HRP-200-36 HRP20036 MEANWELL Input: 85-264 AC / 120-370 DC, Output: 1, V1: 36, A1: 5,7 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

HRP-200-36 HRP20036 MEANWELL Input: 85-264 AC / 120-370 DC, Output: 1, V1: 36, A1: 5,7

HRP-200-36

HRP20036

MEANWELL

Available

Ship on today

Input: 85-264 AC / 120-370 DC, Output: 1, V1: 36, A1: 5,7

More details


Power Supplies

G6

HRP

* Brand new produt in its original packing covered by the warranties and certifications provided by MEANWELL

QuantityPrice
1+$80.47
4+$75.55
7+$74.07
10+$73.25
14+$72.60
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



2 0 0 W S i n g l e O u t p u t w i t h P F C F u n ct i o n 2 0 0 W S i n g l e O u t p u t w i t h P F C F u n ct i o n
2 0 0 W S i n g l e O u t p u t w i t h P F C F u n ct i o n H R P - 2 0 0 s e r i e s H R P - 2 0 0 s e r i e s
H R P - 2 0 0 s e r i e s Features : Features :
Features : Universal AC input / Full range Universal AC input / Full range
Universal AC input / Full range Built-in active PFC function, PF>0.95 Built-in active PFC function, PF>0.95
Built-in active PFC function, PF>0.95 High efficiency up to 89% High efficiency up to 89%
High efficiency up to 89% Withstand 300VAC surge input for 5 seconds Withstand 300VAC surge input for 5 seconds
Withstand 300VAC surge input for 5 seconds Protections: Short circuit / Overload/ Over voltage/ Over temperature Protections: Short circuit / Overload/ Over voltage/ Over temperature
Protections: Short circuit / Overload/ Over voltage/ Over temperature Cooling by free air convection Cooling by free air convection
Cooling by free air convection Built-in constant currentlimiting circuit Built-in constant currentlimiting circuit
Built-in constant currentlimiting circuit 1U low profile 38mm 1U low profile 38mm
1U low profile 38mm Built-in remotesense function Built-in remotesense function
Built-in remotesense function 5 years warranty 5 years warranty
5 years warrantySPECIFICATION SPECIFICATION
SPECIFICATION MODEL MODEL
MODEL DC VOLTAGE RATED CURRENT CURRENT RANGE DC VOLTAGE RATED CURRENT CURRENT RANGE
DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RATED POWER
RATED POWER HRP-200-3.3 HRP-200-5HRP-200-7.5 HRP-200-12HRP-200-15HRP-200-24HRP-200-36HRP-200-48 HRP-200-3.3 HRP-200-5HRP-200-7.5 HRP-200-12HRP-200-15HRP-200-24HRP-200-36HRP-200-48
HRP-200-3.3 HRP-200-5HRP-200-7.5 HRP-200-12HRP-200-15HRP-200-24HRP-200-36HRP-200-48 3.3V 5V7.5V 12V15V24V36V48V 3.3V 5V7.5V 12V15V24V36V48V
3.3V 5V7.5V 12V15V24V36V48V 40A35A26.7A 16.7A 13.4A 8.4A 5.7A 4.3A 40A35A26.7A 16.7A 13.4A 8.4A 5.7A 4.3A
40A35A26.7A 16.7A 13.4A 8.4A 5.7A 4.3A 0 ~ 40A0 ~ 35A0 ~ 26.7A 0 ~ 16.7A 0 ~ 13.4A 0 ~ 8.4A 0 ~ 5.7A 0 ~ 4.3A 0 ~ 40A0 ~ 35A0 ~ 26.7A 0 ~ 16.7A 0 ~ 13.4A 0 ~ 8.4A 0 ~ 5.7A 0 ~ 4.3A
0 ~ 40A0 ~ 35A0 ~ 26.7A 0 ~ 16.7A 0 ~ 13.4A 0 ~ 8.4A 0 ~ 5.7A 0 ~ 4.3A 132W 175W 200.3W200.4W201W 201.6W205.2W206.4W 132W 175W 200.3W200.4W201W 201.6W205.2W206.4W
132W 175W 200.3W200.4W201W 201.6W205.2W206.4W RIPPLE & NOISE (max.)No te.280mVp-p90mVp-p100mVp-p120mVp-p150mVp-p150mVp-p250mVp-p250mVp-p RIPPLE & NOISE (max.)No te.280mVp-p90mVp-p100mVp-p120mVp-p150mVp-p150mVp-p250mVp-p250mVp-p
RIPPLE & NOISE (max.)No te.280mVp-p90mVp-p100mVp-p120mVp-p150mVp-p150mVp-p250mVp-p250mVp-p OUTPUTVOLTAGE ADJ. RANGE OUTPUTVOLTAGE ADJ. RANGE
OUTPUTVOLTAGE ADJ. RANGE 2.8 ~ 3.8V4.3 ~ 5.8V6.8 ~ 9V 10.2 ~ 13.8V13.5 ~ 18V 21.6 ~ 28.8V28.8 ~ 39.6V40.8 ~ 55.2V 2.8 ~ 3.8V4.3 ~ 5.8V6.8 ~ 9V 10.2 ~ 13.8V13.5 ~ 18V 21.6 ~ 28.8V28.8 ~ 39.6V40.8 ~ 55.2V
2.8 ~ 3.8V4.3 ~ 5.8V6.8 ~ 9V 10.2 ~ 13.8V13.5 ~ 18V 21.6 ~ 28.8V28.8 ~ 39.6V40.8 ~ 55.2V VOLTAGE TO LERANCE Note.3 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% VOLTAGE TO LERANCE Note.3 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0%
VOLTAGE TO LERANCE Note.3 2.0% 2.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.)
LINE REGULATION LOAD REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% 0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2%
0.5% 0.5% 0.5% 0.3% 0.3% 0.2% 0.2% 0.2% 1.5% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 1.5% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5%
1.5% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 1 00 0 ms , 50m s/ 2 30 VAC 25 0 0m s, 50 m s/ 11 5 VA C at fu ll loa d 1 00 0 ms , 50m s/ 2 30 VAC 25 0 0m s, 50 m s/ 11 5 VA C at fu ll loa d
1 00 0 ms , 50m s/ 2 30 VAC 25 0 0m s, 50 m s/ 11 5 VA C at fu ll loa d 1 6m s/ 2 30 VAC 16 m s/ 115 VAC at fu ll lo ad 1 6m s/ 2 30 VAC 16 m s/ 115 VAC at fu ll lo ad
1 6m s/ 2 30 VAC 16 m s/ 115 VAC at fu ll lo ad VOLTAGE RANGENote.5 8 5 ~ 264 VAC120 ~ 3 70 VDC VOLTAGE RANGENote.5 8 5 ~ 264 VAC120 ~ 3 70 VDC
VOLTAGE RANGENote.5 8 5 ~ 264 VAC120 ~ 3 70 VDC FR EQUENCY RANGE POWER FACTOR (Typ.) FR EQUENCY RANGE POWER FACTOR (Typ.)
FR EQUENCY RANGE POWER FACTOR (Typ.) 4 7 ~ 63Hz 4 7 ~ 63Hz
4 7 ~ 63Hz P F>0 .9 5 /2 30 VACPF>0 .9 9 /115VAC a t f ull lo a d P F>0 .9 5 /2 30 VACPF>0 .9 9 /115VAC a t f ull lo a d
P F>0 .9 5 /2 30 VACPF>0 .9 9 /115VAC a t f ull lo a d INPUT INPUT
INPUT EFF ICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT EFF ICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT
EFF ICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENTOVERLOA D OVERLOA D
OVERLOA D 80%84% 80%84%
80%84% 2 .1 A/ 115 VAC1. 1 A/ 23 0 VA C 2 .1 A/ 115 VAC1. 1 A/ 23 0 VA C
2 .1 A/ 115 VAC1. 1 A/ 23 0 VA C 3 5A /115 VA C 7 0 A/ 2 30 VAC 3 5A /115 VA C 7 0 A/ 2 30 VAC
3 5A /115 VA C 7 0 A/ 2 30 VAC <1 . 2m A / 240 VAC <1 . 2m A / 240 VAC
<1 . 2m A / 240 VAC 1 05 ~ 13 5 % r at e d out p ut po wer 1 05 ~ 13 5 % r at e d out p ut po wer
1 05 ~ 13 5 % r at e d out p ut po wer 86%88%88%88%89%89% 86%88%88%88%89%89%
86%88%88%88%89%89% P ro t ec tio n typ e : Co n sta n t cu rre nt l imi tin g , re cov ers a u to m at ica lly a ft er f au lt c on d itio n i s re m o ve d P ro t ec tio n typ e : Co n sta n t cu rre nt l imi tin g , re cov ers a u to m at ica lly a ft er f au lt c on d itio n i s re m o ve d
P ro t ec tio n typ e : Co n sta n t cu rre nt l imi tin g , re cov ers a u to m at ica lly a ft er f au lt c on d itio n i s re m o ve d PROTECTION PROTECTION
PROTECTIONOVER VOLTAGE OVER VOLTAGE
OVER VOLTAGE 3.96 ~ 4.62V 3.96 ~ 4.62V
3.96 ~ 4.62V 6 ~ 7V9.4 ~ 10.9V14.4 ~ 16.8V18.8 ~ 21.8V30 ~ 34.8V 41.4 ~ 48.6V57.6 ~ 67.2V 6 ~ 7V9.4 ~ 10.9V14.4 ~ 16.8V18.8 ~ 21.8V30 ~ 34.8V 41.4 ~ 48.6V57.6 ~ 67.2V
6 ~ 7V9.4 ~ 10.9V14.4 ~ 16.8V18.8 ~ 21.8V30 ~ 34.8V 41.4 ~ 48.6V57.6 ~ 67.2V ENVIRONMENT ENVIRONMENT
ENVIRONMENT SAFETY & EMC SAFETY & EMC
SAFETY & EMC (Note 4) (Note 4)
(Note 4)OTHERS OTHERS
OTHERSOVER TEMPERATURE WORKI NG TE MP. WORKI NG HUMIDITY OVER TEMPERATURE WORKI NG TE MP. WORKI NG HUMIDITY
OVER TEMPERATURE WORKI NG TE MP. WORKI NG HUMIDITY STORAGE TEMP., HUMI DITY STORAGE TEMP., HUMI DITY
STORAGE TEMP., HUMI DITY TEMP. COEFFICIENT VIBRATION TEMP. COEFFICIENT VIBRATION
TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY MTB F DIMENSION EMC IMMUNITY MTB F DIMENSION
EMC IMMUNITY MTB F DIMENSION PACKING PACKING
PACKING P ro t ec tio n typ e : Sh ut do wn o/p vo lta g e, re-p o we r on to rec ov er P ro t ec tio n typ e : Sh ut do wn o/p vo lta g e, re-p o we r on to rec ov er
P ro t ec tio n typ e : Sh ut do wn o/p vo lta g e, re-p o we r on to rec ov er S hu t down o/ p v olt a ge , re co ve rs au to m a tica lly a f te r t e mp e rat u re goe s d own S hu t down o/ p v olt a ge , re co ve rs au to m a tica lly a f te r t e mp e rat u re goe s d own
S hu t down o/ p v olt a ge , re co ve rs au to m a tica lly a f te r t e mp e rat u re goe s d own -4 0 ~ +7 0 (Ref e r t o "Dera ti ng Curve " ) -4 0 ~ +7 0 (Ref e r t o "Dera ti ng Curve " )
-4 0 ~ +7 0 (Ref e r t o "Dera ti ng Curve " ) 2 0 ~ 90% R H n on -co n de n sin g 2 0 ~ 90% R H n on -co n de n sin g
2 0 ~ 90% R H n on -co n de n sin g -4 0 ~ +8 5, 10 ~ 95% R H -4 0 ~ +8 5, 10 ~ 95% R H
-4 0 ~ +8 5, 10 ~ 95% R H 0.03%/ (0 ~ 50) 0.03%/ (0 ~ 50)
0.03%/ (0 ~ 50) 1 0 ~ 500 Hz, 5G 1 0 mi n. /1 cyc le , 60 m in . eac h alon g X , Y, Z a xe s 1 0 ~ 500 Hz, 5G 1 0 mi n. /1 cyc le , 60 m in . eac h alon g X , Y, Z a xe s
1 0 ~ 500 Hz, 5G 1 0 mi n. /1 cyc le , 60 m in . eac h alon g X , Y, Z a xe s UL 60 9 50 -1 , TUV EN6 09 5 0-1 ap p rov ed UL 60 9 50 -1 , TUV EN6 09 5 0-1 ap p rov ed
UL 60 9 50 -1 , TUV EN6 09 5 0-1 ap p rov ed I /P -O/P : 3K VA C I/P -FG: 2K VA C O/ P-FG :0 . 5K VA C I /P -O/P : 3K VA C I/P -FG: 2K VA C O/ P-FG :0 . 5K VA C
I /P -O/P : 3K VA C I/P -FG: 2K VA C O/ P-FG :0 . 5K VA C I /P -O/P, I /P -FG, O /P -FG: 10 0 M Oh m s / 5 00 V DC / 2 5/ 70% R H Co mp lia n ce to E N55 0 22 (CIS PR2 2) Cla ss B, EN6 10 0 0 -3 -2 ,-3 I /P -O/P, I /P -FG, O /P -FG: 10 0 M Oh m s / 5 00 V DC / 2 5/ 70% R H Co mp lia n ce to E N55 0 22 (CIS PR2 2) Cla ss B, EN6 10 0 0 -3 -2 ,-3
I /P -O/P, I /P -FG, O /P -FG: 10 0 M Oh m s / 5 00 V DC / 2 5/ 70% R H Co mp lia n ce to E N55 0 22 (CIS PR2 2) Cla ss B, EN6 10 0 0 -3 -2 ,-3 Co mp lia n ce to E N61 0 00 -4 -2, 3, 4 ,5 ,6 , 8, 11, EN5 50 2 4, he a vy in du st ry lev el , crit eri a A Co mp lia n ce to E N61 0 00 -4 -2, 3, 4 ,5 ,6 , 8, 11, EN5 50 2 4, he a vy in du st ry lev el , crit eri a A
Co mp lia n ce to E N61 0 00 -4 -2, 3, 4 ,5 ,6 , 8, 11, EN5 50 2 4, he a vy in du st ry lev el , crit eri a A 2 09 . 4K h rs m in . MI L-HDB K-2 1 7F ( 2 5) 2 09 . 4K h rs m in . MI L-HDB K-2 1 7F ( 2 5)
2 09 . 4K h rs m in . MI L-HDB K-2 1 7F ( 2 5) 1 99 *9 8 *3 8m m (L* W* H) 1 99 *9 8 *3 8m m (L* W* H)
1 99 *9 8 *3 8m m (L* W* H) 0.77Kg; 18pcs/14.9Kg/0.9CUFT 0.77Kg; 18pcs/14.9Kg/0.9CUFT
0.77Kg; 18pcs/14.9Kg/0.9CUFTNOTE NOTE
NOTE 1. All parameters NOT specially mentioned aremeasured at 230VAC input, ratedload and25 of ambient temperature. 1. All parameters NOT specially mentioned aremeasured at 230VAC input, ratedload and25 of ambient temperature.
1. All parameters NOT specially mentioned aremeasured at 230VAC input, ratedload and25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidthby using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 2. Ripple & noise are measured at 20MHz of bandwidthby using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
2. Ripple & noise are measured at 20MHz of bandwidthby using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulationandload regulation. 3. Tolerance : includes set up tolerance, line regulationandload regulation.
3. Tolerance : includes set up tolerance, line regulationandload regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com)
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies. (as available on http://www.meanwell.com) 5. Deratingmay be needed underlow input voltages. Please checkthe derating curve for more details. 5. Deratingmay be needed underlow input voltages. Please checkthe derating curve for more details.
5. Deratingmay be needed underlow input voltages. Please checkthe derating curve for more details. F il e Na me:HRP-2 00 -SP EC20 1 4-0 7-0 7 F il e Na me:HRP-2 00 -SP EC20 1 4-0 7-0 7
F il e Na me:HRP-2 00 -SP EC20 1 4-0 7-0 7

Datasheet - PDF

Title:Language:Size:Type:
pdf-Input: 85-264 AC / 120-370 DC, Output: 1, V1: 36, A1: 5,7 - MEANWELL - HRP-200-36 - HRP20036English220 Kbytespdf-Input: 85-264 AC / 120-370 DC, Output: 1, V1: 36, A1: 5,7 - MEANWELL - HRP-200-36 - HRP20036