U-PKZ0(24V50HZ) 073129 EATON MOELLER Undervoltage release, 24V50Hz View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

U-PKZ0(24V50HZ) 073129 EATON MOELLER Undervoltage release, 24V50Hz

U-PKZ0(24V50HZ)

073129

EATON - MOELLER

Available

Ship on today

Undervoltage release, 24V50Hz

More details


Motor Circuit Protectors Protection Breaker

Motor Protective Circuit Breakers PKZ - EATON - MOELLER

Motor-protective circuit-breakers PKZ (Accessories) - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$17.04
7+$15.43
14+$15.05
21+$14.87
28+$14.75
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme
Product range
  Accessories
Accessories
  Undervoltage release
Actuating voltage
  24 V 50 Hz
For use with
  Undervoltage release PKZ0(4), PKE
Voltage type
  Standard voltage
Current actuation
  AC
Contact sequence
  
General
Terminal capacities
 mm2 
Solid or flexible conductor, with ferrule
 mm21 x (0,75 - 2,5)
2 x (0,75 - 2,5)
Solid or stranded
 AWG1 x (18 - 14)
2 x (18 - 14)
Actuating voltage
  24 V 50 Hz
Pick-up-/drop-out voltage
Pick-up voltage
 x Uc0,85 - 1,1
Drop-out voltage
 x Uc0,7- 0,35
Power consumption
AC
   
Pull-in power
Pick-upVA5
Sealing power
SealingVA3
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA0
Heat dissipation per pole, current-dependent
PvidW0
Equipment heat dissipation, current-dependent
PvidW0
Static heat dissipation, non-current-dependent
PvsW0.5
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C55
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Under voltage coil (EC001022)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Undervoltage trip ([email protected] [AKF015010])
Rated control supply voltage Us at AC 50HZ
 V24 - 24
Rated control supply voltage Us at AC 60HZ
 V0 - 0
Rated control supply voltage Us at DC
 V0 - 0
Voltage type for actuating
  AC
Type of electric connection
  Screw connection
Number of contacts as normally open contact
  0
Number of contacts as normally closed contact
  0
Number of contacts as change-over contact
  0
Delayed
  No
Suitable for power circuit breaker
  No
Suitable for off-load switch
  No
Suitable for motor safety switch
  Yes
Suitable for overload relay
  No
Approvals
Product Standards  UL 508; CSA-C22.2 No. 14; IEC60947-4-1; CE marking
UL File No.  E36332
UL Category Control No.  NLRV
CSA File No.  165628
CSA Class No.  3211-05
North America Certification  UL listed, CSA certified
Specially designed for North America  No
Dimensions
IL03402034Z (AWA1210-1945) Motor-protective circuit-breaker, Starter
 
>
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha