GE12I24-P1J GE12I24P1J MEANWELL Input: 90-264 AC / 135-370 DC, Output: 1, V1: 24, A1: 0,625

GE12I24-P1J

GE12I24P1J

MEANWELL

Available

Ship on today

Input: 90-264 AC / 135-370 DC, Output: 1, V1: 24, A1: 0,625

More details


Power Supplies

ADAPTERS

GE

* Brand new produt in its original packing covered by the warranties and certifications provided by MEANWELL

*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



12W AC-DCInterchangeableIndustrialAdaptor GE12series 12W AC-DCInterchangeableIndustrialAdaptor GE12series
12W AC-DCInterchangeableIndustrialAdaptor GE12series Features : Features :
Features : Interchangeable AC plugs (plug kit sold separately) Interchangeable AC plugs (plug kit sold separately)
Interchangeable AC plugs (plug kit sold separately) Universal AC input / Full range Universal AC input / Full range
Universal AC input / Full range No load power consumptione 0.075W No load power consumptione 0.075W
No load power consumptione 0.075W Energy efficiencyLevel Energy efficiencyLevel
Energy efficiencyLevel Comply with EISA 2007/DoEand EU ErP Comply with EISA 2007/DoEand EU ErP
Comply with EISA 2007/DoEand EU ErP Class II power (withoutearth pin) Class II power (withoutearth pin)
Class II power (withoutearth pin) Protections: Short circuit / Overload / Over voltage Protections: Short circuit / Overload / Over voltage
Protections: Short circuit / Overload / Over voltage Pass LPS Pass LPS
Pass LPS Fullyenclosed plasticcase Fullyenclosed plasticcase
Fullyenclosed plasticcase LED indicator for power on LED indicator for power on
LED indicator for power on 2 years warranty 2 years warranty
2 years warranty Interchangeable AC plug specifically for GE series Interchangeable AC plug specifically for GE series
Interchangeable AC plug specifically for GE series TYPE TYPE
TYPE ORDER NO. ORDER NO.
ORDER NO. SPECIFICATION SPECIFICATION
SPECIFICATION Australian typeU.K type European typeUS type Mix four type Australian typeU.K type European typeUS type Mix four type
Australian typeU.K type European typeUS type Mix four type AC plug-AUAC plug-UK AC plug-EU AC plug-USAC plug-MIX AC plug-AUAC plug-UK AC plug-EU AC plug-USAC plug-MIX
AC plug-AUAC plug-UK AC plug-EU AC plug-USAC plug-MIX POWER SUPPLY MAIN BODY ORDER NO. POWER SUPPLY MAIN BODY ORDER NO.
POWER SUPPLY MAIN BODY ORDER NO. SAFETY MODEL NO. SAFETY MODEL NO.
SAFETY MODEL NO. GE12 I 05-P1J GE12 I 07-P1J GE12 I 09-P1J GE12 I 12-P1J GE12 I 15-P1J GE12 I 18-P1J GE12 I 24-P1J GE12 I 05-P1J GE12 I 07-P1J GE12 I 09-P1J GE12 I 12-P1J GE12 I 15-P1J GE12 I 18-P1J GE12 I 24-P1J
GE12 I 05-P1J GE12 I 07-P1J GE12 I 09-P1J GE12 I 12-P1J GE12 I 15-P1J GE12 I 18-P1J GE12 I 24-P1J GE12 I 05 GE12 I 07 GE12 I 09 GE12 I 12 GE12 I 15 GE12 I 18 GE12 I 24 GE12 I 05 GE12 I 07 GE12 I 09 GE12 I 12 GE12 I 15 GE12 I 18 GE12 I 24
GE12 I 05 GE12 I 07 GE12 I 09 GE12 I 12 GE12 I 15 GE12 I 18 GE12 I 24 DC VOLTAGENote.2 5V DC VOLTAGENote.2 5V
DC VOLTAGENote.2 5V 7.5V 9V 7.5V 9V
7.5V 9V 12V15V 18V24V 12V15V 18V24V
12V15V 18V24V RATED CURRENT CURRENT RANGE RATED CURRENT CURRENT RANGE
RATED CURRENT CURRENT RANGE 2.0A 2.0A
2.0A 0 ~ 2.0A 0 ~ 2.0A
0 ~ 2.0A 1.33A 1.33A
1.33A 0 ~ 1.33A 0 ~ 1.33A
0 ~ 1.33A 1.33A 1.33A
1.33A 0 ~ 1.33A 0 ~ 1.33A
0 ~ 1.33A 1.0A 0.8A 0.83A 0.625A 1.0A 0.8A 0.83A 0.625A
1.0A 0.8A 0.83A 0.625A 0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.83A 0 ~ 0.625A 0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.83A 0 ~ 0.625A
0 ~ 1.0A 0 ~ 0.8A 0 ~ 0.83A 0 ~ 0.625AOUTPUT OUTPUT
OUTPUT RATED POWER RATED POWER
RATED POWER 10W 10W
10W 10W 10W
10W 12W 12W
12W 12W 12W 12W 12W
12W 12W 15W 15W 15W 15W
15W 15W RIPPLE & NOISE (max.) Note.3 50mVp-p RIPPLE & NOISE (max.) Note.3 50mVp-p
RIPPLE & NOISE (max.) Note.3 50mVp-p 75mVp-p 75mVp-p
75mVp-p 100mVp-p 100mVp-p
100mVp-p 120mVp-p150mVp-p180mVp-p240mVp-p 120mVp-p150mVp-p180mVp-p240mVp-p
120mVp-p150mVp-p180mVp-p240mVp-p VOLTAGE TOLERANCE Note.4 5.0% VOLTAGE TOLERANCE Note.4 5.0%
VOLTAGE TOLERANCE Note.4 5.0% 5.0% 5.0%
5.0% 5.0% 5.0%
5.0% 3.0% 3.0%
3.0% 3.0% 3.0%
3.0% 3.0%3.0% 3.0%3.0%
3.0%3.0% LINE REGULATIONNote.51.0%1.0%1.0% LINE REGULATIONNote.51.0%1.0%1.0%
LINE REGULATIONNote.51.0%1.0%1.0% 1.0% 1.0%
1.0% 1.0% 1.0%
1.0% 1.0%1.0% 1.0%1.0%
1.0%1.0% LOAD REGULATIONNote.65.0% LOAD REGULATIONNote.65.0%
LOAD REGULATIONNote.65.0% 5.0% 5.0%
5.0% 5.0% 5.0%
5.0% 3.0% 3.0%
3.0% 3.0% 3.0%
3.0% 3.0%3.0% 3.0%3.0%
3.0%3.0% SETUP, RISE, HOLD UP TIME SETUP, RISE, HOLD UP TIME
SETUP, RISE, HOLD UP TIME 4000ms, 100ms, 30ms / 230VAC4000ms, 100ms, 10ms / 115VAC at full load 4000ms, 100ms, 30ms / 230VAC4000ms, 100ms, 10ms / 115VAC at full load
4000ms, 100ms, 30ms / 230VAC4000ms, 100ms, 10ms / 115VAC at full load VOLTAGE RANGE Note.7 90 ~ 264VAC135 ~ 370VDC VOLTAGE RANGE Note.7 90 ~ 264VAC135 ~ 370VDC
VOLTAGE RANGE Note.7 90 ~ 264VAC135 ~ 370VDC INPUT INPUT
INPUT FREQUENCY RANGE EFFICIENCY (Typ.) FREQUENCY RANGE EFFICIENCY (Typ.)
FREQUENCY RANGE EFFICIENCY (Typ.) 47 ~ 63Hz 47 ~ 63Hz
47 ~ 63Hz 80% 80%
80%82% 82%
82%84% 84%
84%84%85%85%85.5% 84%85%85%85.5%
84%85%85%85.5%PROTECTION PROTECTION
PROTECTION AC CURRENT AC CURRENT
AC CURRENT INRUSH CURRENT (max.) LEAKAGE CURRENT (max.) INRUSH CURRENT (max.) LEAKAGE CURRENT (max.)
INRUSH CURRENT (max.) LEAKAGE CURRENT (max.) OVERLOAD OVERLOAD
OVERLOADOVER VOLTAGE WORKING TEMP. OVER VOLTAGE WORKING TEMP.
OVER VOLTAGE WORKING TEMP. WORKING HUMIDITY WORKING HUMIDITY
WORKING HUMIDITY 0.4A / 100VAC 0.25A / 230VAC 0.4A / 100VAC 0.25A / 230VAC
0.4A / 100VAC 0.25A / 230VAC COLD START 40A / 100VAC80A / 230VAC COLD START 40A / 100VAC80A / 230VAC
COLD START 40A / 100VAC80A / 230VAC 0.25mA / 240VAC 0.25mA / 240VAC
0.25mA / 240VAC 110% ~ 200%rated output power 110% ~ 200%rated output power
110% ~ 200%rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed Protection type : Hiccup mode, recovers automatically after fault condition is removed
Protection type : Hiccup mode, recovers automatically after fault condition is removed 115% ~ 135%rated output voltage 115% ~ 135%rated output voltage
115% ~ 135%rated output voltage Protection type : Clamp by zener diode Protection type : Clamp by zener diode
Protection type : Clamp by zener diode -10 ~ +50 (Refer to "Derating Curve") -10 ~ +50 (Refer to "Derating Curve")
-10 ~ +50 (Refer to "Derating Curve") 20% ~ 90% RH non-condensing 20% ~ 90% RH non-condensing
20% ~ 90% RH non-condensing ENVIRONMENTSTORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION ENVIRONMENTSTORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION
ENVIRONMENTSTORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS SAFETY STANDARDS
SAFETY STANDARDS -20 ~ +85, 10 ~ 95% RH -20 ~ +85, 10 ~ 95% RH
-20 ~ +85, 10 ~ 95% RH 0.03% /(0 ~ 30) 0.03% /(0 ~ 30)
0.03% /(0 ~ 30) 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes UL60950-1, CSA C22.2, TUV EN60950 -1, AS/NZS 60950.1, CCC GB4943 approved UL60950-1, CSA C22.2, TUV EN60950 -1, AS/NZS 60950.1, CCC GB4943 approved
UL60950-1, CSA C22.2, TUV EN60950 -1, AS/NZS 60950.1, CCC GB4943 approved SAFETY & EMC SAFETY & EMC
SAFETY & EMC (Note. 8) (Note. 8)
(Note. 8)OTHERS OTHERS
OTHERS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION
WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION EMC IMMUNITY LIFE EMC IMMUNITY LIFE
EMC IMMUNITY LIFE MTBF MTBF
MTBF DIMENSION DIMENSION
DIMENSION I/P-O/P:4242VDC I/P-O/P:4242VDC
I/P-O/P:4242VDC I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH
I/P-O/P:100M Ohms / 500VDC / 25/ 70% RH Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254, GB17625.1 Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254, GB17625.1
Compliance to EN55022, EN61000-3-2,3, FCC part15, GB9254, GB17625.1 Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A
Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A 2 years : 100% load 30, 8 hours / day 2 years : 100% load 30, 8 hours / day
2 years : 100% load 30, 8 hours / day 100Khrs min.MIL-HDBK-217F (25) 100Khrs min.MIL-HDBK-217F (25)
100Khrs min.MIL-HDBK-217F (25) 70.7*40*38.8mm (L*W*H) 70.7*40*38.8mm (L*W*H)
70.7*40*38.8mm (L*W*H) PACKING97g ; 50pcs / 6.3kg / CARTON PACKING97g ; 50pcs / 6.3kg / CARTON
PACKING97g ; 50pcs / 6.3kg / CARTON DC OUTPUT PLUG DC OUTPUT PLUG
DC OUTPUT PLUG See page 2; Other type available by customer requested See page 2; Other type available by customer requested
See page 2; Other type available by customer requested CONNECTOR CONNECTOR
CONNECTOR CABLE CABLE
CABLE See page 2; Other type available by customer requested See page 2; Other type available by customer requested
See page 2; Other type available by customer requestedNOTE NOTE
NOTE 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient.
1.All parameters are specified at 230VAC input, rated load, 25 70% RH ambient. 2.DC voltage:The output voltageset at point measure by plug terminal& 50% load. 2.DC voltage:The output voltageset at point measure by plug terminal& 50% load.
2.DC voltage:The output voltageset at point measure by plug terminal& 50% load. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor. 4.Tolerance: includes set up tolerance, line regulation, load regulation. 4.Tolerance: includes set up tolerance, line regulation, load regulation.
4.Tolerance: includes set up tolerance, line regulation, load regulation. 5.Line regulation is measured from low line to high line at rated load. 5.Line regulation is measured from low line to high line at rated load.
5.Line regulation is measured from low line to high line at rated load. 6.Loadregulation is measured from 10% to 100% ratedload 6.Loadregulation is measured from 10% to 100% ratedload
6.Loadregulation is measured from 10% to 100% ratedload 7.Derating may be needed under low input voltage. Please check the derating curve for more details. 7.Derating may be needed under low input voltage. Please check the derating curve for more details.
7.Derating may be needed under low input voltage. Please check the derating curve for more details. 8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the 8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the
8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to performthese EMC tests, please refer to "EMI testingof component powersupplies." EMC directives. For guidance on how to performthese EMC tests, please refer to "EMI testingof component powersupplies."
EMC directives. For guidance on how to performthese EMC tests, please refer to "EMI testingof component powersupplies." (asavailable on http://www.meanwell.com) (asavailable on http://www.meanwell.com)
(asavailable on http://www.meanwell.com) 9.Main body unit and AC inlet plug should be ordered separately ; it needs to be used along with any of the AC inlet plug. 9.Main body unit and AC inlet plug should be ordered separately ; it needs to be used along with any of the AC inlet plug.
9.Main body unit and AC inlet plug should be ordered separately ; it needs to be used along with any of the AC inlet plug. File Name:GE12-SPEC2015-09-15 File Name:GE12-SPEC2015-09-15
File Name:GE12-SPEC2015-09-15

Datasheet - PDF

Title:Language:Size:Type:
pdf-Input: 90-264 AC / 135-370 DC, Output: 1, V1: 24, A1: 0,625 - MEANWELL - GE12I24-P1J - GE12I24P1JEnglish180 Kbytespdf-Input: 90-264 AC / 135-370 DC, Output: 1, V1: 24, A1: 0,625 - MEANWELL - GE12I24-P1J - GE12I24P1J

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or