CS-66/300 111700 EATON MOELLER Wall enclosure, +mounting plate, HxWxD 600x600x300mm View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

CS-66/300 111700 EATON MOELLER Wall enclosure, +mounting plate, HxWxD 600x600x300mm

CS-66/300

111700

EATON - MOELLER

Available

Ship on today

Wall enclosure, +mounting plate, HxWxD=600x600x300mm

More details


Control Cabinets Switch Boxes Distribution Enclosures

Enclosures- EATON - MOELLER

CS Accessories - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$199.45
2+$194.75
3+$192.42
4+$191.85
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Wall-mounting housing CS
Product function
  Wall-mounting housing with mounting plate
Degree of Protection
  IP66
IP23 (with ventilating plates)
Description
  Foamed polyurethane sealing throughout.
Impact resistance category IK09 to EN 62262.
Sheet steel mounting plate
Bottom plate with foamed gasket.
Single door, door stop on the right, door opening angle 120°
Door hinge pins with quick change technology.
Standardized locking system with sash fastener.
Powder coating RAL 7035 inside and outside
Material
  Steel plate
Dimensions
   
Width
 mm600
Height
 mm600
Depth
 mm300
Locks
Number 2
Hinges
Number 2
Door profile molding
Number 2
Flange plates
Width x Depthmm172 x 532
Max. F3A flanges
Number 2
Mounting plates
   
Height
 mm570
Width
 mm550
Weight
 kg24.5
Information about equipment supplied
  Lock, 3 mm double ward key
Including M6 threaded welded studs for earth conductor connections in the door
Technical data
General
Standards
  IEC/EN 60529, IEC 62262, IEC/EN 62208
RoHS
  In accordance with Directive 2002/95/EC of the European Parliament and Council
RoHS (in accordance with Directive 2002/95/EC of the European Parliament and Council)
  yes
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclical, to IEC 60068-2-30
Ambient temperature
 °C-40 - +70
Degree of Protection
  IP66
IP23 (with ventilating plates)
Installation conditions
  Indoor-/outdoor installation
Power loss
   
 
  Power loss Pv [W] for fully enclosed sheet steel enclosure CS without internal partitions for wall mounting.
Example: max. ambient temperature 35°C; Overtemperature ΔT = 20 K; Relative humidity = 75%.
Max. heat dissipation
   
Individual enclosure for wall mounting
PVW65
Starting enclosure for wall mounting
PVW61
Middle enclosure for wall mounting
PVW57
Material characteristics
Material
  Steel plate
Surface treatment
  Structured powder spray polyester based paint finish
Surface finish
  Semi-textured
Colour
  RAL 7035, light grey
Finish
  Gloss
Material thickness
 mm 
Body
 mm1.5
Mounting plate
 mm2
Door
 mm1.5
Bottom plate
 mm1.5
Material properties
Mechanical
   
Impact resistance
  IK09 according to EN 62262
max. assembly weights
   
Total of Weight of fitted components
 kg275
Mounting plate
 kg250
Door
 kg25
 
  500 kg payload, when brackets fitted in all four enclosure corners (vertically or horizontally) and the weights are symmetrically distributed within the enclosure.
Description/standard features
Construction
  Canted and seam welded, including two M6 threaded bolts for earth conductor connections inside the enclosure.
Back plate
  9 mm drilling dimensions for wall mounting
Side plates
  Without apertures
Top plate
  Without apertures
Bottom plate
  Enclosed, foamed gasket, can be unscrewed for F3A-… flanges or for assembly by user
Mounting plate, material
  Sheet steel, hot-galvanized
Door, Engineering
  Including M6 threaded welded studs for earth conductor connections in the door:
Information about equipment supplied
  Lock, 3 mm double ward key
Including M6 threaded welded studs for earth conductor connections in the door
 
  If electrical apparatus is to be installed in the door, a continuous, permanent protective ground contactor connection must be established with a protective ground cable. The threaded welded studs on the door and on the cabinet side wall must be used as connecting points for the ground leads.
Door hinges
  On the right, can be converted by user
Type Door
  Door hinges right
can be converted by user
door opening angle
  120°
Door interlock
  Protection insulated turn-buckle
Standard closure 3 mm double-ward key
Locks
Number 2
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Heat dissipation, at an ambient temperature of 35°C, delta T: 20 degrees, calculated as per IEC 60890
   
Individual enclosure for wall mounting
PVCO65
Starting enclosure for wall mounting
PVCO61
Middle enclosure for wall mounting
PVCO57
Heat dissipation, at an ambient temperature of 35°C, delta T: 35 degrees, calculated as per IEC 60890
   
Individual enclosure for wall mounting
PVCO131
Starting enclosure for wall mounting
PVCO123
Middle enclosure for wall mounting
PVCO115
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply to enclosures without lifting aids.
10.2.6 Mechanical impact
  IK09
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  IP66_x
10.4 Clearances and creepage distances
  Is the panel builder's responsibility.
10.5 Protection against electric shock
  < 0.1 Ω; meets the product standard's requirements.
10.6 Incorporation of switching devices and components
  Is the panel builder's responsibility.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Ui = 1000 V AC
10.9.3 Impulse withstand voltage
  Does not apply to basic enclosures as defined in EN 62208.
10.9.4 Testing of enclosures made of insulating material
  Does not apply to metal enclosures.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility.
10.13 Mechanical function
  Meets the product standard's requirements.
Approvals
Product Standards  UL 508A; CSA-C22.2 No.14; IEC/EN 60529; CE marking
UL File No.  E336299
UL Category Control No.  NITW
CSA File No.  
CSA Class No.  
North America Certification  Request filed for CSA
Conditions of Acceptability  Series CS may be provided with metal sub-panel. No back mounted components are allowed between sub-panel and the back sheet metal enclosure
Specially designed for North America  No
Suitable for  Industrial Control Panels
Degree of Protection  IEC: IP66, indoor and outdoor; UL/CSA Types 1, 12, indoor only.
Dimensions
>Dimensions
CAD data
>Product-specific CAD data
>3D Preview

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or