HSG-70-36 MEANWELL AC-DC Single output LED driver Mix mode (CV+CC), Output 36VDC / 2A, IP65, cable output, D.. View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HSG-70-36 MEANWELL AC-DC Single output LED driver Mix mode (CV+CC), Output 36VDC / 2A, IP65, cable output, D..

HSG-70-36

MEANWELL

Available Ship on today

AC-DC Single output LED driver Mix mode (CV+CC), Output 36VDC / 2A, IP65, cable output, Dimming with Potentiometer

More details


LED DRIVERS

* Brand new product in its original packaging covered by the warranties and certifications provided by MEANWELL

* This article may be obsolete. Ask for a quotation and we will check if there are any units available. If not, one of our technicians will look for an alternative solution.

Go to successor article: XLG-75-24-A XLG-75-24-A

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



70 W Single Output switching Power supply 70 W Single Output switching Power supply
70W Single Output Switching Power SupplyFeatures : Features :
Features : HSG-70series HSG-70series
HSG-70series UniversalAC input / Full range(up to 305VAC) UniversalAC input / Full range(up to 305VAC)
UniversalAC input / Full range(up to 305VAC) Protections:short circuit/overload/Over voltage/Over temperature Protections:short circuit/overload/Over voltage/Over temperature
Protections:short circuit/overload/Over voltage/Over temperature Built-in active PFC function Built-in active PFC function
Built-in active PFC function High efficiency, up to 90% High efficiency, up to 90%
High efficiency, up to 90% Cooling by free air convection Cooling by free air convection
Cooling by free air convection IP65 design for indoor and outdoorinstallations IP65 design for indoor and outdoorinstallations
IP65 design for indoor and outdoorinstallations Small and compact size Small and compact size
Small and compact size High reliability,low cost High reliability,low cost
High reliability,low cost Suitable for LED lighting and movingsign applications Suitable for LED lighting and movingsign applications
Suitable for LED lighting and movingsign applications 3 years warranty 3 years warranty
3 years warrantySPECIFICATION SPECIFICATION
SPECIFICATION MODEL MODEL
MODEL HSG-70-12 HSG-70-12
HSG-70-12 HSG-70-18 HSG-70-24 HSG-70-36 HSG-70-18 HSG-70-24 HSG-70-36
HSG-70-18 HSG-70-24 HSG-70-36 IP65 IP65
IP65HSG-70-48 HSG-70-48
HSG-70-48 THE DC VOLTAGE THE DC VOLTAGE
THE DC VOLTAGE 12V 12V
12V 18V 18V
18V 24V 24V
24V 36V 36V
36V 48V 48V
48V CONSTANT CURRENT REGION Note.57.7 ~ 12V CONSTANT CURRENT REGION Note.57.7 ~ 12V
CONSTANT CURRENT REGION Note.57.7 ~ 12V 11.3 ~ 18V 11.3 ~ 18V
11.3 ~ 18V 15.5 ~ 24V 15.5 ~ 24V
15.5 ~ 24V 22.1 ~ 36V 22.1 ~ 36V
22.1 ~ 36V 29.3 ~ 48V 29.3 ~ 48V
29.3 ~ 48V NOMINAL CURRENT NOMINAL POWER NOMINAL CURRENT NOMINAL POWER
NOMINAL CURRENT NOMINAL POWER 5.0 A 5.0 A
5.0 A 60W 60W
60W 4.0A3.0A2.0A 4.0A3.0A2.0A
4.0A3.0A2.0A 72W72W72W 72W72W72W
72W72W72W 1.5 A 1.5 A
1.5 A 72W 72W
72WCURRENT ADJ. RANGE of CURRENT ADJ. RANGE of
CURRENT ADJ. RANGE of Can be adjusted by internal potentiometer Can be adjusted by internal potentiometer
Can be adjusted by the inner potentiometerOUTPUT OUTPUT
OUTPUT 3 ~ 5A 3 ~ 5A
3 ~ 5A RIPPLE & NOISE (max.) Note.2150mVp-p RIPPLE & NOISE (max.) Note.2150mVp-p
RIPPLE & NOISE (max.) Note.2150mVp-p 2.4 ~ 4A1.8 ~ 3A1.2 ~ 2A 2.4 ~ 4A1.8 ~ 3A1.2 ~ 2A
2.4 ~ 4A1.8 ~ 3A1.2 ~ 2A 200mVp-p200mVp-p200mVp-p 200mVp-p200mVp-p200mVp-p
200mVp-p200mVp-p200mVp-p 0.9 ~ 1.5 to 0.9 ~ 1.5 to
0.9 ~ 1.5 to 200mVp-p 200mVp-p
200mVp-p VOLTAGE TOLERANCE Note.32.5% VOLTAGE TOLERANCE Note.32.5%
VOLTAGE TOLERANCE Note.32.5% 2.0% 2.0%
2.0% 1.0% 1.0%
1.0% 1.0% 1.0%
1.0% 1.0% 1.0%
1.0% LINE REGULATION LOAD REGULATION LINE REGULATION LOAD REGULATION
LINE REGULATION LOAD REGULATION 0.5% 0.5%
0.5% 2.0% 2.0%
2.0% 0.5% 0.5%
0.5% 1.5% 1.5%
1.5% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% 0.5% 0.5%
0.5% SETUP, RISE TIME Note.72000ms,80ms / 115VAC 500ms,80ms / 230VAC at full load SETUP, RISE TIME Note.72000ms,80ms / 115VAC 500ms,80ms / 230VAC at full load
SETUP, RISE TIME Note.72000ms,80ms / 115VAC 500ms,80ms / 230VAC at full load KEEP THE TIME OF KEEP THE TIME OF
KEEP THE TIME OF 16ms at full load230VAC/115VAC 16ms at full load230VAC/115VAC
16ms at full load230VAC/115VAC VOLTAGE RANGENote.490 ~ 305VAC127~431VDC VOLTAGE RANGENote.490 ~ 305VAC127~431VDC
VOLTAGE RANGENote.490 ~ 305VAC127~431VDC FREQUENCY RANGE POWER FACTOR(Typ.) FREQUENCY RANGE POWER FACTOR(Typ.)
FREQUENCY RANGE POWER FACTOR(Typ.) TOTAL HARMONIC DISTORTION TOTAL HARMONIC DISTORTION
TOTAL HARMONIC DISTORTION 47 ~ 63Hz 47 ~ 63Hz
47 ~ 63Hz PF0.96/115VAC, PF0.96/230VAC,PF>0.92/277VAC at full load(please refer to "Power Factor characteristic curve"), THD< 20% when output loading65% at 115VAC/230VAC input and output loading75% at 277VAC input PF0.96/115VAC, PF0.96/230VAC,PF>0.92/277VAC at full load(please refer to "Power Factor characteristic curve"), THD< 20% when output loading65% at 115VAC/230VAC input and output loading75% at 277VAC input
PF0.96/115VAC, PF0.96/230VAC,PF>0.92/277VAC at full load(please refer to "Power Factor characteristic curve"), THD< 20% when output loading65% at 115VAC/230VAC input and output loading75% at 277VAC input INPUT INPUT
INPUT EFFICIENCY(Typ.) EFFICIENCY(Typ.)
EFFICIENCY(Typ.) 88% 88%
88% 89%89%90% 90% 89%89%90% 90%
89%89%90% 90% AC POWER AC POWER
AC POWER INRUSH CURRENT(Typ.) MAX. No. of the systems of power in the 16TH INRUSH CURRENT(Typ.) MAX. No. of the systems of power in the 16TH
INRUSH CURRENT(Typ.) MAX. No. of the systems of power in the 16TH CIRCUIT BREAKER CIRCUIT BREAKER
CIRCUIT BREAKER The LEAKAGE CURRENT of the Note.5 The LEAKAGE CURRENT of the Note.5
The LEAKAGE CURRENT of the Note.5 0.85 A/115VAC 0.425 A/230VAC0.4A/277VAC 0.85 A/115VAC 0.425 A/230VAC0.4A/277VAC
0.85 A/115VAC 0.425 A/230VAC0.4A/277VAC COLD start 55A(twidth=340 measured at 50% Ipeak) at 230VAC COLD start 55A(twidth=340 measured at 50% Ipeak) at 230VAC
COLD start 55A(twidth=340 measured at 50% Ipeak) at 230VAC6 units (circuit breaker type B) / 11 units (circuit breaker type C) 230VAC 6 units (circuit breaker type B) / 11 units (circuit breaker type C) 230VAC
6 units (circuit breaker type B) / 11 units (circuit breaker type C) at 230vac<0.75 mA / 277VAC <0.75 mA / 277VAC
<0.75 mA / 277VAC 95 ~ 108% 95 ~ 108%
95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed Protection type : Constant current limiting, recovers automatically after fault condition is removed
Protection type : Constant current limiting, recovers automatically after fault condition is removed SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed. SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed.
SHORT CIRCUIT Protection type : Hiccup mode, recovers automatically after fault condition is removed.PROTECTION PROTECTION
PROTECTIONOVER VOLTAGE OVER VOLTAGE
OVER VOLTAGE 14 ~ 17V 14 ~ 17V
14 ~ 17V 21 ~ 25V 28 ~ 34V41 ~ 48V 54 ~ 63V 21 ~ 25V 28 ~ 34V41 ~ 48V 54 ~ 63V
21 ~ 25V 28 ~ 34V41 ~ 48V 54 ~ 63VENVIRONMENT ENVIRONMENT
ENVIRONMENT SAFETY AND EMC SAFETY AND EMC
SECURITY AND EMCOTHERS OTHER
OTHERSOVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY THE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY
THE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., THE HUMIDITY TEMP. COEFFICIENT VIBRATION STORAGE TEMP., THE HUMIDITY TEMP. COEFFICIENT VIBRATION
STORAGE TEMP., THE HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION
SAFETY STANDARDS VOLTAGE RESISTANCE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTBF DIMENSION EMC IMMUNITY MTBF DIMENSION
EMC IMMUNITY MTBF DIMENSION PACKAGING PACKAGING
PACKAGING Protection type : Shut down o/p voltage, re-power on to recover Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover
Shut down o/p voltage, re-power on to recover -40 ~ +70(Refer to "Reduction Curve") -40 ~ +70(Refer to "Reduction Curve")
-40 ~ +70(Refer to "Reduction Curve") 20 ~ 95% RH non-condensing 20 ~ 95% RH non-condensing
20 ~ 95% RH non-condensing -40 ~ +80, 10 ~ 95% RH -40 ~ +80, 10 ~ 95% RH
-40 ~ +80, 10 ~ 95% RH 0.03%/ (0 ~ 50) 0.03%/ (0 ~ 50)
0.03%/ (0 ~ 50) 10 ~ 500 hz, 5 G, 10 min./1cycle, period for 60 min. each along X, y, Z axes 10 ~ 500 hz, 5 G, 10 min./1cycle, period for 60 min. each along X, y, Z axes
10 ~ 500 hz, 5 G, 10 min./1cycle, period for 60 min. each along X, y, Z axes GB19510.14, GB19510.1, IP65 approved; design refer to TUV EN61347-1, EN61347-2-13, UL8750 GB19510.14, GB19510.1, IP65 approved; design refer to TUV EN61347-1, EN61347-2-13, UL8750
GB19510.14, GB19510.1, IP65 approved; design refer to TUV EN61347-1, EN61347-2-13, UL8750 I/P-O/P:3.75 KVAC I/P-FG:2KVAC O/P-FG:0.5 KVAC I/P-O/P:3.75 KVAC I/P-FG:2KVAC O/P-FG:0.5 KVAC
I/P-O/P:3.75 KVAC I/P-FG:2KVAC O/P-FG:0.5 KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25/ 70% RH I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25/ 70% RH Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C(65% load);EN61000-3-3 Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C(65% load);EN61000-3-3
Compliance to EN55015, GB17743, GB17625.1, EN61000-3-2 Class C(65% load);EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 4KV), criteria A 338.2 Khrs min.MIL-HDBK-217F (25) 338.2 Khrs min.MIL-HDBK-217F (25)
338.2 Khrs min.MIL-HDBK-217F (25) 127.2*90*38.8 mm (L*W*H) 127.2*90*38.8 mm (L*W*H)
127.2*90*38.8 mm (L*W*H) 0.76 Kg;16pcs/ 13.2 Kgs/0.77 CUFT 0.76 Kg;16pcs/ 13.2 Kgs/0.77 CUFT
0.76 Kg;16pcs/ 13.2 Kg/0.77 CUFTNOTE NOTE
NOTE 1. All the parameters are NOT speciallymentioned are measured at 230vac input, rated load and 25 ° C ambient temperature. 1. All the parameters are NOT speciallymentioned are measured at 230vac input, rated load and 25 ° C ambient temperature.
1. All the parameters are NOT speciallymentioned are measured at 230vac input, rated load and 25 ° C ambient temperature. 2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminatedwith a 0.1 uf and 47uf capacitor in parallel. 2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminatedwith a 0.1 uf and 47uf capacitor in parallel.
2. Curly and noiseare measured at 20 mhz of bandwidth by using a 12" twisted pair-wire terminatedwith a 0.1 uf and 47uf capacitor in parallel. 3. Tolerance : includes setup tolerance, line regulation and load regulation. 3. Tolerance : includes setup tolerance, line regulation and load regulation.
3. Tolerance : includes setup tolerance, line regulation and load regulation. 4. Deratingmay be necessary underlow input voltage,please checkthe static characteristics for more details. 4. Deratingmay be necessary underlow input voltage,please checkthe static characteristics for more details.
4. Deratingmay be necessary underlow input voltage,please checkthe static characteristics for more details. 5. Constant currentoperation region is within 65% >100%nominal outputvoltage.This is the suitable operation region for LED relatedapplications, but please reconfirm special electricalrequirements for some specific system design. 5. Constant currentoperation region is within 65% >100%nominal outputvoltage.This is the suitable operation region for LED relatedapplications, but please reconfirm special electricalrequirements for some specific system design.
5. Constant currentoperation region is within 65% >100%nominal outputvoltage.This is the suitable operation region for LED relatedapplications, but please reconfirm special electricalrequirements for some specific system design. 6. The supply is considered a component which will be operated in combination with final equipment. SinceEMC the performance will be affectedby the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain. 6. The supply is considered a component which will be operated in combination with final equipment. SinceEMC the performance will be affectedby the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain.
6. The supply is considered a component which will be operated in combination with final equipment. SinceEMC the performance will be affectedby the complete installation,the final equipment manufacturers must re-qualify EMC Directive on the complete installationagain. 7. Lengthof setting time is measured at cold first start.Turn on/OFF the supply can lead to the increase of the setup time. 7. Lengthof setting time is measured at cold first start.Turn on/OFF the supply can lead to the increase of the setup time.
7. Lengthof setting time is measured at cold first start.Turn on/OFF the supply can lead to the increase of the setup time. a.To comply with the requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently a.To comply with the requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently
a.To comply with the requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the electrical grid. connected to the electrical grid.
connected to the electrical grid.File name:HSG-70-SPEC2015-11-02 File name:HSG-70-SPEC2015-11-02
File name:HSG-70-SPEC2015-11-02

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.