HLG-120H-48D MEANWELL AC-DC Single output LED driver Mix mode (CV+CC) with built-in PFC, Output 48VDC / 2.5A.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HLG-120H-48D MEANWELL AC-DC Single output LED driver Mix mode (CV+CC) with built-in PFC, Output 48VDC / 2.5A..

HLG-120H-48D

MEANWELL

Available Ship on today

AC-DC Single output LED driver Mix mode (CV+CC) with built-in PFC, Output 48VDC / 2.5A, IP67, Timer dimming function

More details


LED DRIVERS > HLG

* Brand new product in its original packaging covered by the warranties and certifications provided by MEANWELL

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



150W Single Output LED Power SupplyHLG-120H-Cseries 150W Single Output LED Power SupplyHLG-120H-Cseries
150W Single Output LED Power SupplyHLG-120H-CseriesFeatures : Features :
Features : Constant currentdesign Constant currentdesign
Constant currentdesign Universal AC input / Full range (up to 305VAC) Universal AC input / Full range (up to 305VAC)
Universal AC input / Full range (up to 305VAC) Built-in active PFC function Built-in active PFC function
Built-in active PFC function High efficiency up to 94% High efficiency up to 94%
High efficiency up to 94% Protections: Short circuit / Over voltage/ Over temperature Protections: Short circuit / Over voltage/ Over temperature
Protections: Short circuit / Over voltage/ Over temperature Cooling by free air convection Cooling by free air convection
Cooling by free air convection Output currentadjustable throughoutput cableor internal potentiometer Output currentadjustable throughoutput cableor internal potentiometer
Output currentadjustable throughoutput cableor internal potentiometer IP67 / IP65 design for indoor or outdoorinstallations IP67 / IP65 design for indoor or outdoorinstallations
IP67 / IP65 design for indoor or outdoorinstallations Three in one dimming function (1=10Vdcor 10V PWM signal or resistance) Three in one dimming function (1=10Vdcor 10V PWM signal or resistance)
Three in one dimming function (1=10Vdcor 10V PWM signal or resistance) Suitable for dry / damp/ wet locations Suitable for dry / damp/ wet locations
Suitable for dry / damp/ wet locations 7 years warranty (Note.5) 7 years warranty (Note.5)
7 years warranty (Note.5)F110 F110
F110MM IP65 IP67 MM IP65 IP67
MM IP65 IP67HLG-120H-C350 A HLG-120H-C350 A
HLG-120H-C350 A A : IP65 rated.Constant currentlevel can be adjusted throughinternal potentiometer. A : IP65 rated.Constant currentlevel can be adjusted throughinternal potentiometer.
A : IP65 rated.Constant currentlevel can be adjusted throughinternal potentiometer. B : IP67 rated. Constantcurrent level adjustablethrough output cable with 1=10Vdc or 10V PWM signal or resistance. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details. B : IP67 rated. Constantcurrent level adjustablethrough output cable with 1=10Vdc or 10V PWM signal or resistance. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.
B : IP67 rated. Constantcurrent level adjustablethrough output cable with 1=10Vdc or 10V PWM signal or resistance. D (option) : IP67 rated. Timer dimming function, contact MEAN WELL for details.SPECIFICATION SPECIFICATION
SPECIFICATION MODEL MODEL
MODEL HLG-120H-C350HLG-120H-C500HLG-120H-C700HLG-120H-C1050HLG-120H-C1400 HLG-120H-C350HLG-120H-C500HLG-120H-C700HLG-120H-C1050HLG-120H-C1400
HLG-120H-C350HLG-120H-C500HLG-120H-C700HLG-120H-C1050HLG-120H-C1400 RATED CURRENT RATED CURRENT
RATED CURRENT 350mA 350mA
350mA 500mA700mA1050mA1400mA 500mA700mA1050mA1400mA
500mA700mA1050mA1400mA CURRENT ACCURACY5.0% CURRENT ACCURACY5.0%
CURRENT ACCURACY5.0% CONSTANT CURRENT REGION Note.6 215 ~ 430V150V ~ 300V107V ~ 215V74V ~ 148V54V ~ 108V CONSTANT CURRENT REGION Note.6 215 ~ 430V150V ~ 300V107V ~ 215V74V ~ 148V54V ~ 108V
CONSTANT CURRENT REGION Note.6 215 ~ 430V150V ~ 300V107V ~ 215V74V ~ 148V54V ~ 108V RATED POWER RIPPLE CURRENT RATED POWER RIPPLE CURRENT
RATED POWER RIPPLE CURRENT 150.5W 150.5W
150.5W 5% 5%
5% 150W150.5W 155.4W 151.2W 150W150.5W 155.4W 151.2W
150W150.5W 155.4W 151.2W OUTPUT OUTPUT
OUTPUT RIPPLE & NOISE 2Vp-p1.5Vp-p1Vp-p1Vp-p1Vp-p RIPPLE & NOISE 2Vp-p1.5Vp-p1Vp-p1Vp-p1Vp-p
RIPPLE & NOISE 2Vp-p1.5Vp-p1Vp-p1Vp-p1Vp-p Can be adjusted by internal potentiometer (A type only) Can be adjusted by internal potentiometer (A type only)
Can be adjusted by internal potentiometer (A type only) CURRENT ADJ. RANGE CURRENT ADJ. RANGE
CURRENT ADJ. RANGE 175 ~ 350mA 250 ~ 500mA 175 ~ 350mA 250 ~ 500mA
175 ~ 350mA 250 ~ 500mA 350 ~ 700mA 350 ~ 700mA
350 ~ 700mA 525 ~ 1050mA 525 ~ 1050mA
525 ~ 1050mA 700 ~ 1400mA 700 ~ 1400mA
700 ~ 1400mA LINE REGULATION1% LINE REGULATION1%
LINE REGULATION1% 1% 1%
1% 1% 1%
1% 1% 1%
1% 1% 1%
1% SETUP, RISE TIME HOLD UP TIME (Typ.) SETUP, RISE TIME HOLD UP TIME (Typ.)
SETUP, RISE TIME HOLD UP TIME (Typ.) 1000ms, 80ms / 115VAC at full load500ms, 80ms / 230VAC at full load 1000ms, 80ms / 115VAC at full load500ms, 80ms / 230VAC at full load
1000ms, 80ms / 115VAC at full load500ms, 80ms / 230VAC at full load 16ms at full load 230VAC / 115VAC 16ms at full load 230VAC / 115VAC
16ms at full load 230VAC / 115VAC VOLTAGE RANGE Note.2 90 ~ 305VAC127VDC ~ 431VDC VOLTAGE RANGE Note.2 90 ~ 305VAC127VDC ~ 431VDC
VOLTAGE RANGE Note.2 90 ~ 305VAC127VDC ~ 431VDC FREQUENCY RANGE POWER FACTOR (Typ.) FREQUENCY RANGE POWER FACTOR (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.) 47 ~ 63Hz 47 ~ 63Hz
47 ~ 63Hz PF>0.98/115VAC, PF>0.96/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve) PF>0.98/115VAC, PF>0.96/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
PF>0.98/115VAC, PF>0.96/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve)INPUT INPUT
INPUT TOTAL HARMONIC DISTORTION THD< 20% when output loading50% at 115VAC/230VAC input and output loading75% at 277VAC input TOTAL HARMONIC DISTORTION THD< 20% when output loading50% at 115VAC/230VAC input and output loading75% at 277VAC input
TOTAL HARMONIC DISTORTION THD< 20% when output loading50% at 115VAC/230VAC input and output loading75% at 277VAC input EFFICIENCY (Typ.) EFFICIENCY (Typ.)
EFFICIENCY (Typ.) 94% 94%
94% 94% 94%
94% 94% 94%
94% 94% 94%
94% 93.5% 93.5%
93.5% AC CURRENT (Typ.) INRUSH CURRENT (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
AC CURRENT (Typ.) INRUSH CURRENT (Typ.) MAX. No. of PSUs on 16A MAX. No. of PSUs on 16A
MAX. No. of PSUs on 16A 1.6A / 115VAC 0.8 A / 230VAC 0.7A / 277VAC COLD START 50A(twidth=600s measured at 50% Ipeak) at 230VAC 1.6A / 115VAC 0.8 A / 230VAC 0.7A / 277VAC COLD START 50A(twidth=600s measured at 50% Ipeak) at 230VAC
1.6A / 115VAC 0.8 A / 230VAC 0.7A / 277VAC COLD START 50A(twidth=600s measured at 50% Ipeak) at 230VAC CIRCUIT BREAKER 4 units (circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC CIRCUIT BREAKER 4 units (circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC
CIRCUIT BREAKER 4 units (circuit breaker of type B) / 6 units(circuit breaker of type C) at 230VAC LEAKAGE CURRENT SHORT CIRCUIT LEAKAGE CURRENT SHORT CIRCUIT
LEAKAGE CURRENT SHORT CIRCUIT <0.75mA / 277VAC <0.75mA / 277VAC
<0.75mA / 277VAC Constant current limiting, recovers automatically after fault condition is removed Constant current limiting, recovers automatically after fault condition is removed
Constant current limiting, recovers automatically after fault condition is removed 475 ~ 495V 475 ~ 495V
475 ~ 495V 335 ~ 355V 335 ~ 355V
335 ~ 355V 240 ~ 260V 240 ~ 260V
240 ~ 260V 165 ~ 175V 165 ~ 175V
165 ~ 175V 120 ~ 130V 120 ~ 130V
120 ~ 130V PROTECTION PROTECTION
PROTECTION ENVIRONMENT ENVIRONMENT
ENVIRONMENT OVER VOLTAGE OVER VOLTAGE
OVER VOLTAGEOVER TEMPERATURE WORKING TEMP. OVER TEMPERATURE WORKING TEMP.
OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY WORKING HUMIDITY
WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT
STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION VIBRATION
VIBRATION Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery Shut down o/p voltage, recovers automatically after temperature goes down Shut down o/p voltage, recovers automatically after temperature goes down
Shut down o/p voltage, recovers automatically after temperature goes down -40 ~ +70c (Refer to "Derating Curve") -40 ~ +70c (Refer to "Derating Curve")
-40 ~ +70c (Refer to "Derating Curve") 10 ~ 95% RH non-condensing 10 ~ 95% RH non-condensing
10 ~ 95% RH non-condensing -40 ~ +80c, 10 ~ 95% RH -40 ~ +80c, 10 ~ 95% RH
-40 ~ +80c, 10 ~ 95% RH 0.03%/c (0 ~ 50c) 0.03%/c (0 ~ 50c)
0.03%/c (0 ~ 50c) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.12-13, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP65 or IP67, J61347-1, J61347-2-13 approved SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.12-13, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP65 or IP67, J61347-1, J61347-2-13 approved
SAFETY STANDARDS Note.3 UL8750, CSA C22.2 No. 250.12-13, ENEC EN61347-1, EN61347-2-13, EN62384 independent, IP65 or IP67, J61347-1, J61347-2-13 approvedSAFETY & EMC SAFETY & EMC
SAFETY & EMCOTHERS OTHERS
OTHERS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION PACKING PACKING
PACKING I/P-O/P:3.75KVAC I/P-FG:2KVACO/P-FG:1.5KVAC I/P-O/P:3.75KVAC I/P-FG:2KVACO/P-FG:1.5KVAC
I/P-O/P:3.75KVAC I/P-FG:2KVACO/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25c/ 70% RH Compliance to EN55015, EN61000-3-2 Class C (50% load) ; EN61000-3-3 Compliance to EN55015, EN61000-3-2 Class C (50% load) ; EN61000-3-3
Compliance to EN55015, EN61000-3-2 Class C (50% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge L,N-FG: 4KV), criteria A Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge L,N-FG: 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge L,N-FG: 4KV), criteria A 191.1K hrs min.MIL-HDBK-217F (25c) 191.1K hrs min.MIL-HDBK-217F (25c)
191.1K hrs min.MIL-HDBK-217F (25c) 220*68*38.8mm (L*W*H) 220*68*38.8mm (L*W*H)
220*68*38.8mm (L*W*H) 1.04Kg; 12pcs/13.5Kg/0.8CUFT 1.04Kg; 12pcs/13.5Kg/0.8CUFT
1.04Kg; 12pcs/13.5Kg/0.8CUFTNOTE NOTE
NOTE 1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25c of ambient temperature. 1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25c of ambient temperature.
1. All parameters NOT speciallymentioned are measured at 230VAC input, ratedload and 25c of ambient temperature. 2. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details. 2. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details.
2. Deratingmay be needed underlow input voltages. Please checkthe static characteristics for more details. 3. Safetyand EMC design refer to EN60598-1, CNS15233, GB7000.1. 3. Safetyand EMC design refer to EN60598-1, CNS15233, GB7000.1.
3. Safetyand EMC design refer to EN60598-1, CNS15233, GB7000.1. 4. The powersupply is considered as a component that will be operated in combination with final equipment. SinceEMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain. 4. The powersupply is considered as a component that will be operated in combination with final equipment. SinceEMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
4. The powersupply is considered as a component that will be operated in combination with final equipment. SinceEMC performance will be affected by the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain. 5. Referto warrantystatement. 5. Referto warrantystatement.
5. Referto warrantystatement. 6. Please refer to "DRIVING METHODS OF LED MODULE". 6. Please refer to "DRIVING METHODS OF LED MODULE".
6. Please refer to "DRIVING METHODS OF LED MODULE". 7. To fulfill requirements of the latestErP regulation for lighting fixtures, this LED power supply canonly be used behinda switch without permanently connected to the mains. 7. To fulfill requirements of the latestErP regulation for lighting fixtures, this LED power supply canonly be used behinda switch without permanently connected to the mains.
7. To fulfill requirements of the latestErP regulation for lighting fixtures, this LED power supply canonly be used behinda switch without permanently connected to the mains. File Name:HLG-120H-C-SPEC2015-07-23 File Name:HLG-120H-C-SPEC2015-07-23
File Name:HLG-120H-C-SPEC2015-07-23

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.