NZM4-4-XKA 266837 0004358963 EATON ELECTRIC Tunnel terminal, 4p, 1 switch side, size 4 View larger
Images are for illustrative purposes only. Please refer to data sheet for details.

NZM4-4-XKA 266837 0004358963 EATON ELECTRIC Tunnel terminal, 4p, 1 switch side, size 4

NZM4-4-XKA

266837

0004358963

EATON-MOELLER

Tunnel terminal, 4p, 1 switch side, size 4

NZM4-4-XKA

More details


Low-voltage industrial components > Wiring set for power circuit breaker

Circuit Breakers NZM Accessories

* Brand new product in its original packaging covered by the warranties and certifications provided by EATON-MOELLER

Total price: $368.26
Unit price: $368.26

*This price is per unit and is the net value (not including taxes if applicable).

If our price is not the best, please ask us for a quote. Ask for a quotation

More info



Tunnel terminal, 4p, 1 switch side, size 4
Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: part no. contains parts for a terminal located at top or bottom for 3 or 4 pole switches. A standard with control circuit terminal for 1x0.75-2.5 mm² (18-14 AWG) or 2x0.75-1.5 mm² (18-16 AWG) copper conductors. Can be fitted to circuit-breaker with screw connection. use ferrules with flexible and highly flexible conductors. Cover NZM4(-4)-XKSA must be fitted (included as standard). Can be used for: NZM4-4, N4-4

General specifications
Product name
Eaton Moeller series NZM connection type
Part no.
NZM4-4-XKA
EAN
4015082668372
Product Length/Depth
88 millimetre
Product height
90 millimetre
Product width
212 millimetre
Product weight
3.403 kilogram
Compliances
IEC
RoHS conform
Certifications
IEC 60947
EN 60947
Product Tradename
NZM
Product Type
Accessories
Product Sub Type
Connection type
Delivery program
Type
Accessory
Tunnel terminal
Number of poles
Four-pole
Amperage Rating
≦ 1400 A
Frame
NZM4
Suitable for
Aluminum cable
Copper cable
Four-pole
Used with
NZM4-4, N4-4
Technical Data - Mechanical - Terminals
Terminal capacity (stranded cable)
50 mm² - 240 mm² (4x)
50 mm² - 240 mm² (1x)
Max. 500 AWG/kcmil (4x)
Max. 500 AWG/kcmil (1x)
Design verification as per IEC/EN 61439
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.8 Connections for external conductors
Is the panel builder's responsibility.
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Additional information
Model
Other

Technical data ETIM 9.0

Low-voltage industrial components (EG000017) / Wiring set for power circuit breaker (EC002050)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Wiring set for circuit breaker (ecl@ss13-27-37-04-24 [ACN957016])
Suitable for number of poles
4
Model
Other

Datasheet - PDF

Title: Size: Type:
NZM4-4-XKA 0004358963 266837 EN_266837.pdf 110 Kbytes   NZM4-4-XKA 0004358963 266837 EN_266837.pdf

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review

All ratings we receive from the items we offer are real and verified. A small gesture, but a lot of value. That's why we thank you for that minute you invest in leaving us your opinion and qualification about the products, because it helps us to continue improving and to offer you a service of even higher quality.