Product successfully added to your shopping cart
DC1-124D3NN-A20N
169225
EATON-MOELLER
1
Variable frequency drive, 230 V AC, 1-phase, 4.3 A, 0.75 kW, IP20/NEMA 0, FS1
Power XL Frequency Converters
* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER
Thank you for your interest in our products; we hope the delivery time indicated is to your convenience.
While the order is being processed you can select the type of shipment that best suits your needs: 24-hour air express, standard 48-72 hour land, etc.
This item will continue to be available for a limited time only and is being replaced by the following item: 185788, DC1-124D3NN-A20CE1 | |||
Product range | Variable frequency drives | ||
Part group reference (e.g. DIL) | DC1 | ||
Rated operational voltage | Ue | 230 V AC, 1-phase 240 V AC, single-phase | |
Output voltage with Ve | U2 | 230 V AC, 3-phase 240 V AC, 3-phase | |
Mains voltage (50/60Hz) | ULN | V | 200 (-10%) - 240 (+10%) |
Rated operational current | |||
At 150% overload | Ie | A | 4.3 |
Note | Rated operational current at an operating frequency of 16 kHz and an ambient air temperature of +50 °C | ||
Assigned motor rating | |||
Note | for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1at 50 Hz or 1800 min-1at 60 Hz | ||
Note | Overload cycle for 60 s every 600 s | ||
Note | at 230 V, 50 Hz | ||
150 % Overload | P | kW | 0.75 |
150 % Overload | IM | A | 3.2 |
Note | at 220 - 240 V, 60 Hz | ||
150 % Overload | P | HP | 1 |
150 % Overload | IM | A | 4.2 |
Degree of Protection | IP20/NEMA 0 | ||
Interface/field bus (built-in) | OP-Bus (RS485)/Modbus RTU, CANopen® | ||
Fieldbus connection (optional) | SmartWire-DT | ||
Fitted with | 7-digital display assembly | ||
Frame size | FS1 | ||
Connection to SmartWire-DT | yes in conjunction with DX-NET-SWD3 SmartWire DT module |
General | |||
Standards | Specification for general requirements: IEC/EN 61800-2 EMC requirements: IEC/EN 61800-3 Safety requirements: IEC/EN 61800-5-1 | ||
Certifications | CE, UL, cUL, RCM, UkrSEPRO, EAC | ||
Production quality | RoHS, ISO 9001 | ||
Climatic proofing | ρw | % | < 95%, average relative humidity (RH), non-condensing, non-corrosive |
Ambient temperature | |||
operation (150 % overload) | ϑ | °C | -10 - +50 |
Storage | ϑ | °C | -40 - +60 |
Mounting position | Vertical | ||
Altitude | m | 0 - 1000 m above sea level Above 1000 m: 1% derating for every 100 m max. 4000 m | |
Degree of Protection | IP20/NEMA 0 | ||
Protection against direct contact | BGV A3 (VBG4, finger- and back-of-hand proof) | ||
Main circuit | |||
Supply | |||
Rated operational voltage | Ue | 230 V AC, 1-phase 240 V AC, single-phase | |
Mains voltage (50/60Hz) | ULN | V | 200 (-10%) - 240 (+10%) |
Input current (150% overload) | ILN | A | 7.5 |
System configuration | AC supply systems with earthed center point | ||
Supply frequency | fLN | Hz | 50/60 |
Frequency range | fLN | Hz | 48 - 62 |
Mains switch-on frequency | Maximum of one time every 30 seconds | ||
Power section | |||
Function | Variable frequency drive with internal DC link and IGBT inverter | ||
Overload current (150% overload) | IL | A | 6.45 |
max. starting current (High Overload) | IH | % | 175 |
Note about max. starting current | for 2 seconds every 20 seconds | ||
Output voltage with Ve | U2 | 230 V AC, 3-phase 240 V AC, 3-phase | |
Output Frequency | f2 | Hz | 0 - 50/60 (max. 500) |
Switching frequency | fPWM | kHz | 16 adjustable 4 - 32 (audible) |
Operation Mode | U/f control Speed control with slip compensation | ||
Frequency resolution (setpoint value) | Δf | Hz | 0.1 |
Rated operational current | |||
At 150% overload | Ie | A | 4.3 |
Note | Rated operational current at an operating frequency of 16 kHz and an ambient air temperature of +50 °C | ||
Power loss | |||
Heat dissipation at rated operational current Ie=150 % | PV | W | 45.75 |
Efficiency | η | % | 93.9 |
Maximum leakage current to ground (PE) without motor | IPE | mA | < 1 |
Fitted with | 7-digital display assembly | ||
Frame size | FS1 | ||
Motor feeder | |||
Note | for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1at 50 Hz or 1800 min-1at 60 Hz | ||
Note | Overload cycle for 60 s every 600 s | ||
Note | at 230 V, 50 Hz | ||
150 % Overload | P | kW | 0.75 |
Note | at 220 - 240 V, 60 Hz | ||
150 % Overload | P | HP | 1 |
maximum permissible cable length | I | m | screened: 50 screened, with motor choke: 100 unscreened: 75 unscreened, with motor choke: 150 |
Apparent power | |||
Apparent power at rated operation 230 V | S | kVA | 1.71 |
Apparent power at rated operation 240 V | S | kVA | 1.79 |
Braking function | |||
Standard braking torque | max. 30 % MN | ||
DC braking torque | max. 100% of rated operational current Ie,variable | ||
Control section | |||
Reference voltage | Us | V | 10 V DC (max. 10 mA) |
Analog inputs | 2, parameterizable, 0 - 10 V DC, 0/4 - 20 mA | ||
Analog outputs | 1, parameterizable, 0 - 10 V | ||
Digital inputs | 4, parameterizable, max. 30 V DC | ||
Digital outputs | 1, parameterizable, 24 V DC | ||
Relay outputs | 1, parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1) | ||
Interface/field bus (built-in) | OP-Bus (RS485)/Modbus RTU, CANopen® | ||
Assigned switching and protective elements | |||
Power Wiring | |||
Safety device (fuse or miniature circuit-breaker) | |||
IEC (Type B, gG), 150 % | FAZ-B10/1N | ||
UL (Class CC or J) | A | 10 | |
Mains contactor | |||
150 % overload (CT/IH, at 50 °C) | DILM7 DILEM-…+P1DILEM | ||
Main choke | |||
150 % overload (CT/IH, at 50 °C) | DX-LN1-009 | ||
Radio interference suppression filter (external, 150 %) | DX-EMC12-014-FS1 | ||
Note regarding radio interference suppression filter | Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments | ||
Motor feeder | |||
motor choke | |||
150 % overload (CT/IH, at 50 °C) | DX-LM3-005 | ||
Sine filter | |||
150 % overload (CT/IH, at 50 °C) | DX-SIN3-010 |
Product Standards | UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking | ||
UL File No. | E172143 | ||
UL Category Control No. | NMMS, NMMS7 | ||
CSA File No. | UL report applies to both US and Canada | ||
North America Certification | UL listed, certified by UL for use in Canada | ||
Specially designed for North America | No | ||
Suitable for | Branch circuits | ||
Max. Voltage Rating | 1~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) | ||
Degree of Protection | IEC: IP20 |
Low-voltage industrial components (EG000017) / Frequency controller =< 1 kV (EC001857) | |||
Electric engineering, automation, process control engineering / Electrical drive / Static frequency converter / Static frequency converter = < 1 kv (ecl@ss8-27-02-31-01 [AKE177010]) | |||
Mains voltage | V | 200 - 240 | |
Mains frequency | 50/60 Hz | ||
Number of phases input | 1 | ||
Number of phases output | 3 | ||
Max. output frequency | Hz | 500 | |
Rated output voltage | V | 230 | |
Measuring output current | A | 4.3 | |
Output power at rated output voltage | kW | 0.75 | |
Max. output at quadratic load at rated output voltage | kW | 0.75 | |
Max. output at linear load at rated output voltage | kW | 0.75 | |
With control unit | Yes | ||
Application in industrial area permitted | Yes | ||
Application in domestic- and commercial area permitted | Yes | ||
Supporting protocol for TCP/IP | No | ||
Supporting protocol for PROFIBUS | No | ||
Supporting protocol for CAN | Yes | ||
Supporting protocol for INTERBUS | No | ||
Supporting protocol for ASI | No | ||
Supporting protocol for KNX | No | ||
Supporting protocol for MODBUS | Yes | ||
Supporting protocol for Data-Highway | No | ||
Supporting protocol for DeviceNet | No | ||
Supporting protocol for SUCONET | No | ||
Supporting protocol for LON | No | ||
Supporting protocol for PROFINET IO | No | ||
Supporting protocol for PROFINET CBA | No | ||
Supporting protocol for SERCOS | No | ||
Supporting protocol for Foundation Fieldbus | No | ||
Supporting protocol for EtherNet/IP | No | ||
Supporting protocol for AS-Interface Safety at Work | No | ||
Supporting protocol for DeviceNet Safety | No | ||
Supporting protocol for INTERBUS-Safety | No | ||
Supporting protocol for PROFIsafe | No | ||
Supporting protocol for SafetyBUS p | No | ||
Supporting protocol for other bus systems | No | ||
Number of HW-interfaces industrial Ethernet | 0 | ||
Number of HW-interfaces PROFINET | 0 | ||
Number of HW-interfaces RS-232 | 0 | ||
Number of HW-interfaces RS-422 | 0 | ||
Number of HW-interfaces RS-485 | 1 | ||
Number of HW-interfaces serial TTY | 0 | ||
Number of HW-interfaces USB | 1 | ||
Number of HW-interfaces parallel | 0 | ||
Number of HW-interfaces other | 0 | ||
With optical interface | No | ||
With PC connection | Yes | ||
Integrated braking resistance | No | ||
4-quadrant operation possible | No | ||
Type of converter | U converter | ||
Degree of protection (IP) | IP20 | ||
Height | mm | 184 | |
Width | mm | 81 | |
Depth | mm | 124 | |
Relative symmetric net frequency tolerance | % | 5 | |
Relative symmetric net current tolerance | % | 10 |
Title: | Size: | Type: |
---|---|---|
PDF EATON STARTING CONTROLLING MOTORS EN.pdf | 32 Mbytes | |
DC1-124D3NN-A20N 169225 169225_EN.pdf | 249 Kbytes |
No customer reviews for the moment.
Rating: | |
Name: | |
Email: | |
Subject: | |
Text: | |
Do you recommend this product to buy? | |
Add review |
All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.