220W AC-DC Industrial AdaptorGS220series
220W AC-DC Industrial AdaptorGS220series
220W AC-DC Industrial AdaptorGS220seriesFeatures :
Features :
Features :
Universal AC input / Full range
Universal AC input / Full range
Universal AC input / Full range
Built-in active PFC function
Built-in active PFC function
Built-in active PFC function
Do not load powerconsumptione0.5w
Do not load powerconsumptione0.5w
Do not load powerconsumptione0.5w
The energy efficiencyLevelV
The energy efficiencyLevelV
The energy efficiencyLevelV
To comply with EISA 2007,NRCan,AU/NZ MEPS and the EU's ErP
To comply with EISA 2007,NRCan,AU/NZ MEPS and the EU's ErP
To comply with EISA 2007,NRCan,AU/NZ MEPS and the EU's ErP
3 pole AC inlet IEC320-C14
3 pole AC inlet IEC320-C14
3 pole AC inlet IEC320-C14
Be able to(with earthpin)
Be able to(with earthpin)
Be able to(with earthpin)
Protections: short circuit / Overload / Over voltage / Over temperature
Protections: short circuit / Overload / Over voltage / Over temperature
Protections: short circuit / Overload / Over voltage / Over temperature
Fully enclosed plastic case
Fully enclosed plastic case
Fully enclosed plastic case
LED indicator for power on
LED indicator for power on
LED indicator for power on
2 years warranty
2 years warranty
2 years warranty
SPECIFICATION
SPECIFICATION
SPECIFICATION
ORDER NO.
ORDER NO.
ORDER NO.
SECURITY MODEL NO.
SECURITY MODEL NO.
SECURITY MODEL NO.
GS220A12-R7B
GS220A12-R7B
GS220A12-R7B
GS220A12
GS220A12
GS220A12
GS220A15-R7B
GS220A15-R7B
GS220A15-R7B
GS220A15
GS220A15
GS220A15
GS220A20-R7B
GS220A20-R7B
GS220A20-R7B
GS220A20
GS220A20
GS220A20
(except for 48V)
(except for 48V)
(except for 48V)GS220A24-R7B
GS220A24-R7B
GS220A24-R7B
GS220A24
GS220A24
GS220A24
GS220A48-R7B
GS220A48-R7B
GS220A48-R7B
GS220A48
GS220A48
GS220A48
DC VOLTAGENote.2 12V
DC VOLTAGENote.2 12V
DC VOLTAGENote.2 12V
15V
15V
15V
20V 24V 48V
20V 24V 48V
20V 24V 48V
RATED CURRENT CURRENT RANGE RATED POWER (max.)
RATED CURRENT CURRENT RANGE RATED POWER (max.)
RATED CURRENT CURRENT RANGE RATED POWER (max.)
15A
15A
15A
0 ~ 15A
0 ~ 15A
0 ~ 15A
180W
180W
180W
13.4 A
13.4 A
13.4 A
0 ~ 13.4 A
0 ~ 13.4 A
0 ~ 13.4 A
201W
201W
201W
11 To 9.2A4.6A
11 To 9.2A4.6A
11 To 9.2A4.6A
0 ~ 11A 0 ~ 9.2A0 ~ 4.6 TO
0 ~ 11A 0 ~ 9.2A0 ~ 4.6 TO
0 ~ 11A 0 ~ 9.2A0 ~ 4.6 TO
220W221W221W
220W221W221W
220W221W221WOUTPUT
OUTPUT
OUTPUT
RIPPLE & NOISE (max.) Note.380mVp-p VOLTAGE TOLERANCE Note.4 5.0% LINE REGULATIONNote.51.0%
RIPPLE & NOISE (max.) Note.380mVp-p VOLTAGE TOLERANCE Note.4 5.0% LINE REGULATIONNote.51.0%
RIPPLE & NOISE (max.) Note.380mVp-p VOLTAGE TOLERANCE Note.4 5.0% LINE REGULATIONNote.51.0%
100mVp-p
100mVp-p
100mVp-p
5.0%
5.0%
5.0%
1.0%
1.0%
1.0%
150mVp-p180mVp-p240mVp-p
150mVp-p180mVp-p240mVp-p
150mVp-p180mVp-p240mVp-p
4.0%3.0%2.0%
4.0%3.0%2.0%
4.0%3.0%2.0%
1.0%1.0%1.0%
1.0%1.0%1.0%
1.0%1.0%1.0%
LOAD REGULATION
LOAD REGULATION
LOAD REGULATION
5.0%
5.0%
5.0%
5.0%
5.0%
5.0%
4.0%3.0%2.0%
4.0%3.0%2.0%
4.0%3.0%2.0%
SETUP, RISE TIME Note.62000ms, 20ms / 230VAC2000ms, 20ms / 115VACat full load
SETUP, RISE TIME Note.62000ms, 20ms / 230VAC2000ms, 20ms / 115VACat full load
SETUP, RISE TIME Note.62000ms, 20ms / 230VAC2000ms, 20ms / 115VACat full load
HOLD TIME (Typ.)
HOLD TIME (Typ.)
HOLD TIME (Typ.)
20ms / 230VAC20ms / 115VAC at full load
20ms / 230VAC20ms / 115VAC at full load
20ms / 230VAC20ms / 115VAC at full load
VOLTAGE RANGENote.790 ~ 264VAC 127 ~ 370VDC
VOLTAGE RANGENote.790 ~ 264VAC 127 ~ 370VDC
VOLTAGE RANGENote.790 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE POWER FACTOR (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.)
FREQUENCY RANGE POWER FACTOR (Typ.)
47 ~ 63Hz
47 ~ 63Hz
47 ~ 63Hz
PF>0.91 / 230VAC PF>0.98 / 115VAC at full load
PF>0.91 / 230VAC PF>0.98 / 115VAC at full load
PF>0.91 / 230VAC PF>0.98 / 115VAC at full load
INPUT
INPUT
INPUT
EFFICIENCY (Typ.)
EFFICIENCY (Typ.)
EFFICIENCY (Typ.)
90%
90%
90%
90%
90%
90%
92%93.5% 94.5%
92%93.5% 94.5%
92%93.5% 94.5%
PROTECTION
PROTECTION
PROTECTION
AC CURRENT (Typ.) Input CURRENT (max.) The LEAKAGE CURRENT(max.)
AC CURRENT (Typ.) Input CURRENT (max.) The LEAKAGE CURRENT(max.)
AC CURRENT (Typ.) Input CURRENT (max.) The LEAKAGE CURRENT(max.)The OVERHEAD of
The OVERHEAD of
OVERLOADOVER VOLTAGE
OVER VOLTAGE
OVER VOLTAGE
4A / 115VAC2A / 230VAC
4A / 115VAC2A / 230VAC
4A / 115VAC2A / 230VAC
120A / 230VAC
120A / 230VAC
120A / 230VAC
1.5 mA / 240VAC
1.5 mA / 240VAC
1.5 mA / 240VAC
105 ~ 135%rated output power
105 ~ 135%rated output power
105 ~ 135%rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
105 ~ 135% rated output voltage
105 ~ 135% rated output voltage
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Protection type : Shut down o/p voltage, re-power on to recover
Over TEMPERATURE shut down o/p voltage, recovers automatically after temperature goes down
Over TEMPERATURE shut down o/p voltage, recovers automatically after temperature goes down
Over TEMPERATURE shut down o/p voltage, recovers automatically after temperature goes downENVIRONMENT
ENVIRONMENT
ENVIRONMENT
SAFETY AND EMC
SAFETY AND EMC
SAFETY AND EMC
(Note. 8)
(Note. 8)
(Note. 8)OTHER CONNECTOR
OTHER CONNECTOR
OTHER CONNECTOR
WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
WORKING TEMP. OPERATING HUMIDITY STORAGE TEMPERATURE, HUMIDITY TEMP. COEFFICIENT VIBRATION
SAFETY STANDARDS OF STRESS RESISTANCE INSULATION RESISTANCE
SAFETY STANDARDS OF STRESS RESISTANCE INSULATION RESISTANCE
SAFETY STANDARDS OF STRESS RESISTANCE INSULATION RESISTANCE
EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING
EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING
EMC EMISSION EMC IMMUNITY MTBF DIMENSION PACKING
PLUG
PLUG
PLUG
-30 ~ +60 (Refer to "Reduction Curve")
-30 ~ +60 (Refer to "Reduction Curve")
-30 ~ +60 (Refer to "Reduction Curve")
20% ~ 90% RH non-condensing
20% ~ 90% RH non-condensing
20% ~ 90% RH non-condensing
-40 ~ +85, 10 ~ 95% RH
-40 ~ +85, 10 ~ 95% RH
-40 ~ +85, 10 ~ 95% RH
0.03%/(0~50)
0.03%/(0~50)
0.03%/(0~50)
10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, period for 60 min. each along X, y, Z axes
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved
UL60950-1, CSA C22.2, TUV EN60950-1, BSMI CNS14336, CCC GB4943, PSE J60950-1(except for 48V) approved
I/P-O/P: 3KVAC
I/P-O/P: 3KVAC
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
Compliance to EN55022 class B, EN61000-3-2,3, FCC PART 15 / CISPR22 class B, CNS13438 class B, GB9254, GB17625.1
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
191.3 K hrs min.MIL-HDBK-217F(25 )
191.3 K hrs min.MIL-HDBK-217F(25 )
191.3 K hrs min.MIL-HDBK-217F(25 )
210*85*46 mm (L*W*H)
210*85*46 mm (L*W*H)
210*85*46 mm (L*W*H)
1.1 Kg; 12pcs/14.2 Kg/0.73 CUFT
1.1 Kg; 12pcs/14.2 Kg/0.73 CUFT
1.1 Kg; 12pcs/14.2 Kg/0.73 CUFT
See page 2; Other type available by customer requested
See page 2; Other type available by customer requested
See page 2; Other type available by customer requestedNOTE
NOTE
NOTE
CABLESee page 2; Other type available by customer requested
CABLESee page 2; Other type available by customer requested
CABLESee page 2; Other type available by customer requested
1. All parameters are specified at 230vac input, rated load, 25 70% rh ambient.
1. All parameters are specified at 230vac input, rated load, 25 70% rh ambient.
1. All parameters are specified at 230vac input, rated load, 25 70% rh ambient.
2. DC voltage:The output of voltageset in the point measure by plug terminal & 50% load.
2. DC voltage:The output of voltageset in the point measure by plug terminal & 50% load.
2. DC voltage:The output of voltageset in the point measure by plug terminal & 50% load.
3. Ripple and noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf and capacitor of 47uf.
3. Ripple and noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf and capacitor of 47uf.
3. Ripple and noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1 uf and capacitor of 47uf.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
4. Tolerance: includes set up tolerance, line regulation, load regulation.
5. Line regulation is measured from low line to high line at rated load.
5. Line regulation is measured from low line to high line at rated load.
5. Line regulation is measured from low line to high line at rated load.
6. Lengthof set up time is measured at first cold start. Turn on/OFF the supply may lead to increase of the start-up time.
6. Lengthof set up time is measured at first cold start. Turn on/OFF the supply may lead to increase of the start-up time.
6. Lengthof set up time is measured at first cold start. Turn on/OFF the supply may lead to increase of the start-up time.
7. Deratingmay be necessary underlow of the input voltage.Please checkthe of the curve of reduction of power for more details.
7. Deratingmay be necessary underlow of the input voltage.Please checkthe of the curve of reduction of power for more details.
7. Deratingmay be necessary underlow of the input voltage.Please checkthe of the curve of reduction of power for more details.
8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives. For information on how to perform these EMC tests, please refer to "EMI testingof component powersupplies."
EMC directives. For information on how to perform these EMC tests, please refer to "EMI testingof component powersupplies."
EMC directives. For information on how to perform these EMC tests, please refer to "EMI testingof component powersupplies."
(asavailable in http://www.meanwell.com)
(asavailable in http://www.meanwell.com)
(asavailable in http://www.meanwell.com)
File name:GS220-SPEC2015-06-01
File name:GS220-SPEC2015-06-01
File name:GS220-SPEC2015-06-01