ccm
www. tuv. ccm
www. tuv. ccm
ID2000000000
ID2000000000
ID2000000000HLG-150H-12A
HLG-150H-12A
HLG-150H-12ABlank : IP67 rated. Cable for I/O connection.
Blank : IP67 rated. Cable for I/O connection.
Blank : IP67 rated. Cable for I/O connection.
A : IP65 rated.Output voltageand constant currentlevel can be adjusted throughinternal potentiometer.
A : IP65 rated.Output voltageand constant currentlevel can be adjusted throughinternal potentiometer.
A : IP65 rated.Output voltageand constant currentlevel can be adjusted throughinternal potentiometer.
B : IP67 rated. Constant current level adjustablethrough output cable with 1D10Vdc or 10V PWM signal or resistance. D (option, safety pending) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
B : IP67 rated. Constant current level adjustablethrough output cable with 1D10Vdc or 10V PWM signal or resistance. D (option, safety pending) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
B : IP67 rated. Constant current level adjustablethrough output cable with 1D10Vdc or 10V PWM signal or resistance. D (option, safety pending) : IP67 rated. Timer dimming function, contact MEAN WELL for details.SPECIFICATION
SPECIFICATION
SPECIFICATION
MODEL
MODEL
MODEL
DC VOLTAGE
DC VOLTAGE
DC VOLTAGEHLG-150H-12 HLG-150H-15HLG-150H-20 HLG-150H-24HLG-150H-30 HLG-150H-36
HLG-150H-12 HLG-150H-15HLG-150H-20 HLG-150H-24HLG-150H-30 HLG-150H-36
HLG-150H-12 HLG-150H-15HLG-150H-20 HLG-150H-24HLG-150H-30 HLG-150H-36
12V15V 20V 24V 30V 36V
12V15V 20V 24V 30V 36V
12V15V 20V 24V 30V 36VHLG-150H-42
HLG-150H-42
HLG-150H-42
42V
42V
42VHLG-150H-48
HLG-150H-48
HLG-150H-48
48V
48V
48VHLG-150H-54
HLG-150H-54
HLG-150H-54
54V
54V
54V
CONSTANT CURRENT REGION Note.4 6 ~12V7.5 ~ 15V10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V
CONSTANT CURRENT REGION Note.4 6 ~12V7.5 ~ 15V10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V
CONSTANT CURRENT REGION Note.4 6 ~12V7.5 ~ 15V10 ~ 20V 12 ~ 24V 15 ~ 30V 18 ~ 36V
21 ~ 42V
21 ~ 42V
21 ~ 42V
24 ~ 48V 27 ~ 54V
24 ~ 48V 27 ~ 54V
24 ~ 48V 27 ~ 54V
RATED CURRENT RATED POWER
RATED CURRENT RATED POWER
RATED CURRENT RATED POWER
12.5A10A 7.5A6.3A5A 4.2A
12.5A10A 7.5A6.3A5A 4.2A
12.5A10A 7.5A6.3A5A 4.2A
150W150W150W151.2W 150W151.2W
150W150W150W151.2W 150W151.2W
150W150W150W151.2W 150W151.2W
3.6A
3.6A
3.6A
151.2W
151.2W
151.2W
3.2A
3.2A
3.2A
153.6W
153.6W
153.6W
2.8A
2.8A
2.8A
151.2W
151.2W
151.2W
RIPPLE & NOISE (max.) Note.2150mVp-p 150mVp-p
RIPPLE & NOISE (max.) Note.2150mVp-p 150mVp-p
RIPPLE & NOISE (max.) Note.2150mVp-p 150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
150mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
200mVp-p
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V
VOLTAGE ADJ. RANGE Note.6 10.8 ~ 13.5V
13.5 ~ 17V
13.5 ~ 17V
13.5 ~ 17V
17 ~ 22V
17 ~ 22V
17 ~ 22V
22 ~ 27V
22 ~ 27V
22 ~ 27V
27 ~ 33V
27 ~ 33V
27 ~ 33V
33 ~ 40V
33 ~ 40V
33 ~ 40V
38 ~ 46V
38 ~ 46V
38 ~ 46V
43 ~ 53V
43 ~ 53V
43 ~ 53V
49 ~ 58V
49 ~ 58V
49 ~ 58V
OUTPUT
OUTPUT
OUTPUTCURRENT ADJ. RANGE
CURRENT ADJ. RANGE
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer A type only
Can be adjusted by internal potentiometer A type only
Can be adjusted by internal potentiometer A type only
7.5 ~ 12.5A 6 ~ 10A 4.5 ~ 7.5A 3.8 ~ 6.3A 3 ~ 5A 2.5 ~ 4.2A
7.5 ~ 12.5A 6 ~ 10A 4.5 ~ 7.5A 3.8 ~ 6.3A 3 ~ 5A 2.5 ~ 4.2A
7.5 ~ 12.5A 6 ~ 10A 4.5 ~ 7.5A 3.8 ~ 6.3A 3 ~ 5A 2.5 ~ 4.2A2.16 ~ 3.6A
2.16 ~ 3.6A
2.16 ~ 3.6A1.92 ~ 3.2A 1.68 ~ 2.8A
1.92 ~ 3.2A 1.68 ~ 2.8A
1.92 ~ 3.2A 1.68 ~ 2.8A
VOLTAGE TOLERANCE Note.3 2.5%2.0%1.0%1.0%1.0%1.0%
VOLTAGE TOLERANCE Note.3 2.5%2.0%1.0%1.0%1.0%1.0%
VOLTAGE TOLERANCE Note.3 2.5%2.0%1.0%1.0%1.0%1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
1.0%
LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION
0.5%0.5%0.5%0.5%0.5%0.5%
0.5%0.5%0.5%0.5%0.5%0.5%
0.5%0.5%0.5%0.5%0.5%0.5%
2.0%1.5%1.0%0.5%0.5%0.5%
2.0%1.5%1.0%0.5%0.5%0.5%
2.0%1.5%1.0%0.5%0.5%0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
0.5%
SETUP, RISE TIME Note.81000ms,50ms/115VAC500ms,50ms/230VAC at full load ; B type 1000ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
SETUP, RISE TIME Note.81000ms,50ms/115VAC500ms,50ms/230VAC at full load ; B type 1000ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
SETUP, RISE TIME Note.81000ms,50ms/115VAC500ms,50ms/230VAC at full load ; B type 1000ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
HOLD UP TIME (Typ.)
HOLD UP TIME (Typ.)
HOLD UP TIME (Typ.)
16ms at full load230VAC / 115VAC
16ms at full load230VAC / 115VAC
16ms at full load230VAC / 115VAC
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
VOLTAGE RANGE Note.5 90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE POWER FACTOR (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.)
47 ~ 63Hz
47 ~ 63Hz
47 ~ 63Hz
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION THD< 20% when output loading60% at 115VAC/230VAC input and output loading75% at 277VAC input
TOTAL HARMONIC DISTORTION THD< 20% when output loading60% at 115VAC/230VAC input and output loading75% at 277VAC input
TOTAL HARMONIC DISTORTION THD< 20% when output loading60% at 115VAC/230VAC input and output loading75% at 277VAC inputINPUT
INPUT
INPUT
EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
MAX. No. of PSUs on 16A
MAX. No. of PSUs on 16A
MAX. No. of PSUs on 16A
91.5%92% 93% 93% 93.5% 93.5%
91.5%92% 93% 93% 93.5% 93.5%
91.5%92% 93% 93% 93.5% 93.5%
1.7A / 115VAC 0.75A / 230VAC 0.7A / 277VAC
1.7A / 115VAC 0.75A / 230VAC 0.7A / 277VAC
1.7A / 115VAC 0.75A / 230VAC 0.7A / 277VAC
COLD START 65A(twidth=425s measured at 50% Ipeak) at 230VAC
COLD START 65A(twidth=425s measured at 50% Ipeak) at 230VAC
COLD START 65A(twidth=425s measured at 50% Ipeak) at 230VAC
94%
94%
94%
94%
94%
94%
94%
94%
94%
CIRCUIT BREAKER4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
CIRCUIT BREAKER4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
CIRCUIT BREAKER4 units (circuit breaker of type B) / 7 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT OVER CURRENT
LEAKAGE CURRENT OVER CURRENT
LEAKAGE CURRENT OVER CURRENT
<0.75mA / 277VAC
<0.75mA / 277VAC
<0.75mA / 277VAC
95 ~ 108%
95 ~ 108%
95 ~ 108%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removedPROTECTION
PROTECTION
PROTECTION
SHORT CIRCUITConstant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUITConstant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUITConstant current limiting, recovers automatically after fault condition is removed
14 ~ 17V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V
14 ~ 17V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V
14 ~ 17V 18 ~ 21V 23 ~ 27V 28 ~ 34V 34 ~ 38V 41 ~ 46V47 ~ 53V
47 ~ 53V
47 ~ 53V54 ~ 63V
54 ~ 63V
54 ~ 63V59 ~ 65V
59 ~ 65V
59 ~ 65V
OVER VOLTAGE
OVER VOLTAGE
OVER VOLTAGEOVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT VIBRATION
TEMP. COEFFICIENT VIBRATION
TEMP. COEFFICIENT VIBRATION
SAFETY STANDARDS Note.7
SAFETY STANDARDS Note.7
SAFETY STANDARDS Note.7
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Shut down o/p voltage, recovers automatically after temperature goes down
Shut down o/p voltage, recovers automatically after temperature goes down
Shut down o/p voltage, recovers automatically after temperature goes down
-40 ~ +70c (Refer to "Derating Curve")
-40 ~ +70c (Refer to "Derating Curve")
-40 ~ +70c (Refer to "Derating Curve")
20 ~ 95% RH non-condensing
20 ~ 95% RH non-condensing
20 ~ 95% RH non-condensing
-40 ~ +80, 10 ~ 95% RH
-40 ~ +80, 10 ~ 95% RH
-40 ~ +80, 10 ~ 95% RH
0.03%/c (0 ~ 50c)
0.03%/c (0 ~ 50c)
0.03%/c (0 ~ 50c)
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
UL8750(typeHL), CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1
UL8750(typeHL), CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1
UL8750(typeHL), CSA C22.2 No. 250.0-08, EN61347-1, EN61347-2-13 independent IP65 or IP67, J61347-1, J61347-2-13 approved ; design refer to UL60950-1, TUV EN60950-1
SAFETY & EMC
SAFETY & EMC
SAFETY & EMCOTHERS
OTHERS
OTHERS
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION
PACKING
PACKING
PACKING
I/P-O/P:3.75KVACI/P-FG:2KVACO/P-FG:1.5KVAC
I/P-O/P:3.75KVACI/P-FG:2KVACO/P-FG:1.5KVAC
I/P-O/P:3.75KVACI/P-FG:2KVACO/P-FG:1.5KVAC
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (60% load) ; EN61000-3-3
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (60% load) ; EN61000-3-3
Compliance to EN55015, EN55022 (CISPR22) Class B, EN61000-3-2 Class C (60% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A
192.2K hrs min. MIL-HDBK-217F (25c)
192.2K hrs min. MIL-HDBK-217F (25c)
192.2K hrs min. MIL-HDBK-217F (25c)
228*68*38.8mm
228*68*38.8mm
228*68*38.8mm
1.15Kg; 12pcs/14.8Kg/0.8CUFT
1.15Kg; 12pcs/14.8Kg/0.8CUFT
1.15Kg; 12pcs/14.8Kg/0.8CUFTNOTE
NOTE
NOTE
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25c of ambient temperature.
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25c of ambient temperature.
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25c of ambient temperature.
2. Ripple & noiseare measured at 20MHz of bandwidth by usinga 12" twistedpair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Ripple & noiseare measured at 20MHz of bandwidth by usinga 12" twistedpair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Ripple & noiseare measured at 20MHz of bandwidth by usinga 12" twistedpair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Please refer to "DRIVING METHODS OF LED MODULE".
4. Please refer to "DRIVING METHODS OF LED MODULE".
4. Please refer to "DRIVING METHODS OF LED MODULE".
5. Derating may be needed under low input voltages. Please check the static characteristics for moredetails.
5. Derating may be needed under low input voltages. Please check the static characteristics for moredetails.
5. Derating may be needed under low input voltages. Please check the static characteristics for moredetails.
6. A type only.
6. A type only.
6. A type only.
7. Safetyand EMC design refer to EN60598-1, subject 8750(UL),CNS15233, GB7000.1, FCC part18.
7. Safetyand EMC design refer to EN60598-1, subject 8750(UL),CNS15233, GB7000.1, FCC part18.
7. Safetyand EMC design refer to EN60598-1, subject 8750(UL),CNS15233, GB7000.1, FCC part18.
8. Lengthof set up time is measured at cold first start. Turning ON/OFFthe powersupply may lead to increase of the set up time.
8. Lengthof set up time is measured at cold first start. Turning ON/OFFthe powersupply may lead to increase of the set up time.
8. Lengthof set up time is measured at cold first start. Turning ON/OFFthe powersupply may lead to increase of the set up time.
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers mustre-qualify EMC Directive on the complete installation again.
complete installation, the final equipment manufacturers mustre-qualify EMC Directive on the complete installation again.
complete installation, the final equipment manufacturers mustre-qualify EMC Directive on the complete installation again.
10. Referto warranty statement.
10. Referto warranty statement.
10. Referto warranty statement.
11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
connected to the mains.
connected to the mains.
connected to the mains.
File Name:HLG-150H-SPEC 2015-08-19
File Name:HLG-150H-SPEC 2015-08-19
File Name:HLG-150H-SPEC 2015-08-19