51ADX0030B
ADX0030B
LOVATO ELECTRIC
1
SOFT STARTER, ADX TYPE, FOR SEVERE DUTY (STARTING CURRENT 5•IE). WITH INTEGRATED BY-PASS CONTACTOR, 30A
ADX static starter. B with built-in by-pass (Severe Applications, starting current = 5Ie) 30A
Soft starter, ADX... type, for severe duty (starting current 5•Ie). With integrated bypass contactor, 30A
Soft Starters / Starters Static - LOVATO ELECTRIC
* Brand new product in its original packaging covered by the warranties and certifications provided by LOVATO ELECTRIC
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Order code | 51ADX0030B |
Weight [g] | 9240 |
Qty. per package | 1 |
Multiple qty. of packs per order | 1 |
Package dimensions [mm] | 385X165X240 |
Volume [cm³] | 15246 |
Bar code [EAN13] | 8013975063804 |
HS Code | 85371098 |
Product designation | Soft starter | |||
Product type designation | ADX…B | |||
Motor type | Asynchronous three phase | |||
Electrical features | ||||
Supplies voltage | ||||
Type of system | Three phase | |||
Rated supply voltage | V | 208…500VAC | ||
auxiliary supply voltage (Us) | 208…240VAC | |||
Rated frequency | Hz | 50/60 | ||
Rated starter current Ie | A | 30 | ||
Rated motor power | ||||
IEC ratings (T≤40°C) | ||||
230VAC | kW | 7.5 | ||
400VAC | kW | 15 | ||
500VAC | KW | 18.5 | ||
UL ratings (T≤40°C) | ||||
220-240VAC | HP | 10 | ||
380-415VAC | HP | 15 | ||
440-480VAC | HP | 20 | ||
Number of controlled phases | Nr. | 3 | ||
Built-in bypass | Yes | |||
Cooling System | Natural | |||
Programming interface | ||||
Display | Backlit LCD 2x16 character | |||
Programming with NFC technology | No | |||
Optical port | No | |||
Startup and stop settings | ||||
Startup method | Torque or voltage ramp with current limitation | |||
Stop method | Torque ramp, voltage ramp, free-wheel stop | |||
Braking method | DC dynamic with external relay | |||
Protections | ||||
Auxiliary supply protection | Voltage too low | |||
Power supply Protection | No power, phase loss, phase sequence, frequency out of limits, minimum and maximum voltage | |||
Motor protection | Overload at starting (trip class 2, 10A, 10, 15, 20, 25, 30, 35 and 40), overload during running (trip class 2, 10A, 10, 15, 20, 25 and 30), locked rotor, current asymmetry, minimum torque (dry run), overtemperature , starting too long | |||
Starter protection | Overcurrent, overtemperature, bypass failure, phase shorted, temperature sensor fault, maintenance request | |||
Input and Output | ||||
Digital inputs | ||||
Number of digital input | Nr. | 3 (2 digital inputs + 1 digital/analog input) | ||
Digital input type | 24VDC (no need for external feeder) | |||
Digital input functions | 1 input for start, 1 input programmable (stop, free-wheel stopping, external alarm, motor preheat, local control, alarms inhibit, manual resetting of motor thermal protection, keypad lock, second motor), 1 input programmable multifunction (OFF, free-wheel | |||
Analog inputs | ||||
Number of analog input | Nr. | 1 (digital/analog) | ||
Analog input type | 0-10VDC (0-20mA with external resistor 500Ω) | |||
Analog input functions | Motor protection via PTC probes, acceleration and/or deceleration ramp via analog input, analog input thresholds for motor starting and stopping, analog input thresholds for programmable relay enable and disable, PT100 input thresholds for motor starting a | |||
Digital outputs | ||||
Number of digital output | Nr. | 4 | ||
Digital output arrangement | 3 x 1 NO (SPST) + 1 C/O (SPDT)Ratings: 5A 250VAC AC1, 2A 250VAC AC15 | |||
Digital output functions | C/O output for global alarm, 3 x 1NO outputs programmable (OFF, motor powered, up to speed, braking, current limit, service required, cascade starting, programmable input thresholds, alarm Axx) | |||
Analog outputs | ||||
Number of analog output | Nr. | 1 | ||
Analog output type | 0...20mA, 4...20mA (0...10V with external resistor 500Ω) | |||
Analog output functions | Current, torque, motor thermal status, power factor and active power | |||
Ambient conditions | ||||
Temperature | ||||
Operating temperature | ||||
min | °C | -10 | ||
max | °C | +55°C (with current derating >45°C of 1.5%/°C ) | ||
Storage temperature | ||||
min | °C | -30 | ||
max | °C | +70 | ||
Max altitude | m | 1000 without derating (over 1000mt with current derating of 0.5%/100m) | ||
Relative humidity | % | 95% without condensation or dripping | ||
Pollution degree | 3 | |||
Housing | ||||
Mounting | Screw-fixing | |||
IP degree of protection | IP20 | |||
Dimensions (W x H x D) | mm | 157 x 372 x 223 | ||
Weight | Kg | 9.24 | ||
ETIM classification | ||||
ETIM 8.0 | EC000640 - Soft starter |
Title: | Size: | Type: |
---|---|---|
51ADX0030B ADX0030B 05-Soft-starters-05-January-2018_EN.pdf | 1 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.