730821 GENERAL ELECTRIC Switch-disconnector-fuse Fulos 000 NF 22 x 58 125A 3P View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

730821 GENERAL ELECTRIC Switch-disconnector-fuse Fulos 000 NF 22 x 58 125A 3P

730821

GENERAL ELECTRIC

Available

Ship on today

Switch-disconnector-fuse Fulos 000 NF 22 x 58 125A 3P

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Industrial

DIFFERENTIAL PROTECTION

* Brand new produt in its original packing covered by the warranties and certifications provided by GENERAL ELECTRIC

QuantityPrice
1+$113.29
2+$110.39
3+$108.96
4+$108.05
5+$107.67
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Fulos 000 NF - 125A

Performance

  • Panel mounting
  • Fused-safety-switch-disconnector (main disconnector)
  • Disconnect function
  • Transparent cover
  • Quick make and quick break mechanism
  • Independent opening and closing
  • Positive contact indication (PCI)
  • Very low power losses
  • Fuse completely disconnected in "OFF"
  • Defeat mechanism rotary handle
  • Double knife contacts - high short-circuit resistance
  • Number of poles 3P - 4P

Standards
  • For disconnectors
    IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107, BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130
    Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1
  • For fuses
    IEC 60269-2-1, BS 88 Parts 1 & 2 1988, DIN VDE 0636 Teil 1,NF EN 60269-1, NF C 63-211, NF C 63-210

SPECIFICATIONS

Series Switch-disconnector-fuses - FULOS
Conventional enclosed thermal current Ithe = Ith 125 A
Number of poles 3P
Type of fuse NF
Type of disconnector Switch-disconnector-fuse
Contact position indication Positive contact position indication
Mounting Panel mounting
Type of Dilos/Fulos FULOS 000
400/415V (AC23A/AC23B) 125 A
500V (AC23A/AC23B) 100 A
690V (AC23A/AC23B) 80 A
400/415V (AC22A/AC22B) 125 A
500V (AC22A/AC22B) 125 A
690V (AC22A/AC22B) 125 A
400/415V (AC21A/AC21B) 125 A
500V (AC21A/AC21B) 125 A
690V (AC21A/AC21B) 125 A
110V (DC23A 2P) 100 A
250V (DC23A 2P) 63 A
250V (DC23A 4P) 100 A
Rated operational voltage Ue (V) 690 V
Rated impulse withstand voltage (2000 m) Uimp 8 kV
Standards BS88part21988;BSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0636Teil1;DINVDE0660Teil1;IEC60269-2-1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63-210;NFC63130;NFC63211;NFEN60269-1
Approvals KEMA
Conventional enclosed thermal current lthe 125 A
Maximum torque on terminals (Nm) 12 Nm
Rated insulation voltage Ui (V) 1000 V
Durability (number of operational cycles) electrical 3000
Max Rated Operational Power 400/415V (AC23 (kW)) 69 kW/72 kW
Max Rated Operational Power 500V (AC23 (kW)) 86 kW
Max Rated Operational Power 690V (AC23 (kW)) 45 kW
Rated capacity power at 400V (kVAR) 60 kVAr
Durability (number of operational cycles) mech. (min.) 10000
Terminal capacity (Cu) min/max (mm²) 6 mm²/50 mm²
Rated Cond S/C current Backup protection kA rms @ 400V 50 kA
Rated Cond S/C current Backup protection kA rms @ 415V 50 kA
Rated Cond S/C current Backup protection kA rms @ 500V 50 kA
Rated Cond S/C current Backup protection kA rms @ 690V 33 kA

DIMENSIONS

Weight 1.2 kg

CLASSIFICATION

ETIM 5.0EC001040
ETIM 6.0EC001040

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or