MT+CT1000-Current Transformer 1000/5A

More details

Energy Meters Control Analizers



* Brand new produt in its original packing covered by the warranties and certifications provided by GENERAL ELECTRIC

Price: $41.54
*This price is per unit and is the net value (not including taxes if applicable).
Up to 35% discount for registered clients.

Request a quote
How it Works

How does the quotation request work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with our price proposals
4 You can directly process the order for the quotation

There are several options for payment
- Credit card
- Wire Transfer
- PayPal

More info

Current transformers - Series MT+CT

  • Function:
    When current in a circuit is too high to apply directly to measuring instruments, a current transformer produces a reduced current accurately proportional to the current in the circuit, which can be conveniently connected to measuring and recording instruments.
    A current transformer isolates the measuring instruments from what may be very high Current in the monitored circuit.

  • Applications:
    Current transformers are commonly used in metering.

  • Features:
    Current transformers are used extensively for measuring current. This new CTs range covers every facility with three-phase service and single-phase services greater from 40A to 4000A.
    The CT is typically described by its current ratio from primary to secondary.
    Often, multiple CTs are installed for various uses. For example, protection devices and revenue metering may use separate CTs to provide isolation between metering and protection circuits, and allows current transformers with different characteristics (accuracy, overload performance) to be used for the devices. The primary circuit is largely unaffected by the insertion of the CT. The rated secondary current is commonly standardized at 5A. For example, a 4000:5 CT secondary winding will supply an output current of 5 Amperes when the primary winding current is 4000 A.
    The load, or burden, of the CT should be a low resistance. The accuracy of a CT is directly related to a number of factors including: burden, burden class/saturation class, rating factor, load and physical configuration for the IEC standard, accuracy classes for various types of measurement are set out in IEC 60044-1, Classes 0.5, 1 and 3.The class designation is an approximate measure of the CTs accuracy.
    The ratio (primary to secondary current) error of a Class 1 CT is 1% at rated current; the ratio error of a Class 0.5 CT is 0.5% or less.


Status Active


Series Current transformer
Range Current transformer
Scale 1000/5 A
Standard packing 1
Rated current In 1000 A
Frequency 47 - 63Hz
Operating temperature range -25°C / +50°C
Terminal capacity max (mm²) 6 mm²


Weight 0.32 kg


ETIM 5.0EC002048
ETIM 6.0EC002048