VGDILE250 010336 XTMCXVSB EATON ELECTRIC Varistor suppressor, 250VAC, for DILE, screw connection View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

VGDILE250 010336 XTMCXVSB EATON ELECTRIC Varistor suppressor, 250VAC, for DILE, screw connection

VGDILE250

010336

XTMCXVSB

EATON-MOELLER

10

Varistor suppressor, 250VAC, for DILE, screw connection

More details


Low-voltage industrial components > Surge protection module

KDIL Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Quantity Price
10+$10.56
20+$9.35
30+$8.86
40+$8.58
60+$8.40
*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

Often bought together

More info



Varistor suppressor, 250VAC, for DILE, screw connection
Varistor suppressor circuit, Accessories: Suppressor circuit, Description: Varistor suppressor, Actuating voltage: Us 110 - 250 AC V, For use with: DILE...

General specifications
Product name
Eaton Moeller® series DILE Accessory Varistor suppressor circuit
Part no.
VGDILE250
EAN
4015080103363
Product Length/Depth
16 millimetre
Product height
29 millimetre
Product width
33 millimetre
Product weight
0.01 kilogram
Certifications
CSA-C22.2 No. 14-05
UL 508
IEC/EN 60947-4-1
CSA File No.: 012528
UL
UL Category Control No.: NLDX
CSA Class No.: 3211-03
UL File No.: E29096
CSA
CE
Product Tradename
DILE
Product Type
Accessory
Product Sub Type
Varistor suppressor circuit
Features & Functions
Functions
Varistor (voltage-sensitive resistor)
General information
Product category
Accessories
Voltage type
AC
Climatic environmental conditions
Ambient operating temperature - min
-25 °C
Ambient operating temperature - max
50 °C
Magnet system
Rated control supply voltage (Us) at AC, 50 Hz - min
110 V
Rated control supply voltage (Us) at AC, 50 Hz - max
250 V
Rated control supply voltage (Us) at AC, 60 Hz - min
110 V
Rated control supply voltage (Us) at AC, 60 Hz - max
250 V
Rated control supply voltage (Us) at DC - min
0 V
Rated control supply voltage (Us) at DC - max
0 V
Design verification
Equipment heat dissipation, current-dependent Pvid
0 W
Heat dissipation capacity Pdiss
0 W
Heat dissipation per pole, current-dependent Pvid
0 W
Rated operational current for specified heat dissipation (In)
0 A
Static heat dissipation, non-current-dependent Pvs
0 W
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Surge protection module (EC000683)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Contactor (LV) / Component for protective circuit (ecl@ss13-27-37-10-10 [AKF019018])
Function
Varistor (voltage-sensitive resistor)
Voltage type (operating voltage)
AC
Operating voltage AC 50 Hz
110 - 250 V
Operating voltage AC 60 Hz
110 - 250 V
Operating voltage DC
0 - 0 V
With LED indication
No

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.