730985 GENERAL ELECTRIC Switch-disconnector Dilos 00 16A 3P Door mounting View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

730985 GENERAL ELECTRIC Switch-disconnector Dilos 00 16A 3P Door mounting

730985

GENERAL ELECTRIC

Available

Ship on today

Switch-disconnector Dilos 00 16A 3P Door mounting

More details


Residual Current Devices Rcd Ground Fault Circuit Interrupter Gfci Breaker Rccb

Industrial

DIFFERENTIAL PROTECTION

* Brand new produt in its original packing covered by the warranties and certifications provided by GENERAL ELECTRIC

QuantityPrice
1+$22.71
7+$20.62
13+$20.18
19+$19.94
25+$19.79
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Dilos 00 - 16A up to 40A

Performance

  • DIN-rail type
  • Disconnect function
  • Complete range of add-on devices
  • Double knife contacts
  • Number of poles 2P - 3P - 4P
  • Mounting
    • DIN-rail / Panel
    • Wall
  • Box terminals
  • Padlockable

Standards

IEC 60947-1 and IEC 60947-3, DIN VDE 0660 Teil 107,BS EN 60947-3, CEI 17-11 (Fasc. 1039), EN 60947-3, NBN EN 60947-3, NF C 63-130 Safety-switch-disconnector (red/yellow) according to DIN VDE 0113 Teil 1

SPECIFICATIONS

Series Switch-disconnectors - DILOS
Conventional enclosed thermal current Ithe = Ith 16 A
Number of poles 3P
Type of disconnector Switch-disconnector
Contact position indication Positive contact position indication
Mounting Door mounting
Type of Dilos/Fulos DILOS 00
400/415V (AC23A/AC23B) 16 A
500V (AC23A/AC23B) 16 A
690V (AC23A/AC23B) 16 A
400/415V (AC22A/AC22B) 16 A
500V (AC22A/AC22B) 16 A
690V (AC22A/AC22B) 16 A
400/415V (AC21A/AC21B) 16 A
500V (AC21A/AC21B) 16 A
690V (AC21A/AC21B) 16 A
110V (DC23A 2P) 16 A
250V (DC23A 2P) 16 A
Rated operational voltage Ue (V) 690 V
Rated impulse withstand voltage (2000 m) Uimp 8 kV
Standards BSNBNEN60947-3;CEI17-11(Fasc.1039);DINVDE0660Teil1;IEC60947-1;IEC60947-3;K63B;NBNEN60947-3;NFC63130
Approvals KEMA
Conventional enclosed thermal current lthe 16 A
Maximum torque on terminals (Nm) 2.2 Nm
Rated insulation voltage Ui (V) 690 V
Durability (number of operational cycles) electrical 3000
Max Rated Operational Power 400/415V (AC23 (kW)) 7.5 kW/7.5 kW
Max Rated Operational Power 500V (AC23 (kW)) 7.5 kW
Max Rated Operational Power 690V (AC23 (kW)) 11 kW
Rated short circuit making cap Icm (kA peak) Ue = 400V 4.5 kA
Rated short circuit making cap Icm (kA peak) Ue = 415V 4.5 kA
Rated short circuit making cap Icm (kA peak) Ue = 500V 3 kA
Rated short circuit making cap Icm (kA peak) Ue = 690V 3 kA
Rated short time withstand current Icw (kA rms) 1 s 1 kA
Durability (number of operational cycles) mech. (min.) 40000
Terminal capacity (Cu) min/max (mm²) 1.5 mm²/16 mm²
Rated Cond S/C current Backup protection kA rms @ 400V 50 kA
Rated Cond S/C current Backup protection kA rms @ 415V 50 kA
Rated Cond S/C current Backup protection kA rms @ 500V 50 kA
Rated Cond S/C current Backup protection kA rms @ 690V 50 kA

DIMENSIONS

Weight 0.125 kg

CLASSIFICATION

ETIM 5.0EC000216
ETIM 6.0EC000216

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or