Product successfully added to your shopping cart
11BG0031A110
BG0031A110
LOVATO ELECTRIC
1
CONTROL RELAY WITH CONTROL CIRCUIT: AC AND DC, BG00 TYPE, AC COIL 50/60HZ, 110VAC, 3NO AND 1NC
Auxiliary Minicontactor 10A 3 NA 1 NC Coil 110V AC
Industrial Contactors and Accessories - LOVATO ELECTRIC
* Brand new product in its original packaging covered by the warranties and certifications provided by LOVATO ELECTRIC
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
Order code | 11BG0031A110 |
Weight [g] | 179 |
Qty. per package | 1 |
Multiple qty. of packs per order | 1 |
Package dimensions [mm] | 060X045X060 |
Volume [cm³] | 162 |
Bar code [EAN13] | 8013975080504 |
HS Code | 85365080 |
Product designation | Auxiliary contactor | |||
Product type designation | BG00 | |||
Contact characteristics | ||||
Number of poles | nr. | 4 | ||
Rated insulation voltage Ui IEC/EN | V | 690 | ||
Rated impulse withstand voltage Uimp | kV | 6 | ||
Operational frequency | ||||
min | Hz | 25 | ||
max | Hz | 400 | ||
IEC Conventional free air thermal current Ith | A | 10 | ||
Operational current Ie | ||||
AC-1 (≤40°C) | A | 160 | ||
Short-time allowable current for 10s (IEC/EN60947-1) | A | 0 | ||
Protection fuse | ||||
gG (IEC) | A | 16 | ||
Tightening torque for terminals | ||||
min | Nm | 0.8 | ||
max | Nm | 1 | ||
min | Ibin | 0.6 | ||
max | Ibin | 0.7 | ||
Tightening torque for coil terminal | ||||
min | Nm | 0.8 | ||
max | Nm | 1 | ||
min | Ibft | 0.59 | ||
max | Ibft | 0.74 | ||
Max number of wires simultaneously connectable | nr. | 2 | ||
Conductor section | ||||
Flexible w/o lug conductor section | ||||
min | mm² | 0.8 | ||
max | mm² | 2.5 | ||
Flexible c/w lug conductor section | ||||
min | mm² | 1.5 | ||
max | mm² | 2.5 | ||
Flexible with insulated spade lug conductor section | ||||
min | mm² | 1.5 | ||
max | mm² | 2.5 | ||
Power terminal protection according to IEC/EN 60529 | IP20 | |||
Mechanical features | ||||
Operating position | ||||
normal | Vertical plan | |||
allowable | ±30° | |||
Fixing | Screw / DIN rail 35mm | |||
Weight | g | 200 | ||
Auxiliary contact characteristics | ||||
Type of contact | 3 NO + 1 NC | |||
Thermal current Ith | A | 10 | ||
IEC/EN 60947-5-1 designation | A600 - Q600 | |||
Operating current AC15 | ||||
230V | A | 3 | ||
400V | A | 1.9 | ||
500V | A | 1.4 | ||
Operating current DC12 | ||||
110V | A | 2.9 | ||
Operating current DC13 | ||||
24V | A | 2.9 | ||
48V | A | 1.4 | ||
60V | A | 1.2 | ||
110V | A | 0.6 | ||
125V | A | 0.55 | ||
220V | A | 0.3 | ||
600V | A | 0.1 | ||
Operations | ||||
Mechanical life | cycles | 20000000 | ||
Safety related data | ||||
Performance level B10d according to EN/ISO 13489-1 | ||||
mechanical load | cycles | 20000000 | ||
Mirror contats according to IEC/EN 609474-4-1 | YES | |||
EMC compatibility | YES | |||
AC coil operating | ||||
Rated AC voltage at 50/60Hz | V | 110 | ||
AC operating voltage | ||||
of 50/60Hz coil powered at 50Hz | ||||
pick-up | ||||
min | %Us | 75 | ||
max | %Us | 115 | ||
drop-out | ||||
min | %Us | 20 | ||
max | %Us | 55 | ||
of 50/60Hz coil powered at 60Hz | ||||
pick-up | ||||
min | %Us | 80 | ||
max | %Us | 115 | ||
drop-out | ||||
min | %Us | 20 | ||
max | %Us | 55 | ||
AC average coil consumption at 20°C | ||||
of 50/60Hz coil powered at 50Hz | ||||
in-rush | VA | 30 | ||
holding | VA | 4 | ||
of 50/60Hz coil powered at 60Hz | ||||
in-rush | VA | 25 | ||
holding | VA | 3 | ||
of 60Hz coil powered at 60Hz | ||||
in-rush | VA | 30 | ||
holding | VA | 4 | ||
Dissipation at holding ≤20°C 50Hz | W | 0.9 | ||
Max cycles frequency | ||||
Mechanical operation | cycles/h | 3600 | ||
Operating times | ||||
Average time for Us control | ||||
in AC | ||||
Closing NO | ||||
min | ms | 12 | ||
max | ms | 21 | ||
Opening NO | ||||
min | ms | 9 | ||
max | ms | 18 | ||
Closing NC | ||||
min | ms | 17 | ||
max | ms | 26 | ||
Opening NC | ||||
min | ms | 7 | ||
max | ms | 17 | ||
in DC | ||||
Closing NO | ||||
min | ms | 18 | ||
max | ms | 25 | ||
Opening NO | ||||
min | ms | 2 | ||
max | ms | 3 | ||
Closing NC | ||||
min | ms | 3 | ||
max | ms | 5 | ||
Opening NC | ||||
min | ms | 11 | ||
max | ms | 17 | ||
UL technical data | ||||
General USE | ||||
Contactor | ||||
AC current | A | 160 | ||
Contact rating of auxiliary contacts according to UL | A600 - Q600 | |||
Ambient conditions | ||||
Temperature | ||||
Operating temperature | ||||
min | °C | -50 | ||
max | °C | +70 | ||
Storage temperature | ||||
min | °C | -60 | ||
max | °C | +80 | ||
Max altitude | m | 3000 | ||
Resistance & Protection | ||||
Pollution degree | 3 | |||
ETIM classification | ||||
ETIM 8.0 | EC000196 - Contactor relay |
Title: | Size: | Type: |
---|---|---|
11BG0031A110 BG0031A110 02-Contactors-02-January-2018_EN.pdf | 6 Mbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.