PB-300N-48 PB300N48 MEANWELL Input: 90-132 AC / 180-264 AC, Output: 1, V1: 57,6, A1: 3,2 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

PB-300N-48 PB300N48 MEANWELL Input: 90-132 AC / 180-264 AC, Output: 1, V1: 57,6, A1: 3,2

PB-300N-48

PB300N48

MEANWELL

Available

Ship on today

Input: 90-132 AC / 180-264 AC, Output: 1, V1: 57,6, A1: 3,2

More details


Power Supplies

CHARGERS

PB

* Brand new produt in its original packing covered by the warranties and certifications provided by MEANWELL

QuantityPrice
1+$93.68
3+$89.14
6+$86.95
9+$85.87
12+$85.24
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



300W Single Output Battery ChargerPB-300series 300W Single Output Battery ChargerPB-300series
300W Single Output Battery ChargerPB-300series Features : Features :
Features : Charger for lead-acidbatteries(flooded,Gel and AGM) and Li-ion batteries Charger for lead-acidbatteries(flooded,Gel and AGM) and Li-ion batteries
Charger for lead-acidbatteries(flooded,Gel and AGM) and Li-ion batteries (lithiumiron and lithiummanganese) (Note.1) (lithiumiron and lithiummanganese) (Note.1)
(lithiumiron and lithiummanganese) (Note.1) 2 stagecharging characteristic 2 stagecharging characteristic
2 stagecharging characteristic 3 stagecharging 3 stagecharging
3 stagecharging AC 115/230VAC selected by switch AC 115/230VAC selected by switch
AC 115/230VAC selected by switch Built-in passivePFC functioncompliance to EN61000-3-2 Class A (option) Built-in passivePFC functioncompliance to EN61000-3-2 Class A (option)
Built-in passivePFC functioncompliance to EN61000-3-2 Class A (option) Protection: Short circuit/ Reversepolarity/ Over voltage/ Over temperature Protection: Short circuit/ Reversepolarity/ Over voltage/ Over temperature
Protection: Short circuit/ Reversepolarity/ Over voltage/ Over temperature Cooling by free air convection Cooling by free air convection
Cooling by free air convection 2 color LED loading indicator 2 color LED loading indicator
2 color LED loading indicator Low cost, High reliability Low cost, High reliability
Low cost, High reliability 3 years warranty 3 years warranty
3 years warrantyP:With Passive PFC N:Without Passive PFC P:With Passive PFC N:Without Passive PFC
P:With Passive PFC N:Without Passive PFC
PB 300P 12 PB 300P 12
PB 300P 12 12:14.4V 12:14.4V
12:14.4V 24:28.8V 24:28.8V
24:28.8V 48:57.6V 48:57.6V
48:57.6V (except for 48V) (except for 48V)
(except for 48V) (P type only) (P type only)
(P type only) SPECIFICATION SPECIFICATION
SPECIFICATION MODEL MODEL
MODELPB-300-12 PB-300-12
PB-300-12PB-300-24 PB-300-24
PB-300-24PB-300-48 PB-300-48
PB-300-48 BOOST CHARGEVOLTAGE Vboost 14.4V 28.8V BOOST CHARGEVOLTAGE Vboost 14.4V 28.8V
BOOST CHARGEVOLTAGE Vboost 14.4V 28.8V 57.6V 57.6V
57.6VOUTPUT OUTPUT
OUTPUT FLOAT CHARGEVOLTAGE Vfloat 13.6V FLOAT CHARGEVOLTAGE Vfloat 13.6V
FLOAT CHARGEVOLTAGE Vfloat 13.6V VOLTAGE ADJUSTABLE RANGE 13 ~ 14.7V VOLTAGE ADJUSTABLE RANGE 13 ~ 14.7V
VOLTAGE ADJUSTABLE RANGE 13 ~ 14.7V RECOMMENDED BATTERY RECOMMENDED BATTERY
RECOMMENDED BATTERY 60 ~ 200Ah 60 ~ 200Ah
60 ~ 200Ah CAPACITY(AMP HOURS) Note 6 CAPACITY(AMP HOURS) Note 6
CAPACITY(AMP HOURS) Note 6 27.2V 27.2V
27.2V 26 ~ 28.8V 26 ~ 28.8V
26 ~ 28.8V30 ~ 100Ah 30 ~ 100Ah
30 ~ 100Ah 54.4V 54.4V
54.4V 52 ~ 58.6V 52 ~ 58.6V
52 ~ 58.6V15 ~ 50Ah 15 ~ 50Ah
15 ~ 50Ah BATTERY TYPE BATTERY TYPE
BATTERY TYPE Open & Sealed Lead Acid Open & Sealed Lead Acid
Open & Sealed Lead Acid MAX. OUTPUT CURRENT(Typ.) Note 820.85A MAX. OUTPUT CURRENT(Typ.) Note 820.85A
MAX. OUTPUT CURRENT(Typ.) Note 820.85A CONTINUOUS OUTPUT CONTINUOUS OUTPUT
CONTINUOUS OUTPUT 10.5A 10.5A
10.5A 5.3A 5.3A
5.3A CURRENT (Typ.)Note 7 CURRENT (Typ.)Note 7
CURRENT (Typ.)Note 7 12.5A 12.5A
12.5A 6.25A 6.25A
6.25A 3.2A 3.2A
3.2A VOLTAGE RANGE FREQUENCY RANGE VOLTAGE RANGE FREQUENCY RANGE
VOLTAGE RANGE FREQUENCY RANGE 90 ~ 132VAC / 180 ~ 264VAC selected by switch 127 ~ 187VDC / 254 ~ 370VDC 90 ~ 132VAC / 180 ~ 264VAC selected by switch 127 ~ 187VDC / 254 ~ 370VDC
90 ~ 132VAC / 180 ~ 264VAC selected by switch 127 ~ 187VDC / 254 ~ 370VDC 47 ~ 63Hz 47 ~ 63Hz
47 ~ 63Hz POWER FACTOR (Typ.) >0.65 (with P type) at 230VAC POWER FACTOR (Typ.) >0.65 (with P type) at 230VAC
POWER FACTOR (Typ.) >0.65 (with P type) at 230VAC INPUT INPUT
INPUT EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.)
EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT LEAKAGE CURRENT
LEAKAGE CURRENT 85% 85%
85% 6A/115VAC3A/230VAC COLD START 60A 6A/115VAC3A/230VAC COLD START 60A
6A/115VAC3A/230VAC COLD START 60A <3.5mA / 240VAC <3.5mA / 240VAC
<3.5mA / 240VAC 86% 86%
86% 88% 88%
88% SHORT CIRCUIT REVERSE POLARITY SHORT CIRCUIT REVERSE POLARITY
SHORT CIRCUIT REVERSE POLARITY O/P Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on O/P Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on
O/P Built in fuse (FS100) to protect short circuit condition, shut down o/p voltage and can not re-power on By internal fuse By internal fuse
By internal fuse PROTECTION FUNCTION PROTECTION FUNCTION
PROTECTION FUNCTION ENVIRONMENT ENVIRONMENT
ENVIRONMENTSAFETY & EMC SAFETY & EMC
SAFETY & EMC (Note 5) (Note 5)
(Note 5)OVER VOLTAGE OVER VOLTAGE
OVER VOLTAGEOVER TEMPERATURE REMOTE CONTROL (CN5) WORKING TEMP. WORKING HUMIDITY OVER TEMPERATURE REMOTE CONTROL (CN5) WORKING TEMP. WORKING HUMIDITY
OVER TEMPERATURE REMOTE CONTROL (CN5) WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY STORAGE TEMP., HUMIDITY
STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION TEMP. COEFFICIENT VIBRATION
TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY EMC IMMUNITY
EMC IMMUNITY 16 ~ 18V31 ~ 35V 16 ~ 18V31 ~ 35V
16 ~ 18V31 ~ 35V Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero Open: Normal work Short: Stop Charging Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero Open: Normal work Short: Stop Charging
Protection type : Shut down o/p voltage, re-power on to recover Protection type : Automatically derate charge current until zero Open: Normal work Short: Stop Charging -10 ~ +50 (Refer to "Derating Curve") -10 ~ +50 (Refer to "Derating Curve")
-10 ~ +50 (Refer to "Derating Curve") 20 ~ 90% RH non-condensing 20 ~ 90% RH non-condensing
20 ~ 90% RH non-condensing -40 ~ +85, 10 ~ 95% RH -40 ~ +85, 10 ~ 95% RH
-40 ~ +85, 10 ~ 95% RH 0.05%/ (0 ~ 45) 0.05%/ (0 ~ 45)
0.05%/ (0 ~ 45) 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes IEC60335-2-29 CB approved by TUV(except for 48V), UL60950-1 approved IEC60335-2-29 CB approved by TUV(except for 48V), UL60950-1 approved
IEC60335-2-29 CB approved by TUV(except for 48V), UL60950-1 approved I/P-O/P:3KVAC I/P-FG:2KVACO/P-FG:0.5KVAC I/P-O/P:3KVAC I/P-FG:2KVACO/P-FG:0.5KVAC
I/P-O/P:3KVAC I/P-FG:2KVACO/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 (only P type) Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 (only P type)
Compliance to EN55022 (CISPR22) Class B, EN61000-3-2,-3 (only P type) Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,criteria A Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level,criteria A 59 ~ 64V 59 ~ 64V
59 ~ 64V MTBF115.8Khrs min.MIL-HDBK-217F (25) MTBF115.8Khrs min.MIL-HDBK-217F (25)
MTBF115.8Khrs min.MIL-HDBK-217F (25) OTHERS OTHERS
OTHERS DIMENSION DIMENSION
DIMENSION 253*135*48.5mm(L*W*H) 253*135*48.5mm(L*W*H)
253*135*48.5mm(L*W*H) NOTE NOTE
NOTE PACKING 1.45Kg; 6pcs/9.7Kg/0.95CUFT PACKING 1.45Kg; 6pcs/9.7Kg/0.95CUFT
PACKING 1.45Kg; 6pcs/9.7Kg/0.95CUFT 1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details. 1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details.
1. Modification for charger specification may be required for different battery specification. Please contact battery vendor and MEAN WELL for details. 2. All parameters NOT specially mentioned are measured at 230VAC input, ratedload and 25 of ambient temperature. 2. All parameters NOT specially mentioned are measured at 230VAC input, ratedload and 25 of ambient temperature.
2. All parameters NOT specially mentioned are measured at 230VAC input, ratedload and 25 of ambient temperature. 3. Ripple & noiseare measured at 20MHz of bandwidth by usinga 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Ripple & noiseare measured at 20MHz of bandwidth by usinga 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Ripple & noiseare measured at 20MHz of bandwidth by usinga 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 4. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Tolerance : includes set up tolerance, line regulation and load regulation. 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. EMC directives.
EMC directives. 6. This is Mean Well's suggested range. Please consultyour batterymanufacturer for their suggestions aboutmaximumcharging currentlimitation. 6. This is Mean Well's suggested range. Please consultyour batterymanufacturer for their suggestions aboutmaximumcharging currentlimitation.
6. This is Mean Well's suggested range. Please consultyour batterymanufacturer for their suggestions aboutmaximumcharging currentlimitation. 7. Testconditionis at 25, charging currentwill change underdifferent temperature. 7. Testconditionis at 25, charging currentwill change underdifferent temperature.
7. Testconditionis at 25, charging currentwill change underdifferent temperature. 8. Maximum charging currentwill be in the range of @0A110B ratedoutput current. 8. Maximum charging currentwill be in the range of @0A110B ratedoutput current.
8. Maximum charging currentwill be in the range of @0A110B ratedoutput current.File Name:PB-300-SPEC2015-12-15 File Name:PB-300-SPEC2015-12-15
File Name:PB-300-SPEC2015-12-15

Datasheet - PDF

Title:Language:Size:Type:
pdf-Input: 90-132 AC / 180-264 AC, Output: 1, V1: 57,6, A1: 3,2 - MEANWELL - PB-300N-48 - PB300N48English125 Kbytespdf-Input: 90-132 AC / 180-264 AC, Output: 1, V1: 57,6, A1: 3,2 - MEANWELL - PB-300N-48 - PB300N48

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or