12W AC-DCIndustrialAdaptorGS12Useries
12W AC-DCIndustrialAdaptorGS12Useries
12W AC-DCIndustrialAdaptorGS12Useries
Features :
Features :
Features :
UniversalAC input / Full range
UniversalAC input / Full range
UniversalAC input / Full range
No load powerconsumptione 0.3W
No load powerconsumptione 0.3W
No load powerconsumptione 0.3W
EnergyefficiencyLevelV
EnergyefficiencyLevelV
EnergyefficiencyLevelV
Comply with EISA 2007
Comply with EISA 2007
Comply with EISA 2007
2 pole USA plug
2 pole USA plug
2 pole USA plug
Class II power(without earthpin)
Class II power(without earthpin)
Class II power(without earthpin)
Protections: Short circuit / Overload / Over Voltage / Over temperature
Protections: Short circuit / Overload / Over Voltage / Over temperature
Protections: Short circuit / Overload / Over Voltage / Over temperature
Pass LPS
Pass LPS
Pass LPS
Fully enclosed plastic case
Fully enclosed plastic case
Fully enclosed plastic case
2 years warranty
2 years warranty
2 years warranty
SPECIFICATION
SPECIFICATION
SPECIFICATION
ORDER NO.
ORDER NO.
ORDER NO.
GS12U05-P1IGS12U07-P1IGS12U09-P1IGS12U12-P1IGS12U15-P1IGS12U18-P1IGS12U24-P1I
GS12U05-P1IGS12U07-P1IGS12U09-P1IGS12U12-P1IGS12U15-P1IGS12U18-P1IGS12U24-P1I
GS12U05-P1IGS12U07-P1IGS12U09-P1IGS12U12-P1IGS12U15-P1IGS12U18-P1IGS12U24-P1I
SAFETY MODEL NO. DC VOLTAGE
SAFETY MODEL NO. DC VOLTAGE
SAFETY MODEL NO. DC VOLTAGE
RATED CURRENT
RATED CURRENT
RATED CURRENT
CURRENT RANGE
CURRENT RANGE
CURRENT RANGE
GS12U05
GS12U05
GS12U05
5V
5V
5V
2.0A
2.0A
2.0A
0 ~ 2.0A
0 ~ 2.0A
0 ~ 2.0A
GS12U07
GS12U07
GS12U07
7.5V
7.5V
7.5V
1.6A
1.6A
1.6A
0 ~ 1.6A
0 ~ 1.6A
0 ~ 1.6A
GS12U09
GS12U09
GS12U09
9V
9V
9V
1.33A
1.33A
1.33A
0 ~ 1.33A
0 ~ 1.33A
0 ~ 1.33A
GS12U12 GS12U15 GS12U18 GS12U24
GS12U12 GS12U15 GS12U18 GS12U24
GS12U12 GS12U15 GS12U18 GS12U24
12V15V 18V24V
12V15V 18V24V
12V15V 18V24V
1.0A 0.8A 0.67A 0.5A
1.0A 0.8A 0.67A 0.5A
1.0A 0.8A 0.67A 0.5A
0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.67A 0 ~ 0.5A
0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.67A 0 ~ 0.5A
0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.67A 0 ~ 0.5AOUTPUT
OUTPUT
OUTPUT
RATED POWER
RATED POWER
RATED POWER
10W
10W
10W
12W
12W
12W
12W
12W
12W
12W 12W
12W 12W
12W 12W
12.06W12W
12.06W12W
12.06W12W
RIPPLE & NOISE (max.) Note.2 75mVp-p
RIPPLE & NOISE (max.) Note.2 75mVp-p
RIPPLE & NOISE (max.) Note.2 75mVp-p
90mVp-p
90mVp-p
90mVp-p
90mVp-p
90mVp-p
90mVp-p
120mVp-p150mVp-p180mVp-p200mVp-p
120mVp-p150mVp-p180mVp-p200mVp-p
120mVp-p150mVp-p180mVp-p200mVp-p
VOLTAGE TOLERANCE Note.3 5.0%
VOLTAGE TOLERANCE Note.3 5.0%
VOLTAGE TOLERANCE Note.3 5.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%
3.0%3.0%
3.0%3.0%
3.0%3.0%
LINE REGULATIONNote.41.0%1.0%1.0%1.0%1.0%
LINE REGULATIONNote.41.0%1.0%1.0%1.0%1.0%
LINE REGULATIONNote.41.0%1.0%1.0%1.0%1.0%
1.0%1.0%
1.0%1.0%
1.0%1.0%
LOAD REGULATIONNote.55.0%
LOAD REGULATIONNote.55.0%
LOAD REGULATIONNote.55.0%
4.0%
4.0%
4.0%
4.0%
4.0%
4.0%
3.0%
3.0%
3.0%
3.0%2.0%2.0%
3.0%2.0%2.0%
3.0%2.0%2.0%
SETUP, RISE, HOLD UP TIME VOLTAGE RANGE
SETUP, RISE, HOLD UP TIME VOLTAGE RANGE
SETUP, RISE, HOLD UP TIME VOLTAGE RANGE
FREQUENCY RANGE
FREQUENCY RANGE
FREQUENCY RANGE
500ms, 20ms, 30ms/230VAC 500ms, 20ms, 10ms/115VACat full load
500ms, 20ms, 30ms/230VAC 500ms, 20ms, 10ms/115VACat full load
500ms, 20ms, 30ms/230VAC 500ms, 20ms, 10ms/115VACat full load
90 ~ 264VAC135 ~ 370VDC
90 ~ 264VAC135 ~ 370VDC
90 ~ 264VAC135 ~ 370VDC
47 ~ 63Hz
47 ~ 63Hz
47 ~ 63HzINPUT
INPUT
INPUT
EFFICIENCY (Typ.)
EFFICIENCY (Typ.)
EFFICIENCY (Typ.)
76%
76%
76%
78.5%
78.5%
78.5%
78.5%
78.5%
78.5%
78.5% 80%80%80.5%
78.5% 80%80%80.5%
78.5% 80%80%80.5%
PROTECTION
PROTECTION
PROTECTION
AC CURRENT
AC CURRENT
AC CURRENT
INRUSH CURRENT (max.) LEAKAGE CURRENT (max.)
INRUSH CURRENT (max.) LEAKAGE CURRENT (max.)
INRUSH CURRENT (max.) LEAKAGE CURRENT (max.)
OVERLOAD OVER VOLTAGE
OVERLOAD OVER VOLTAGE
OVERLOAD OVER VOLTAGE
OVER TEMPERATURENote.6
OVER TEMPERATURENote.6
OVER TEMPERATURENote.6WORKING TEMP. WORKING HUMIDITY
WORKING TEMP. WORKING HUMIDITY
WORKING TEMP. WORKING HUMIDITY
0.31A / 115VAC 0.16A / 230VAC
0.31A / 115VAC 0.16A / 230VAC
0.31A / 115VAC 0.16A / 230VAC
COLD START 25A / 115VAC45A / 230VAC
COLD START 25A / 115VAC45A / 230VAC
COLD START 25A / 115VAC45A / 230VAC
0.25mA / 240VAC
0.25mA / 240VAC
0.25mA / 240VAC
>105%rated output power
>105%rated output power
>105%rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
115% ~ 135%
115% ~ 135%
115% ~ 135%
Protection type : Clamp by zener diode
Protection type : Clamp by zener diode
Protection type : Clamp by zener diode
U1 Tj 140 typically (U1) Detect on main control IC
U1 Tj 140 typically (U1) Detect on main control IC
U1 Tj 140 typically (U1) Detect on main control IC
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
0 ~ +50 (Refer to "Derating Curve")
0 ~ +50 (Refer to "Derating Curve")
0 ~ +50 (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
20% ~ 90% RH non-condensing
20% ~ 90% RH non-condensing
ENVIRONMENTSTORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION
ENVIRONMENTSTORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION
ENVIRONMENTSTORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION
SAFETY STANDARDS
SAFETY STANDARDS
SAFETY STANDARDS
-20 ~ +85, 10 ~ 95% RH
-20 ~ +85, 10 ~ 95% RH
-20 ~ +85, 10 ~ 95% RH
0.03% /(0 ~ 40)
0.03% /(0 ~ 40)
0.03% /(0 ~ 40)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
UL60950-1, CSA22.2, BSMI CNS14336 approved
UL60950-1, CSA22.2, BSMI CNS14336 approved
UL60950-1, CSA22.2, BSMI CNS14336 approved
SAFETY & EMC
SAFETY & EMC
SAFETY & EMC
OTHERS
OTHERS
OTHERS
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
MTBF
MTBF
MTBF
DIMENSION
DIMENSION
DIMENSION
I/P-O/P:3KVAC
I/P-O/P:3KVAC
I/P-O/P:3KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
Compliance to FCC PART 15 / CISPR22 class B, CNS13438 class B
1414.6Khrs min.MIL-HDBK-217F (25)
1414.6Khrs min.MIL-HDBK-217F (25)
1414.6Khrs min.MIL-HDBK-217F (25)
65*47*26.5mm (L*W*H)
65*47*26.5mm (L*W*H)
65*47*26.5mm (L*W*H)
PACKING0.15Kg ; 100pcs / 16Kg / CARTON
PACKING0.15Kg ; 100pcs / 16Kg / CARTON
PACKING0.15Kg ; 100pcs / 16Kg / CARTONCONNECTOR
CONNECTOR
CONNECTOR
PLUG CABLE
PLUG CABLE
PLUG CABLE
See page 2; Other type available by customer requested
See page 2; Other type available by customer requested
See page 2; Other type available by customer requested
See page 2; Other type available by customer requested
See page 2; Other type available by customer requested
See page 2; Other type available by customer requestedNOTE
NOTE
NOTE
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
1.All parameters are specified at 115VAC input, rated load, 25 70% RH ambient.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
3.Tolerance: includes set up tolerance, line regulation, load regulation.
4.Line regulation is measured from low line to high line at rated load.
4.Line regulation is measured from low line to high line at rated load.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation is measured from 10% to 100% rated load.
5.Load regulation is measured from 10% to 100% rated load.
5.Load regulation is measured from 10% to 100% rated load.
6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification
6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification
6.The over temperature protection (OTP) is the built-in function of the control IC (U1). The activating level described above is based on the specification
providedby the IC manufacturer.
providedby the IC manufacturer.
providedby the IC manufacturer.
File Name:GS12U-SPEC2015-05-20
File Name:GS12U-SPEC2015-05-20
File Name:GS12U-SPEC2015-05-20