PKE-XTUWA-32 138262 EATON MOELLER Trip block, 8-32A, +communication

PKE-XTUWA-32

138262

EATON - MOELLER

Available

Ship on today

Trip block, 8-32A, +communication

More details


Motor Circuit Protectors Protection Breaker

Motor Protective Circuit Breakers PKZ - EATON - MOELLER

Motor-protective circuit-breakers PKE - EATON - MOELLER

* Brand new produt in its original packing covered by the warranties and certifications provided by EATON - MOELLER

QuantityPrice
1+$119.47
3+$114.19
5+$112.27
7+$111.16
9+$110.74
*This price is per unit and is the net value (not including taxes if applicable).

How it Works

How does this work?

1 Add the products of your choice to the shopping cart
2 Enter your contact details and submit your request
3 You will be notified by email with a quotation
4 From the quotation simply finish your order and you will receive the products

There are several options for payment
- Credit card
- Wire Transfer
- PayPal


Related products

More info



Delivery programme

Motor rating

Rated motor current

AC-3

220 V

230 V

240 V

380 V

400 V

415 V

440 V

500 V

660 V

690 V

P

I

I

I

I

I

kW

A

A

A

A

A

Product range
  Accessories
Accessories
  Trip blocks
Basic function
  Motor protection
Motor protection for heavy starting duty
Setting range
   
Overload releases
2.2 8.7 - - - -
3 11.5 - - - -
4 14.8 8.5   - -
5.5 19.6 11.3 10.2 9 -
7.5 26.4 15.2 13.8 12.1 8.8
11 - 21.7 19.8 17.4 12.6
15 - 29.3 26.6 23.4 17
18.5 - - - 28.9 20.9
22 - - - - 23.8
30 - - - - 32
Technical data
General
Standards
  IEC/EN 60947, VDE 0660, UL 508, CSA C 22.2 No. 14
Climatic proofing
  Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Ambient temperature
   
Storage
ϑ°C-40 - +80
Open
 °C-20 - +55
Enclosed
 °C-20 - +40
Direction of incoming supply
  as required
Degree of protection
   
Device
  IP20
Terminations
  IP00
Busbar tag shroud to EN 50274
  Finger- and back-of-hand proof
Mechanical shock resistance half-sinusoidal shock 10 ms to IEC 60068-2-27
 g25
Altitude
 mMax. 2000
Main conducting paths
Rated impulse withstand voltage
UimpV AC6000
Overvoltage category/pollution degree
  III/3
Rated operational voltage
UeV AC690
Rated uninterrupted current = rated operational current
Iu = IeA32
Rated frequency
fHz40 - 60
Maximum operating frequency
 Ops./h 
Max. operating frequency
 Ops/h60
Motor switching capacity
 kArms 
AC-3 (up to 690 V)
 A32
Trip blocks
Temperature compensation
 °C-5 - +40 (to IEC/EN 60947, VDE 0660)
-25 - +55 (operating range)
Temperature compensation residual error for T > 40 °C
  ±55 (Arbeitsbereich)
Setting range of overload releases
  0.25 - 1 x Iu
short-circuit release
  Trip block, fixed: 15.5 x Ir
delayed approx. 60 ms
Short-circuit release tolerance
  ± 20%
Phase-failure sensitivity
  yes
Design verification as per IEC/EN 61439(Show features)(Hide features)
Technical data for design verification
   
Rated operational current for specified heat dissipation
InA32
Heat dissipation per pole, current-dependent
PvidW1.3
Equipment heat dissipation, current-dependent
PvidW3.9
Static heat dissipation, non-current-dependent
PvsW0
Heat dissipation capacity
PdissW0
Operating ambient temperature min.
 °C-25
Operating ambient temperature max.
 °C55
IEC/EN 61439 design verification
   
10.2 Strength of materials and parts
   
10.2.2 Corrosion resistance
  Meets the product standard's requirements.
10.2.3.1 Verification of thermal stability of enclosures
  Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
  Meets the product standard's requirements.
10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects
  Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
  Meets the product standard's requirements.
10.2.5 Lifting
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
  Does not apply, since the entire switchgear needs to be evaluated.
10.2.7 Inscriptions
  Meets the product standard's requirements.
10.3 Degree of protection of ASSEMBLIES
  Does not apply, since the entire switchgear needs to be evaluated.
10.4 Clearances and creepage distances
  Meets the product standard's requirements.
10.5 Protection against electric shock
  Does not apply, since the entire switchgear needs to be evaluated.
10.6 Incorporation of switching devices and components
  Does not apply, since the entire switchgear needs to be evaluated.
10.7 Internal electrical circuits and connections
  Is the panel builder's responsibility.
10.8 Connections for external conductors
  Is the panel builder's responsibility.
10.9 Insulation properties
   
10.9.2 Power-frequency electric strength
  Is the panel builder's responsibility.
10.9.3 Impulse withstand voltage
  Is the panel builder's responsibility.
10.9.4 Testing of enclosures made of insulating material
  Is the panel builder's responsibility.
10.10 Temperature rise
  The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
10.11 Short-circuit rating
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.12 Electromagnetic compatibility
  Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.13 Mechanical function
  The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Technical data ETIM 6.0(Show features)(Hide features)
Low-voltage industrial components (EG000017) / Tripping bloc for power circuit-breaker (EC000617)
Electric engineering, automation, process control engineering / Low-voltage switch technology / Circuit breaker (LV < 1 kV) / Releasing block for circuit breakers ([email protected] [AKF008010])
Overload release current setting
 A8 - 32
Initial value of the undelayed short-circuit release - setting range
 A96
End value adjustment range undelayed short-circuit release
 A384
Rated permanent current Iu
 A32
Number of poles
  3
Short-circuit release function
  Delayed
Approvals
Product Standards  UL 508; CSA-C22.2 No. 14-10; IEC60947-4-1; CE marking
UL File No.  E36332
UL Category Control No.  NLRV
CSA File No.  165628
CSA Class No.  3211-05
North America Certification  UL listed, CSA certified
Specially designed for North America  No
Characteristics
MN03402004Z PKE12, PKE32 and PKE65 motor-protective circuit-breakers; overload monitoring of Ex e motors
 
>>

Datasheet - PDF

Reviews (0)

No customer reviews for the moment.

Add Review
hide form
Rating:
Name:
Email:
Subject:
Text:
  Captcha
  Add review
Have you got any questions?

If you have any questions, you can visit the following links or contact us via email

Please wait





* Required fields

or